100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Edelman Chapters 20-22 | Questions and Answers | 2025 Revised Update | 100% Correct

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
06-05-2025
Written in
2024/2025

tissue equivalent phantom - CORRECT ANSWER-have ultrasound features similar to soft tissue like the speed of sound, attenuation, scattering characteristics, and echogenicity tissue equivalent phantom - CORRECT ANSWER-grayscale is evaluated with the ______ ___________ ________ doppler phantom - CORRECT ANSWER-include a circulation pump which propels a fluid through vessels embedded in a tissue equivalent phantom slice thickness phantom - CORRECT ANSWER-assesses the slice thickness and its effect upon image accuracy edge shadow - CORRECT ANSWER-appears as a hypoechoic region extending along the edge a curved reflector enhancement - CORRECT ANSWER-appears as a hyperechoic region beneath tissues with abnormally low attenuation

Show more Read less
Institution
Edelman Chapters 20-22
Course
Edelman Chapters 20-22









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Edelman Chapters 20-22
Course
Edelman Chapters 20-22

Document information

Uploaded on
May 6, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

Edelman Chapters 20-22

tissue equivalent phantom - CORRECT ANSWER-have ultrasound features similar to
soft tissue like the speed of sound, attenuation, scattering characteristics, and
echogenicity

tissue equivalent phantom - CORRECT ANSWER-grayscale is evaluated with the
______ ___________ ________

doppler phantom - CORRECT ANSWER-include a circulation pump which propels a
fluid through vessels embedded in a tissue equivalent phantom

slice thickness phantom - CORRECT ANSWER-assesses the slice thickness and its
effect upon image accuracy


edge shadow - CORRECT ANSWER-appears as a hypoechoic region extending along
the edge a curved reflector

enhancement - CORRECT ANSWER-appears as a hyperechoic region beneath tissues
with abnormally low attenuation

focal enhancement (focal banding) - CORRECT ANSWER-a side-to-side region of an
image appear brighter than tissues at other depths

mirror image - CORRECT ANSWER-created when sound reflects off of a strong
reflector, and is redirected toward a second structure

artifact - CORRECT ANSWER-error in imaging

reverberation - CORRECT ANSWER-appear on the display as multiple, equally spaced
echoes caused by the bouncing of the sound wave between 2 strong reflectors
positioned parallel to the ultrasound beam

comet tail - CORRECT ANSWER-appears as a solid hyperechoic line directed
downward

shadow - CORRECT ANSWER-hypoechoic or anechoic region extending downward
from a very strong attenuating medium


deeper - CORRECT ANSWER-with mirror image artifact, the artifact is placed _______
than the real structure

, crosstalk - CORRECT ANSWER-a mirror image artifact that appears on a spectral
doppler display

speed error - CORRECT ANSWER-created when a sound wave propagates through a
medium at a speed other than that of a soft issue

split or cut - CORRECT ANSWER-with speed error artifact, structures appear as if they
are _____ or ___

shallow - CORRECT ANSWER-with speed error artifact, when a medium's speed is
faster than soft tissue, reflectors are placed too _______

deep - CORRECT ANSWER-with speed error artifact, when a medium's speed is slower
than soft tissue, reflectors are placed too ____

side lobes - CORRECT ANSWER-lobes created by single crystal transducers

grating lobes - CORRECT ANSWER-lobes created by array transducers

subdicing - CORRECT ANSWER-dividing each PZT element into small pieces

apodization - CORRECT ANSWER-process of differential excitation

refraction - CORRECT ANSWER-occurs when a sound pulse changes direction during
transmission; degrades lateral resolution

slice thickness - CORRECT ANSWER-appears when the beam dimension is greater
than the reflector size; fills in hollow structures, such as cysts

lateral resolution - CORRECT ANSWER-occurs when beam is wider than the distance
between 2 reflectors located side by side or perpendicular to the beam; 2 objects
appear as one

axial resolution - CORRECT ANSWER-created when a long pulse strikes 2 closely
spaced structures, where one is in front of the other, or apparel to the main axis of the
ultrasound beam; only one reflection will appear on image if the structures are closer
than 1/2SPL

multipath - CORRECT ANSWER-created when sound pulses glance off a second
structure on the way to or from the primary reflector; the transmitted path length differs
from the return path length

temporal resolution - CORRECT ANSWER-low frame rates resulting in less accurate
positioning of reflectors in motion

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PatrickKaylian Delaware State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1807
Member since
2 year
Number of followers
1043
Documents
22113
Last sold
2 days ago

3.8

316 reviews

5
147
4
60
3
54
2
15
1
40

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions