p p p p p
cation Exam Study Guide p p p
Terms in this set (278) p p p p
Original
UDC was required at time of installation for all systems installed after?
p p p p p p p p p p p
January 1, 2000 p p
July 1, 2005, service techs shall possess or work under someone who has acurrent
p p p p p p p p p p p p p p p
certification indicating he or she has passed the? p p p p p p p
ICC UST Service Technician Exam
p p p p
ICC cert must be renewed every?
p p p p p
24 months
p
Service techs must possess or be employed by a person who has theappropriate
p p p p p p p p p p p p p p
contractor's license unless? p p
The individual has a tank testing license
p p p p p p
Service tech is defined by any individual who?
p p p p p p p
Tests UST monitoring equipment, trouble shoots UST systems, and/orinstalls
p p p p p p p p p
UST monitoring equipment.
p p p
If the manufacturer training no longer exist, the local agency may?
p p p p p p p p p p
Approve comparable alternate training . p p p p
UST includes? p
Tank and connected piping
p p p
,What is considered a UST?
p p p p
A petroleum storage tank.
p p p
What UST system meets the requirements for secondary containment?
p p p p p p p p
Doubled wall tanks p p
According to title 23; the following piping components if installed after July 1,1987
p p p p p p p p p p p p p p
must have secondary containment.
p p p
Pressured product piping p p
Considered "pipe" on tanks installed after July 1, 2003. Press
p p p p p p p p p
ured product piping and below ground vapor recovery.
p p p p p p p
Under dispenser containment (UDC) was required for all existing USTsystem
p p p p p p p p p p
s by
p
December 31, 2003 p p
System for exchanging gas vapors in a storage tank and product in a fueldelivery t
p p p p p p p p p p p p p p p
ruck
Stage 1 vapor recovery
p p p
An approved method for non-
p p p p
visual monitoring for existing UST systems.Statistical Inventory Reconciliation (SI
p p p p p p p p p
R)
ATG must be capable for detecting a release of?
p p p p p p p p
0.2 gallons per hour
p p p
,What is no longer an approved method for non-
p p p p p p p p
visual monitoring on existing USTsystems?
p p p p p
Manual inventory reconciliation.
p p
Automatic line leak detectors installed on underground piping with secondarycontai
p p p p p p p p p p
nment shall be capable of detecting a leak of ?
p p p p p p p p p
3 gallons per hour at 10 psi
p p p p p p
How often should ATG be programmed to test the tank?
p p p p p p p p p
At least monthly
p p
According to PEI RP 300, a combustible gas can be used to?
p p p p p p p p p p p
Detect vapor leaks in a vapor recovery system.
p p p p p p p
According to PEI RP 300, a written scope of work for vapor recovery installationshou
p p p p p p p p p p p p p p
ld include?
p
Construction plans p
Positive shut off overfill protection device must stop the flow of fuel when the tankis
p p p p p p p p p p p p p p p p
no more then?
p p
95% full p
According to Executive Order (EO) VR 201-
p p p p p p
A , what could cause a nozzle shutoff mechanism or malfunction?
p p p p p p p p p p p
Depended filter seal damage p p p
According to VR 201-A, breakaway reconnection must be?
p p p p p p p
Logged in GDF log p p p
, According to PEI RP 300 what is an INCORRECT method of documenting pipingloc
p p p p p p p p p p p p p
ation?
Sketching a diagram on the inside cover of vapor recovery equipmentmanual
p p p p p p p p p p p
According to PEI RP 300 as built drawing or pictures of the underground pippinga
p p p p p p p p p p p p p p
nd other components shall be
p p . p p
maintained as long as UST is in service.
p p p p p p p
According to EO VR 101-E maintenance records are required to include what?
p p p p p p p p p p p
Name and Designated UST Operator.
p p p p
The Phil-
p
Tite EVR Phase 1 system require that vapor vent pipes at any USTsystem be
p p p p p p p p p p p p p p
Used with no more than 3 p/v valves
p p p p p p p
According to EO VR 2010 after installing a new spout assembly in the Healy 900noz
p p p p p p p p p p p p p p p
zle the following test must be conducted?
p p p p p p
Nozzle dispensing shut off test
p p p p
According to Healy EO VR 201-A a vapor recovery record is to be maintainedby?
p p p p p p p p p p p p p p
Gasoline dispensing facility operator(GDF)
p p p
An enhanced leak detection test is required within how many feet of a publicdrinking
p p p p p p p p p p p p p p p
well?
1000 feet p
What are the components of the Fire Triangle?
p p p p p p p