100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

MASSACHUSETTS OIL BURNER LICENSE NEWEST ACTUAL EXAM TEST BANK PREDICTOR 350 VERIFIED QUESTIONS AND CORRECT DETAILED ANSWERS (DETAILED RATIONALES) | GRADED A+ GUARANTEED PASS

Rating
-
Sold
-
Pages
93
Grade
A+
Uploaded on
09-04-2025
Written in
2024/2025

MASSACHUSETTS OIL BURNER LICENSE NEWEST ACTUAL EXAM TEST BANK PREDICTOR 350 VERIFIED QUESTIONS AND CORRECT DETAILED ANSWERS (DETAILED RATIONALES) | GRADED A+ GUARANTEED PASS What is the first thing a tech should do when arriving at a no combustion call? - ANS :Ask how many times the customer reset the unit. What is the best long term solution for preventing a clogged nozzle? - ANS :-Remove any underground storage tanks. -Install a quality oil filter. -Cut the suction line 10" above the tank outlet to prevent sludge. Hot water and steam valves are interchangeable. - ANS :False When in the presence of a flame, a cad cell normally reads.. - ANS :300-1000 ohms If a pump is used to bring oil to a level higher than the tank, an oil safety valve is required. - ANS :True 1 | P a g e 2 On a call where a hydronic heat system is putting out too much heat on the stack, the issue may be.. - ANS :-Too much draft. -Not enough combustion air in the equipment room. -Air leakage into chamber. A high CO2 reading is caused by.. - ANS :Incomplete combustion An often overlooked cause of a high CO2 reading is.. - ANS :Not enough combustion air in the equipment room. When multiple pumps are wired together in a heating system, they should be wired in.. - ANS :parallel In a series circuit.. - ANS :Current has one path. When 2 burners are connected to the same chimney.. - ANS :Sufficient draft must be obtained to operate both units. The ignition transformer is located.. - ANS :In the primary control. When safeties are wired in series one safety will affect the operation of the others. - ANS :True A stack switch is no longer allowed to be installed or replaced because.. - ANS :It's safety cutout time is higher than what is now required. 2 | P a g e

Show more Read less
Institution
MA OIL BURNER LICENSE
Course
MA OIL BURNER LICENSE











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
MA OIL BURNER LICENSE
Course
MA OIL BURNER LICENSE

Document information

Uploaded on
April 9, 2025
Number of pages
93
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

1




MASSACHUSETTS OIL BURNER LICENSE
NEWEST 2024-2025 ACTUAL EXAM TEST BANK
PREDICTOR 350 VERIFIED QUESTIONS AND
CORRECT DETAILED ANSWERS (DETAILED
RATIONALES) | GRADED A+ GUARANTEED
PASS

What is the first thing a tech should do when arriving at a no combustion call? - ANS :Ask how
many times the customer reset the unit.



What is the best long term solution for preventing a clogged nozzle? - ANS :-Remove any
underground storage tanks.

-Install a quality oil filter.

-Cut the suction line 10" above the tank outlet to prevent sludge.



Hot water and steam valves are interchangeable. - ANS :False



When in the presence of a flame, a cad cell normally reads.. - ANS :300-1000 ohms



If a pump is used to bring oil to a level higher than the tank, an oil safety valve is required. -
ANS :True




1|Page

, 2



On a call where a hydronic heat system is putting out too much heat on the stack, the issue
may be.. - ANS :-Too much draft.

-Not enough combustion air in the equipment room.

-Air leakage into chamber.



A high CO2 reading is caused by.. - ANS :Incomplete combustion



An often overlooked cause of a high CO2 reading is.. - ANS :Not enough combustion air in the
equipment room.



When multiple pumps are wired together in a heating system, they should be wired in.. - ANS
:parallel



In a series circuit.. - ANS :Current has one path.



When 2 burners are connected to the same chimney.. - ANS :Sufficient draft must be obtained
to operate both units.



The ignition transformer is located.. - ANS :In the primary control.



When safeties are wired in series one safety will affect the operation of the others. - ANS :True



A stack switch is no longer allowed to be installed or replaced because.. - ANS :It's safety
cutout time is higher than what is now required.




2|Page

, 3



What is a power venter and what does it do? - ANS :An electrical device that sends fluid gases
into the chimney connector.



A burner in a confined space using 1 GPH of #2 fuel oil requires what size permanent opening
for combustion air? - ANS :140"



The difference between an adjustable flame retention burner and a fixed flame retention
burner is? - ANS :Air inlets can be adjusted



Ignitor position can be adjusted



Fuel can be adjusted



Oil tank design, construction, installation and testing shall be in accordance with.. - ANS :527
CMR 9.0



Heat is a form of.. - ANS :Energy



If a burner is operational but the circulator pump isn't running.. - ANS :The pump relay is not
working correctly



A method of dealing with low viscosity/cold temps with #2 oil? - ANS :Increase pump pressure/
decrease nozzle size



What is needed at the outlet of an oil tank? - ANS :Thermal safety valve


3|Page

, 4



Where do you obtain an installation permit for oil burners? - ANS :Fire Dept



How many Btu's approximately in 1 gal of #2 fuel oil? - ANS :140,000 btu's



Solid state ignition is superior to spark because - ANS :It is not affected by reduced voltage



What is an installation? - ANS :The complete setting in place, ready for operation, of an oil
burner appliance together with its accessories and equipment.



How far must a power vent terminate from an opening or window? - ANS :4'



A pump in a one pipe system that is full of air can be self purged. - ANS :False



List the minimum size of an oil supply line. - ANS :3/8"

Oil lines that are buried in concrete should: - ANS :Be sleeved in non-metallic pipe



We install oil safety valves and oil pressure reducing valves to: - ANS :Reduce the head
pressure at the pump and prevent the tank from siphoning in the event of a suction line leak



One advantage of a two stage fuel unit on a one pipe system application is: - ANS :There are
no advantages



If the vacuum gauge reading is substantially above the calculated reading with the burner
running, the cause could be: - ANS :Restriction in supply line



4|Page

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
JoyceWWales Teachme2-tutor
View profile
Follow You need to be logged in order to follow users or courses
Sold
109
Member since
2 year
Number of followers
16
Documents
2040
Last sold
1 week ago
MitchelleWales

HI, WELCOME TO MY PAGE EXCELLENT HOMEWORK HELP AND TUTORING ,ALL KIND OF QUIZ AND EXAMS WITH GUARANTEE OF AN A+ Hi there! I'm JOYCE, I'm, a dedicated medical doctor (MD) with a passion for helping students excel in their exams. With my extensive experience in the medical field, I provide comprehensive support and effective study techniques to ensure academic success. My unique approach combines medical knowledge with practical strategies, making me an invaluable resource for students aiming for top performance. Discover my proven methods and start your journey to academic excellence with me on Stuvia today and I'm here to provide high-quality study materials to help you succeed. With a focus on clarity and usefulness, my notes are designed to make your studying easier and more efficient. If you ever need assistance or have any questions, feel free to reach out.

Read more Read less
3.9

25 reviews

5
14
4
1
3
6
2
1
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions