ELETRICIAN NCCER Which article of the NEC covers grounding? - Answer- Article 250 What is a dropout plate? - Answer- Metal plate with a curve surface for cable to follow as it passes from the tray All of the following are common service voltages in the United States Except: - Answer- 372/575 3-Phase, 4-wire What does a GFCI breaker do? - Answer- Opens a circuit to prevent operation of an electrical device What will happen when one or more coils in a winding are grounded? - Answer- The motor will automatically blow fuses eight incandescent lighting fixtures are to be installed. Each fixture is 120 volts, with a 200-whatt lamp what is the total connected load? - Answer- 13.3 Amps The __________must be grounded in a bussed glutter if use as the main service equipmemt - Answer- Neutral busbar When wall mounting cable tray, ensure that - Answer- The building structure is strong enough to support the tray system The purpose of sealing cable ends when reels of cable are in storage is ______________ - Answer- The outer covering on liquid-tight flexible metal conduit is use for - Answer- A moisture seal A good electrical connection should - Answer- Be mechanically and electrically secure The symbol normally use for duplex - Answer- Circle with two parallel lines draw through it Disconnecting means are covered in - Answer- NEC section 110-22 In relation to switches, the term throw refers to the - Answer- Number of internal operations that switch can perform A 3-phase, 4-wire, 480v service requires ________ current transformers - Answer- 3 Services conductors and equipment are covered in - Answer- NEC Article 230 The NEC required that all receptacles installed on 25 amp and 20 amp branch circuits be__________ receptacles - Answer- Grounding The circular mil is based on the - Answer- Cross-sectional area of the wire

Show more Read less
Institution
ELETRICIAN NCCER
Course
ELETRICIAN NCCER










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ELETRICIAN NCCER
Course
ELETRICIAN NCCER

Document information

Uploaded on
April 3, 2025
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ELETRICIAN NCCER
Which article of the NEC covers grounding? - Answer- Article 250

What is a dropout plate? - Answer- Metal plate with a curve surface for cable to follow as it passes
from the tray

All of the following are common service voltages in the United States Except: - Answer- 372/575 3-
Phase, 4-wire

What does a GFCI breaker do? - Answer- Opens a circuit to prevent operation of an electrical
device

What will happen when one or more coils in a winding are grounded? - Answer- The motor will
automatically blow fuses

eight incandescent lighting fixtures are to be installed. Each fixture is 120 volts, with a 200-whatt
lamp what is the total connected load? - Answer- 13.3 Amps

The __________must be grounded in a bussed glutter if use as the main service equipmemt -
Answer- Neutral busbar

When wall mounting cable tray, ensure that - Answer- The building structure is strong enough to
support the tray system

The purpose of sealing cable ends when reels of cable are in storage is ______________ -
Answer- to keep moisture from creeping in

The outer covering on liquid-tight flexible metal conduit is use for - Answer- A moisture seal

A good electrical connection should - Answer- Be mechanically and electrically secure

The symbol normally use for duplex - Answer- Circle with two parallel lines draw through it

Disconnecting means are covered in - Answer- NEC section 110-22

In relation to switches, the term throw refers to the - Answer- Number of internal operations that
switch can perform

A 3-phase, 4-wire, 480v service requires ________ current transformers - Answer- 3

Services conductors and equipment are covered in - Answer- NEC Article 230

The NEC required that all receptacles installed on 25 amp and 20 amp branch circuits
be__________ receptacles - Answer- Grounding

The circular mil is based on the - Answer- Cross-sectional area of the wire

,A transformer with the primary of 400 turns and a secondary of 300 turns has a - Answer- Step
down turns ratio of 4:3

Of the termination classes listed below,_____ is the only one that provides a seal against external
elements - Answer- Class 1

Unless otherwise noted, the calculations in AC circuits ______ values - Answer- Rms

When the coil turns increased the ________ - Answer- Induced voltage is increased

As the temperature surrounding a self regulating heating cable rises, the ________ - Answer-
Resistance of the polymeric core increases

The motor type that has the highest starting torque is the _________ motor - Answer- Capacitor -
start

For a given number of poles, the________ determines the speed of an AC Motor. - Answer-
Frequency

Both induction and synchronous motor operate on the principle of the rotating________field -
Answer- Magnetic

A Transformer has 200 turns in the primary, 150 turns in the secondary, and 120VAC applied to
the primary. The voltage across the secondary is - Answer- 90 Volts

The output capacity of a motor is rated in - Answer- Horsepower

The synchronous speed at witcha 4 pole, 60 Hz induction motor operates is ________ rpm -
Answer- 1800

The sine of 0 degree is - Answer- 0

In a AC circuit containing resistance only, _______ 12A will flow if the resistance is 10 ohms and
the voltage is 120V - Answer- 12A

The _____ rotor types are generally rugged - Answer- Squirrel cage

The componente labeled 7 in figure 1 is a (an) - Answer- End seal

Meters used in AC circuits indicate the_______ - Answer- Effective

Proofs tests are made at________ oF the original factory voltage - Answer- 60%

Which type of heating cable can not be cut and terminated in the field? - Answer- Mineral insulated

The secondary of a CT under load should not be opened because of______ - Answer- Induced
hight voltage

In a transformer,______ - Answer- Electromagnetic induction occurs

, When a ground rod is installed, the top of the rod must be positioned _____.grade - Answer- Flush
with or below

When making offset bends, the two kicks must be made perfectly parallel or the resulting offset will
have a ________ - Answer- Crooked bend

All of the following types of condulet may be used as a pulling point for conduit that requires a 90
degree change in direction, except_______ - Answer- C

To be effective, a grounding system must limit the voltage on the electrical system and protect it
from all of the following, except ______ - Answer- Undervoltage conditions

What is the most common service use in a temporary power panel? - Answer- 120/240 volt, 1-
phase, 3-wire

What are the 2 most common types of overcurrent protective devices? - Answer- Circuit breakers
and fuses

What instrument is use to perform an insulation resistance test on a 480 volt motor winding? -
Answer- Megohmmeter

What is a seal installed in a run of conduit in a class I location? - Answer- Prevent the passage of
explosive gases in the conduit

Which of the following is the correct formula for OHM's law? - Answer- I=E/R

Which of the following testing instruments operated on the current transformer principle - Answer-
Clamp-on ammeter

A drowning showing a point A to point B hookup of conductors is called a - Answer- Wiring
diagram

What does HOA usually mean in a motor control circuit - Answer- Hands of automatic

A120/208 Volt feeder consist of an 800 ft run of 500 kcmil aluminum wire in conduit. This feeder
has 5% voltage drop. What will the phase-toPhase voltage be at the load end - Answer- 197.60
volts

What is voltage? - Answer- electromotive force

What is the standard wire size system used in the United States? - Answer- AWG

A switch labeled "AL-CU" can be use with what type of wire? - Answer- Aluminum Copper and
copper clad aluminum

What type of conduit fitting is usually placed in the middle of a long run of rigid metal conduit to
provide access for pulling wire - Answer- C

What is the largest size of aluminum rigid conduit couplings? - Answer- 6"

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Freshy Oxford University
View profile
Follow You need to be logged in order to follow users or courses
Sold
51
Member since
1 year
Number of followers
4
Documents
6784
Last sold
6 days ago

3.6

10 reviews

5
3
4
4
3
1
2
0
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions