WITH CORRECT VERIFIED
ANSWERS A+ GRADED
ck
lo
yc
ud
St
, ______ should not be disassembled in the field
Oil buffers
Two safety precautions to be followed when first entering the elevator pit are to have the
________ open and the pit light on
pit stop switch
Tension on the governor rope is maintained by using a _________________.
tension sheave
ck
The ASME Safety Code requires oil buffers for elevators when traveling at a car speed of
___________.
over 200 fpm
lo
If the pit extends more than _______ below the sill of the access door, both a fixed vertical
ladder and a light switch shall be located within reach of the access door
35"
yc
the purpose of the ____ is to reduce the shearing action of the edge of the sill or threshold
sill guard
ud
the elevator pit is located between the sill level of the lowest landing and the ____
the floor of the elevator hoistway
when working in a pit that has been waterproofed, ________
you must notify the general contractor before drilling or cutting into the wall or pit floor
St
If the compensating sheave diameter is smaller than the distance between the car and
counterweight compensating rope hitches, the plumb lead of the compensating rope from the
compensating sheave should be from the _______ side.
counterweight
The location of the governor tension sheave is determined ___________.
from the final layout