Questions and Answers 100% Pass
Which of the following are a type of sprinkler?
A) ESFR
B) EC
C) AF
D) A and B - ✔✔A and B
Foam water system design and installation requirements are regulated by
___________.
A. NFPA 13
B. NFPA 13R
C. NFPA 25
D. NFPA 16 - ✔✔NFPA 16
True or False, NFPA 72 allows only manual pull stations and water flow detection
devices to be used on shunt systems. Fire detection devices are not permitted. -
✔✔True
The fire alarm control panel (FACP) is essentially the _____ of the system. - ✔✔Brain
Heat sensing fire detector color coding has a RED extra high temperature rating of?
A.) 0-99f
COPYRIGHT © 2025 BY SOPHIA BENNETT, ALL RIGHTS RESERVED 1
,B.)175-249f
C.) 325-399f
D.) 500-575f - ✔✔325-399f
According to NFPA, travel distances to a manual pull station should not exceed
_____ feet.
A. 100
B. 200
C. 300
D. 400 - ✔✔200
What color tag is used to indicate that an alarm system is impaired?
A. White
B. Yellow
C. Blue
D. Red - ✔✔Red
About _____ % of fire deaths are attributed to smoke inhalation and not to burns.
A. 55%
B. 60%
C. 65%
D. 70% - ✔✔65%
When performing maintenance inspections of occupancies with alarm systems, the
first step will be to:
A) Check for green light indicating normal operation
B) Confirm monitoring status with alarm company
COPYRIGHT © 2025 BY SOPHIA BENNETT, ALL RIGHTS RESERVED 2
,C) Confirm panel is locked and inaccessible to public
D) Confirm system has been tested by licensed alarm contractor and has a current
inspection tag - ✔✔Confirm system has been tested by licensed alarm contractor and
has a current inspection tag
Most people are well aware of the dangers of fire but less aware of the dangers of
smoke inhalation. About ___% of of fire deaths are attributed to smoke inhalation
and not to burns.
A) 65
B) 80
C) 92
D) 75 - ✔✔65
If required, pull stations should be placed within ___ feet of every exit.
a) 4
b) 5
c) 10
d) does not matter what distance, as long as it is not blocked - ✔✔5
T or F: The development of clean-agent fire-extinguishing systems began in the late
1940s. - ✔✔True
NFPA 10 has assigned a maximum travel distance of __ feet from the hazard to a
Class K extinguisher?
A) 30
B) 50
C) 75
D) 100 - ✔✔30
COPYRIGHT © 2025 BY SOPHIA BENNETT, ALL RIGHTS RESERVED 3
, If an extinguisher is suitable for use on a particular class of fire, the picture-symbol
background is what color?
A.) Red
B.) Light Blue
C.) Black
D.) Grey - ✔✔Light Blue
Which one of the following is not considered a proper placement of a fire
extinguisher?
A. Visible and marked with legible signage.
B. Near Points of egress or ingress.
C. Sitting on top of a work bench with no mount.
D. Near formal paths of travel. - ✔✔Sitting on top of a work bench with no mount.
Foam extinguishes a fire by one or more of the four following methods except:
A. Smothering
B. Seperating
C. Suppressing
D. Blanketing - ✔✔Blanketing
In regards to carbon dioxide fire-extinguishing systems, total flooding systems are
designed to deliver at least ___ percent concentration of CO into and enclosed area.
A. 21
B. 19
C. 34
D. 15 - ✔✔34
What is the fuel classification for combustible metals?
COPYRIGHT © 2025 BY SOPHIA BENNETT, ALL RIGHTS RESERVED 4