100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Standpipe system s-13 , s-14 , Question and answers correctly solved 2025

Rating
-
Sold
-
Pages
2
Grade
A+
Uploaded on
24-04-2025
Written in
2024/2025

Standpipe system s-13 , s-14 , Question and answers correctly solved 2025 Whether a building must be provided with standpipe system or not is not generally set forth in New York City building code, however the firecode contain several standpipe requirements such as for high piled combustible storage and for buildings constructed streets of substandard width - correct answer Must be inspected and maintained personally supervise(fc905.1.1) and be performed in accordance with NFPA(national fire protection Association) NFPA 25 2002 addition and NFPA 1962, 1998 edition 901.7.1 impairment coordinator the building owner Shall assign a impairment coordinator to comply with requirements of this section - correct answer In the absence of a specific designee the owner shall be considered the impairment coordinator 901.6.2 records. Records of all systems inspections tests, servicing and other maintenance required by this code - correct answer Shall be maintained on the premises for minimum of 3 years and made available for inspection by any department representative Minor defects observed by c of f holder shall be reported to the owner orange and yellow deficiencies if not corrected within 30 days - correct answer Shall e deemed to be impairment and reported in writing to the fire department (fc901.7.5) For a planned removal from service no notification to the fire department is required provided the system will be - correct answer Will be returned to service within 8 hour period For unplanned removal

Show more Read less
Institution
Standpipe System S-13 , S-14 ,
Course
Standpipe system s-13 , s-14 ,








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Standpipe system s-13 , s-14 ,
Course
Standpipe system s-13 , s-14 ,

Document information

Uploaded on
April 24, 2025
Number of pages
2
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Standpipe system s-13 , s-14 , Question
and answers correctly solved 2025
Whether a building must be provided with standpipe system or not is not
generally set forth in New York City building code, however the firecode
contain several standpipe requirements such as for high piled combustible
storage and for buildings constructed streets of substandard width - correct
answer ✔Must be inspected and maintained personally supervise(fc905.1.1)
and be performed in accordance with NFPA(national fire protection
Association) NFPA 25 2002 addition and NFPA 1962, 1998 edition


901.7.1 impairment coordinator the building owner Shall assign a impairment
coordinator to comply with requirements of this section - correct answer ✔In
the absence of a specific designee the owner shall be considered the
impairment coordinator


901.6.2 records. Records of all systems inspections tests, servicing and other
maintenance required by this code - correct answer ✔Shall be maintained on
the premises for minimum of 3 years and made available for inspection by any
department representative


Minor defects observed by c of f holder shall be reported to the owner orange
and yellow deficiencies if not corrected within 30 days - correct answer
✔Shall e deemed to be impairment and reported in writing to the fire
department (fc901.7.5)


For a planned removal from service no notification to the fire department is
required provided the system will be - correct answer ✔Will be returned to
service within 8 hour period


For unplanned removal from service the c of f holder impairment coordinator
and or other person responsible for inspecting maintaining or supervising the

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
flyhigher329 Liberty University
View profile
Follow You need to be logged in order to follow users or courses
Sold
339
Member since
2 year
Number of followers
175
Documents
16521
Last sold
2 weeks ago
STUDY GUIDES & ALL NURSING AND MORE EXAMS(RATED A+)

ARE YOU LOOKING FOR EXAMS!! MAY IT BE NURSING,EMT,REALTORS e.t.c WELCOME TO OUR SHOP FOR ALL YOU NEED TO PASS COZ WE ARE VERIFIED AND GUARANTEED TO PASS, DONT FORGET TO GIVE A REVIEW AFTER YOU HAVE PASSED THE EXAMS.........

3.8

57 reviews

5
24
4
10
3
14
2
4
1
5

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions