INTERNACHI ELECTRICAL MATERIAL EXAM QUESTIONS WITH CORRECT ANSWERS | GRADED A

Institution
Internachi
Course
Internachi









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Internachi
Course
Internachi

Document information

Uploaded on
April 10, 2025
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

INTERNACHI ELECTRICAL MATERIAL
EXAM



T/F: Electrical service masts can support telephone cables. - Correct Answers -False

Fused neutral circuits were common in the __________. - Correct Answers -1920s

T/F: All panel enclosures need to be bonded to ground - Correct Answers -True

A live wire is sometimes called a(n) ___________. - Correct Answers -Unground
conductor *It's unground and there is nowhere for excess electricity so it is "Live"

In a false grounded receptacle, the ground wire is connected to ______________. -
Correct Answers -The grounded conductor

A 4-wire, 240V cable assembly has _________, one neutral, and one ground conductor
- Correct Answers -Two hots

Most circuits in North America are wired with _________ cable type - Correct Answers -
Non-Metallic

NM cable should be supported every _____ feet and within _____ feet from boxes and
terminations - Correct Answers -4.5 feet, 1 feet

Size of White NM cable (according to color coding system) - Correct Answers -14 AWG

Size of Yellow NM cable (according to color coding system) - Correct Answers -12 AWG

Size of Orange NM cable (according to color coding system) - Correct Answers -10
AWG

Size of Black NM cable (according to color coding system) - Correct Answers -8 AWG
and 6 AWG

Which type of over-current protection device provides fire protection by opening the
circuit if an arcing fault is detected? - Correct Answers -GFCI

Standards of practice for smoke alarms? - Correct Answers -Home inspector is required
to report the presence/ absence of smoke alarms or CO alarms

, ______________ electrical wiring in an attic should not be within 6 feet of the entrance
opening. - Correct Answers -Unprotected

Every 5 to 6 feet (roof), rigid service masts should be secured to __________. - Correct
Answers -The Structure Points.

What clothing is unsuitable to wear during an electrical inspection - Correct Answers -
Nylon Clothing

What location in the home requires fixed lighting? - Correct Answers -Kitchen

T/F: The inspector is required to test forVoltage drop on electrical receptacles - Correct
Answers -False

Are horizontally mounted face-up countertop receptacles allowed? - Correct Answers -
No, Because water from a spill can go in.

Electric panel buses colored red, blue, and black are indicative of a ______________. -
Correct Answers -3-Phase Supply

A service entrance with ________ connected conductor(s) is a 3-phase supply. -
Correct Answers -Four

If _______ is/are present, the panel should not be opened to inspect - Correct Answers
-Arcing, Smoke, Exposed Wiring, Moisture, Rusting

______________ occurs when a spark jumps between an energized part and a
grounded part - Correct Answers -Arc-Flashing

A _____-amp breaker should supply a minimum #12 conductor. - Correct Answers -20

A __________ conductor should be connected to a 15-amp fuse or breaker. - Correct
Answers -14 AWG

Several grounded conductors ___________ terminate on the same lug. - Correct
Answers -Should not

What type of wiring do we need to recommend a specialist and why? - Correct Answers
-Aluminum: Less durable, More expansion (loose connections), Can arc and catch fire

COPALUM is the only approved repair to _________wire terminations? - Correct
Answers -Aluminum

The first kind of residential wiring is called - Correct Answers -Knob-and-tube

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
mereka Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
457
Member since
2 year
Number of followers
215
Documents
9078
Last sold
1 day ago
anchor

on this page, you will find all documents, package deal

3.9

87 reviews

5
43
4
15
3
13
2
5
1
11

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions