MOCK Examination Clinical Anaesthesia
clinical medicine (Levy Mwanawasa Medical University)
Scan to open on Studocu
Studocu is not sponsored or endorsed by any college or university
Downloaded by Morris Muthii ()
, lOMoARcPSD|40307388
LMMU
CLINICAL ANAESTHESIA
4TH YEARS
MOCK EXAMINATION
DATE: 31st October, 2023
INSTRUCTIONS: There are three sections in this question paper with 20 number of pages.
Answer all questions in each section.
Duration of exam is 2hours 30min
SECTION A
ANSWER TRUE (T) OR FALSE (F)
1. The expression that for a given fixed mass of gas at constant temperature, the
product of pressure and volume is constant is known as…
(a) Grahams law
(b) Bernoulis principle
(c) Boyles law
(d) Daltons law
(e) Charles law
2. Applications of the Doppler shift in the measurement of blood flow involve changes
in…
(a) electrical conductivity of a moving stream of blood
(b) temperature of blood as it moves peripherally
(c) frequency response of the arterial wall
(d) frequency of reflected ultrasound waves
(e) harmonic waves of reflected arterial pulses
3. Viscosity...
(a) of a liquid rises as its temperature rises
(b) decreases as the temperature of a gas increases
1
Downloaded by Morris Muthii ()
, lOMoARcPSD|40307388
(c) is dependent on Van der Waal’s forces
(d) is dependent on molecular cohesiveness
(e) is measured in pascal/second
4. In the oscilloscope…
(a) a hot cathode is used to produce an electron beam, which passes through two
deflecting devices
(b) the saw-tooth potential deflects the beam in the X direction
(c) for an ECG a 1-mV calibration signal gives 1 cm vertical displacement of the trace
(d) there is a digital record with the simple oscilloscope
(e) there is a phosphorus screen
5. Regarding oxygen failure warning alarms…
(a) when activated the auditory alarm shall last 2 s
(b) the energy required to operate the alarm shall be derived solely from the oxygen
supply pressure
(c) the alarm shall be activated when the oxygen supply pressure starts to fall
(d) when activated the flow of nitrous oxide shall be shut off
(e) is flow dependent
6. Gases or vapours whose infrared absorption bands overlap those used in the
detection of carbon dioxide include…
(a) oxygen
(b) water vapour
(c) helium
(d) halothane
(e) nitrous oxide
7. Concerning a vaporiser for use inside a circle system….
(a) it must be temperature compensated
(b) it is best situated on the inspiratory limb
(c) its interval volume must be greater than the patient’s tidal volume
(d) accurate calibration is not essential
(e) it is generally unsuitable for administration of halothane
8. The following are true of the ideal intravascular pressure measurement device.
(a) the resonance frequency is less than 40 Hz
2