Establishing notification zones within premises shall ____________________. - be consistent with the building evacuation plan. In a common talk system if the control equipment does not indicate the location of the telephone station or telephone jack shall be clearly and permanently labeled to ________________________. - Identify his or her location to the control center by voice. The maximum number of water-flow switches that can be connected to a initiating device circuit is ____. - 5 The maximum allowable response delay on an alarm signal from an initiating device shall receipt by the control unit shall be _________. - 10 Seconds A lobby smoke detector shall be located in the ceiling within ___________ of the centerline of each elevator door within the elevator bank under control of the detector. - 21 feet

Content preview

FSDNY S98 MAIN EXAMINATION TEST 2025/2026
QUESTIONS WITH ANSWERS GRADED A+
✔✔Establishing notification zones within premises shall ____________________. -
✔✔be consistent with the building evacuation plan.

✔✔In a common talk system if the control equipment does not indicate the location of
the telephone station or telephone jack shall be clearly and permanently labeled to
________________________. - ✔✔Identify his or her location to the control center by
voice.

✔✔The maximum number of water-flow switches that can be connected to a initiating
device circuit is ____. - ✔✔5

✔✔The maximum allowable response delay on an alarm signal from an initiating device
shall receipt by the control unit shall be _________. - ✔✔10 Seconds

✔✔A lobby smoke detector shall be located in the ceiling within ___________ of the
centerline of each elevator door within the elevator bank under control of the detector. -
✔✔21 feet

✔✔Alarm verification time cannot delay the alarm longer than ____________ if a smoke
detector is programmed for alarm verification. - ✔✔60 seconds

✔✔Visual notification appliances on a fire alarm system shall not be located more than
__________ from the end of the corridor. - ✔✔15 feet

✔✔The minimum audible level that is required for a sleeping area is _____ and must be
measured at the ______. - ✔✔75db; pillow

✔✔The total sound pressure level produced by combining the ambient sound pressure
level with all audible notification appliances operating in the occupied area shall not
exceed ______. - ✔✔110db

✔✔The minimum required light output for a single wall mounted visible notification
appliance on a 50ft by 50ft room is ________. - ✔✔94CD

✔✔In 40 feet by 40 feet room with 10 feet high ceiling ________ is the number of 15cd
strobe lights installed. - ✔✔4

✔✔An office space has an ambient sound level of 60dba, the minimum sound level
required to ensure that alarm signals are clearly heard should be ______. - ✔✔75dba

, ✔✔The average ambient sound level for business occupancies is _______. - ✔✔60dba

✔✔When connecting visual notification appliances to the fire alarm system, the flashes
shall not exceed ______________. - ✔✔two flashes per second

✔✔When connecting visual notification appliances on a fire alarm system, the flash rate
shall not exceed ____________. - ✔✔two flashes per second

✔✔______ is the number of speakers required for each notification zone. - ✔✔two

✔✔A speaker is tapped at 1/4 watt and produces a sound level of 75db, if the speaker
is tapped the 1 watt will produce _____. - ✔✔81db

✔✔A DACT shall be configured to seize the phone lines by __________________. -
✔✔disconnecting the outgoing and incoming calls by off hook

✔✔If either transmission channel for a DACT fails a trouble signal shall be sent within
________________. - ✔✔240 seconds / 4 minutes

✔✔If either transmission channel for a DACT fails, a trouble signals shall be sent within
____________. - ✔✔240 seconds / 4 Minutes

✔✔A failure of a dact to transmit an alarm shall not prevent subsequent attempts,
__________________________. - ✔✔up to a minimum of 5 and a maximum of 10 have
been attempted

✔✔In the event of loss of primary lighting for a proprietary supervising station the
emergency light shall operate for not less than ________. - ✔✔26 Hours

✔✔Upon recite of trouble signal pertaining solely to matters of equipment maintenance
of the fire alarm system, the proprietary supervising station operator shall initiate action
to perform the following:
______________________________________________________________. -
✔✔Dispatch personnel to arrive within four (4) hours to initiate maintenance if
necessary. Notify the AHJ when interruption of service exists for four (8) hours or more.

✔✔The central station shall dispatch personnel to arrive within ______ if protected
premises equipment needs to be manually reset after testing. - ✔✔2 hours

✔✔Low power radio transmitters shall automatically repeat alarm transmission at
intervals not exceeding __________ until the initiating device is returned to its non-
alarm condition. - ✔✔60 seconds

Document information

Uploaded on
April 4, 2025
Number of pages
10
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMCAFE
3.3
(18)
Sold
152
Followers
7
Items
26057
Last sold
2 days ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions