MOSBY CT REGISTRY REVIEW EXAM WITH HIGHEST PROBILITY 100%PASS.

Document preview thumbnail
Preview 4 out of 87 pages

voxel contains 25% air, 50% water and 25% bone. The CT number for this voxel would be expected to be _____ HU? - CorreCt Answers -0 How many pixels are contained in a 1,024 matrix image? - CorreCt Answers -D. 1,048,576 MATH 1024 X1024 It is located in a matrix and is a two dimensional representation of a voxel - CorreCt Answers -pixel When CT numbers are calculated for voxels (volume elements) of tissue what is assigned the calculated number and a subsequent shade of gray - CorreCt Answers -pixel What is defined as a picture element or the smallest component of the digital image - CorreCt Answers -pixel A CT scan produces a 512x512 matrix transverse image of a 30 cm diameter FOV. Each pixel is approximately _____ mm on a side. - CorreCt Answers -0.6 equation: 30cm/512= .058cm convert to mm and its .58 which is approximately 0.6The ability of a system to define small objects distinctly is referred to as which of the following? - CorreCt Answers -spatial resolution Which of the following terms is/are commonly used to describe a CT scanner's ability to differentiate objects with similar linear attenuation coeffiecents - CorreCt Answers -*spatial resolution *sensitivity Which of the following factors have an affect on contrast resolution - CorreCt Answers -*patient size *slice thickness *pixel size *mAs/dose As mAs/dose increases contrast resolution decreases - CorreCt Answers - FALSE

Content preview

MOSBY CT REGISTRY REVIEW EXAM WITH
HIGHEST PROBILITY 100%PASS.

A voxel contains 25% air, 50% water and 25% bone. The CT number for this
voxel would be expected to be _____ HU? - CorreCt Answers -0


How many pixels are contained in a 1,024 matrix image? - CorreCt
Answers -D. 1,048,576



MATH 1024 X1024


It is located in a matrix and is a two dimensional representation of a voxel -
CorreCt Answers -pixel



When CT numbers are calculated for voxels (volume elements) of tissue
what is assigned the calculated number and a subsequent shade of gray -
CorreCt Answers -pixel



What is defined as a picture element or the smallest component of the
digital image - CorreCt Answers -pixel


A CT scan produces a 512x512 matrix transverse image of a 30 cm diameter
FOV. Each pixel is approximately _____ mm on a side. - CorreCt Answers
-0.6 equation: 30cm/512= .058cm convert to mm and its .58 which is
approximately 0.6

,The ability of a system to define small objects distinctly is referred to as
which of the following? - CorreCt Answers -spatial resolution


Which of the following terms is/are commonly used to describe a CT
scanner's ability to differentiate objects with similar linear attenuation
coeffiecents - CorreCt Answers -*spatial resolution
*sensitivity


Which of the following factors have an affect on contrast resolution -
CorreCt Answers -*patient size

*slice thickness
*pixel size
*mAs/dose


As mAs/dose increases contrast resolution decreases - CorreCt Answers -
FALSE


As mAs/dose increases contrast resolution INCREASES - CorreCt Answers
-TRUE



The ability of a CT scanner to accurately image objects with similar
densities is termed - CorreCt Answers -*contrast resolution
*sensitivity


Which of the following has a direct relationship on increasing contrast
resolution - CorreCt Answers -*mAs/dose increase
*Slice thickness

,For a particular CT scanner's beam quality, the linear attenuation
coefficient for water is 0.20 cm-1 and for a certain tumor is 0.21 cm-1. What
is the CT number of the tumor? - CorreCt Answers -50. Equation (.21-
.20/.21) × 1000= 50


A CT scanner with poor contrast resolution or low sensitivity has difficulty
separating - CorreCt Answers -tissues whose linear attenuation coefficients
are nearly equal


What is the basic physical quantity being measured by a CT system -
CorreCt Answers -Linear attenuation coefficient



Assume the linear attenuation coefficient is 0.20 cm-1 for water and 0.40
cm-1 for tissue within a given voxel. What is the CT number in Hounsfield
units for the pixel representing this voxel? - CorreCt Answers -
+1,000....Equation { (.4-.2) /.2} x 1000


What fraction of monoenergetic x-rays will be absorbed by a 20-cm thick
material having a linear attenuation coefficient of 0.05 cm-1? - CorreCt
Answers -0.63



The contrast resolution of CT is approximately ? % - CorreCt Answers -0.3
to 0.6


This term describes the ability CT scanner to differentiate objects with
MINIMAL differences in attenuation coefficients - CorreCt Answers -
contrast resolution

, What is the term for resolution of a CT scanner referred to as the system's
ability to differentiate objects with SIMILAR densities. - CorreCt Answers -
contrast resolution


In order to pass ACR CT accreditation, the CT scanner's adult head protocol
must be within - CorreCt Answers -1.0


The QC test for the average CT number for water should be done - CorreCt
Answers -Daily



The following are all basic tenets of a QC program for computed
tomography scanner - CorreCt Answers -*QC test must be conducted
regularly
*Accurate record keeping
*all test results must be interpreted promptly


Using the ACR CT accreditation phantom, module 3 is used to measure
which of the following - CorreCt Answers -CT number uniformity


The following QC test should be done on a monthly basis - CorreCt
Answers -high contrast resolution



The CT number at the center of a uniformly filled water phantom should
ideally be - CorreCt Answers -0


The ACR CT accreditation phantom is designed to perform QC
measurements of - CorreCt Answers -*positioning accuracy and light
accuracy alignment only

Document information

Uploaded on
April 25, 2025
Number of pages
87
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$25.86

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
munenebeth20
1.0
(1)
Sold
1
Followers
0
Items
333
Last sold
6 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions