Fire protection for a new construction sleeping suite not exceeding 7500 sqft - Answers
:The room must have a sprinkler system and complete smoke detection OR sprinkler
system with QRS or residential sprinklers

Fire protection for a new construction sleeping suite greater than 7500 sqft - Answers
:The room mush have direct supervision AND total coverage automatic smoke detection
and sprinkler system protection with QRS or residential sprinkler

Fire protection for a medical gas storage room with greater than 3000 cubic feet worth
of Medical Gas - Answers :Permitted in 1 hour FRR enclosure with vents

A hospital and a business occupancy can be separated by this FRR - Answers :2 hour
FRR

A ambulatory care facility and a business occupancy can be separated by this FRR -
Answers :1 hour FRR

How far can a space be in a room from a exit corridor - Answers :100 feet
(Please note that it has to be 150/200 feet from the actual exit or smoke door)

How far can a space be in a room from a exit or smoke compartment door. - Answers
:200 feet if sprinklered
150 feet if non sprinklered

What FRR does linen and waste collection rooms required in Hospitals - Answers :1
hour FRR

If a healthcare facility is above a business occupancy what do they need to be
separated by? - Answers :1 hour FRR between the healthcare and business floors

If a healthcare facility is above a mechanical equipment room what do they need to be
separated by? - Answers :2 hour FRR between the healthcare and business floors

What is the minimum ceiling height in patient areas? - Answers :7' 10"

What is the minimum ceiling height in corridors - Answers :7' 6"

What is the minimum required corridor in patient areas? - Answers :8 feet

What is the minimum required corridor in non patient areas? - Answers :44 inches or
3.6666 feet

What is the required distance from a sprinkler to an obstruction - Answers :18 inches

,A vertical exit connects 3 or less stories. What type of FRR does it need - Answers :1 hr
FRR

A vertical exit connects 4 or more stories. What type of FRR does it need - Answers :2
hr FRR and must be supported by a structure having not less than a 2 hr FRR

What are the FRR for a horizontal exit? - Answers :2 hr FRR and at least one exit can
not be horizontal

Fire protection for existing construction not exceeding 5000 sqft. - Answers :The room
must have automatic smoke detection

Fire protection for existing construction up to 10,000 sqft - Answers :Additional fire
protection - Sprinkler protection and smoke partitions.

Fire protection for a non sleeping suite up to 12,500 sqft - Answers :The facility must
have either quick response sprinklers or completed smoke detection

Fire protection for a non sleeping suite up to 15,000 sqft. - Answers :The facility must
have BOTH quick response sprinklers and complete smoke detection

Where can you store up to 300 cubic feet of medical gas (12 E Cylinders) - Answers
:They can be stored in a smoke zone without seperation.

Fire protection for a medical gas storage room with 300 cubic feet to 3000 cubic feet
worth of Medical Gas - Answers :It is permitted in a non rated room with sprinkler
protection and clearance from combustibles

What are the smoke compartment rules regarding a story used by inpatients for
sleeping or treatment - Answers :The smoke compartment must be separated into two
or more smoke compartments.

What is the maximum size for a smoke compartment - Answers :22,500 sqft

What are the smoke compartment rules regarding a story used by 50 or more patients -
Answers :The smoke compartment must be separated into two or more smoke
compartments.

What FRR and door status must a new construction hazard room have that is greater
than 100 sqft have? - Answers :1 hr FRR and door closures

What FRR and door status must a new construction hazard room have that is between
50 sqft and 99 sqft? - Answers :No FRR but must have door closures

,What FRR must an existing hazard room have that is 50 sqft or greater? - Answers :1
hour FRR barrier

What must two non sprinklered areas that are occupied be separated by - Answers :1 hr
FRR

What are the FRR rules for a soiled room? - Answers :Must have a 1 hr FRR and 3/4
hour door that is self closing

A room is currently under construction, and separated by a barrier. The side of the
construction is non sprinklered and the side of no construction is non sprinklered. What
is the FRR of the barrier - Answers :1 hr FRR

What is the maximum travel distance to a fire extinguisher for a Class A hazard -
Answers :75 feet

Fire extinguisher maintenance is required to be performed on what frequency? -
Answers :Annually

If a fire extinguisher has a classification 2A-10B-C then it can be used for what fires? -
Answers :Class A
Class B
Class C

How long can a preplanned sprinkler impairment last before a fire watch or other
alternative measure be enacted? - Answers :10 hours in a 24 hr period

If you have a cloth closet that is less than 6 sqft and located in a patient room is it
required to be sprinklered? - Answers :No, it doesn't need sprinklers

When must you have a exit signage in stairwells? - Answers :When they are serving
three or more stories

A 10 foot corridor is provided in a hospital. What are the rules for furniture in the
corridor? - Answers :1. The furniture must be fixed to the floor
2. The furniture must be located on one side of the Corridor
3. Furniture groupings must be separated by >10 feet
4. Corridors must be provided with smoke detection, or furniture spaces must be under
direct supervision.

Can you put furniture in an 8 foot corridor? - Answers :Fixed furniture is permitted if 6
feet of clearance remains.

What are the requirements for locking doors in the means of egress for patients who
pose a security threat? - Answers :You must provide remote control of locks or keys
carried by staff at all times.

, When can you have dead bolt locks in a hospital? - Answers :If the hardware already
existed and the occupant load of the room is fewer than 3 people.

How high up could a partition exist before the space separated by it is considered a
separate room? - Answers :15% of the ceiling height

Please note: Fire alarm systems must be designed as if the partitions is full height.

Can you install smoke detectors in construction areas if they are not required for
construction - Answers :No, dust could set them off or damage them making them
useless.

In turns of fire protection do we treat raised floor and suspended ceilings as separate
rooms? - Answers :Yes

At what frequency do smoke detectors get tested? - Answers :Annually

Who can perform the functional testing of fire doors and window assemblies? - Answers
:Someone who possess knowledge and understandings of the door operating
components.

When should smoke dampers be test after the construction of a hospital - Answers :1
year of installation and then every 6 years after

How many exits must an outdoor storage for positive pressure gases have? - Answers
:2 or more

At what frequency do fire rated doors get inspected and tested? - Answers :Annually

What is the max amount of alcohol based hand rub permitted outside of a storage
cabinet in a single smoke compartment - Answers :10 gallons

How much can an individual alcohol dispenser have in a room, corridor, or open area? -
Answers :.32 gallons

How far must rub alcohol be from an ignition source? - Answers :1 inch but can't be
directly over it.

What type of sedation does a Class A operating room have? - Answers :Performed with
or without oral or intramuscular sedation (Minor Surgical)

What type of sedation does a Class B operating room have? - Answers :Performed with
oral, parenteral or intravenous sedation (Minor/Major Surgical)

Written for

Institution
CERTIFIED HEALTHCARE FACILITY MANAGER
Course
CERTIFIED HEALTHCARE FACILITY MANAGER

Document information

Uploaded on
April 11, 2025
Number of pages
64
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$17.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
CHC BUNDLED EXAMS
-
13 2025
$ 36.54 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
GEEKA YALA UNIVERSITY
View profile
Follow You need to be logged in order to follow users or courses
Sold
2121
Member since
4 year
Number of followers
1446
Documents
56061
Last sold
1 day ago

3.8

360 reviews

5
179
4
61
3
48
2
17
1
55

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions