Electrical test - journey man Exam questions With Correct Answers ._____ means must be marked to indicate their purpose - ANSWER-disconnecting .(true/false) a NEMA 4 enclosure protects against corrosive agents - ANSWER-false .(true/false) as long as illumination is provided by some other source a separate luminaire is not required for service equipment - ANSWER-true .(true/false) it is beneficial to have a conductor with a temperature rating higher than the terminal it is connected to because you can use the higher ampacity when derating - ANSWER-true .#18 fixture wire is considered to be protected by a 20 amp branch breaker if it is not over ___ ft long - ANSWER-50 .a 20 amp branch circuit requires #12 conductors but you may tap off of the #12's with #14's to feed a lighting outlet as long as the tap is not over ___ inches long - ANSWER-18 .a 20 amp circuit with two or more receptacle outlets may use ___ or ___ amp rated recptacles - ANSWER-15, 20 .a bathroom receptacle outlet must be put on a ___ ample circuit - ANSWER-20 .a circuit breaker marked 120/240 volts means that it is only approved for _____ systems where the voltage to ground is not over _____ - ANSWER-grounded 120v .a circuit breaker used to switch fluorescent lighting must be marked ____ of _____ - ANSWER-SWP, HID .a concrete encased electrode must consist of at least ___ft of ___ inches rebar, or #___ bare copper - ANSWER-20 1/2 4 .a conductor encased within material of composition or thickness that is not recognized by this code as insulation is called a ____ conductor - ANSWER-covered .a dwelling three stall garage requires at least _ receptacle outlets - ANSWER-3 .a dwelling unit must have at least one ___ amp laundry circuit - ANSWER-20 .a fastened in place appliance on a circuit with two or more outlets may not take up more than ___% of the circuit rating - ANSWER-50 .a foyer requires a receptacle outlet if it is ___ sq ft or more. one is required on each wall space that is____ ft or wider - ANSWER-60, 3 .a ground ring must consist of at least __ ft of #__ bare copper and must be buried at least __ inches deep - ANSWER-20 2 30in .a hallway requires a receptacle outlet if it is ___ ft or longer - ANSWER-10 .a lock nut on an emt connector is not considered to be adequate bonding if you encounter concentric knockouts and the voltage is over ___ to ground - ANSWER-250 .a multiwire circuit must have disconnect that will disconnect all _________ conductors simultanelously - ANSWER-ungrounded .a multiwire circuit shall be permitted to be considered as _____ circuits - ANSWER-multiple .a premises that has two different electrical systems in it must have the ungrounded conductors from each system identified by ____ and ______ - ANSWER-phase, system .a rod or pipe electrode must consist of ___ ft of at least ___ inches pipe or ___ inches rod unless listed or other diameters - ANSWER-8 3/4 5/8 .a single family dwelling requires at least __ outdoor receptacle outlet(s) - ANSWER-2

Content preview

Electrical test - journey man Exam questions With
Correct Answers
._____ means must be marked to indicate their purpose - ANSWER-
disconnecting


.(true/false) a NEMA 4 enclosure protects against corrosive agents - ANSWER-
false


.(true/false) as long as illumination is provided by some other source a separate
luminaire is not required for service equipment - ANSWER-true


.(true/false) it is beneficial to have a conductor with a temperature rating higher
than the terminal it is connected to because you can use the higher ampacity
when derating - ANSWER-true


.#18 fixture wire is considered to be protected by a 20 amp branch breaker if it
is not over ___ ft long - ANSWER-50


.a 20 amp branch circuit requires #12 conductors but you may tap off of the
#12's with #14's to feed a lighting outlet as long as the tap is not over ___ inches
long - ANSWER-18


.a 20 amp circuit with two or more receptacle outlets may use ___ or ___ amp
rated recptacles - ANSWER-15, 20


.a bathroom receptacle outlet must be put on a ___ ample circuit - ANSWER-20

,.a circuit breaker marked 120/240 volts means that it is only approved for _____
systems where the voltage to ground is not over _____ - ANSWER-grounded
120v


.a circuit breaker used to switch fluorescent lighting must be marked ____ of
_____ - ANSWER-SWP, HID


.a concrete encased electrode must consist of at least ___ft of ___ inches rebar,
or #___ bare copper - ANSWER-20
1/2
4


.a conductor encased within material of composition or thickness that is not
recognized by this code as insulation is called a ____ conductor - ANSWER-
covered


.a dwelling three stall garage requires at least _ receptacle outlets - ANSWER-3


.a dwelling unit must have at least one ___ amp laundry circuit - ANSWER-20


.a fastened in place appliance on a circuit with two or more outlets may not
take up more than ___% of the circuit rating - ANSWER-50


.a foyer requires a receptacle outlet if it is ___ sq ft or more. one is required on
each wall space that is____ ft or wider - ANSWER-60, 3

, .a ground ring must consist of at least __ ft of #__ bare copper and must be
buried at least __ inches deep - ANSWER-20
2
30in


.a hallway requires a receptacle outlet if it is ___ ft or longer - ANSWER-10


.a lock nut on an emt connector is not considered to be adequate bonding if you
encounter concentric knockouts and the voltage is over ___ to ground -
ANSWER-250


.a multiwire circuit must have disconnect that will disconnect all _________
conductors simultanelously - ANSWER-ungrounded


.a multiwire circuit shall be permitted to be considered as _____ circuits -
ANSWER-multiple


.a premises that has two different electrical systems in it must have the
ungrounded conductors from each system identified by ____ and ______ -
ANSWER-phase, system


.a rod or pipe electrode must consist of ___ ft of at least ___ inches pipe or ___
inches rod unless listed or other diameters - ANSWER-8
3/4
5/8

Document information

Uploaded on
April 27, 2025
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Isabellai
3.5
(6)
Sold
33
Followers
11
Items
1700
Last sold
2 weeks ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions