RCO Final
RCO NEWEST ACTUAL FINAL EXAM COMPLETE QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY
GRADED A+||BRAND NEW VERSION COMPLETE EXAM FOR
STUDY
Terms in this set (107)
the vigilance feature on the 50 seconds
OCU will begin to sound an
alarm after how many
seconds of inactivity?
how many seconds does 10 seconds
the RCO have to respond
to the vigilance alarm?
what brake application will a full service
occur when the vigilance
feature is allowed to time
out?
when setup for two OCU both
operation, the locomotive
will accept an emergency
stop command from which
OCU?
what will occur when the a communication loss and full service brake application
RCL is out of range of the
OCU?
what must be done to allow press the vigilance button
the locomotive to respond
when moving the speed
selector from the stop
position?
1/1
2
, 3/16/25, 4:45 PM RCO Final
what test must be performed the full test
when linking up an RCL?
what test must a crew a crew change test (attachment test)
member perform when
changing crews and the
locomotive remains
linked?
when will the strobe lights when the remote/ manual switch is placed in remote
on the locomotive begin
to flash?
what would happen if the a low brake application with a message in the status display
primary RCO bumped the screen
direction selector into the
opposite direction while
moving?
1. apply the handbrake
2. move the engine control switch to the START/STOP/ ISOLATE
position
what are the steps to
secure a locomotive for 3. perform a securement check
short term?
4. make a 20 psi brake pipe reduction
5. turn
off the remote control transmitter
when does the OCU first 60 minites
notify the
operator that the battery is
running low?
what feature is used to check the SI/TOR switch
the amount of time
remaining on the battery?
when is the only time the when the speed selector is in the stop position
vigilance feature is
inactive?
what setting should the OCU brakes in release
speed
selector and brakes be speed selector in stop
2/1
2