Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is achieved by the use of the- a. profile analyzer b. shadow graph c. keratometer d. burton light - ACCURATE ANSWERS a. profile analyzer Contact lens power should be specified in- a. back vertex power b. sphero-cylinder power c. power in situ d. posterier apical radius - ACCURATE ANSWERS a. back vertex power The slit-lamp illumination that gives an overall view of the cornea but limits detail is- a. sclerotic scatter b. diffuse c. specular reflection d. oscilatory - ACCURATE ANSWERS b. diffuse When a keratometric miers reflected off a soft contact lens are only clear when the wearer blinks, the lens fit is too- a. small b. large c. steep d. flat - ACCURATE ANSWERS c. steep Transient keratometric mier distortion is usually due to-

Show more Read less
Institution
NCLE
Course
NCLE











Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NCLE
Course
NCLE

Document information

Uploaded on
March 4, 2025
Number of pages
34
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

NCLE TEST QUESTIONS EXAM
2025 |GUARANTEED ACCURATE
ANSWERS |VERIFIED

Assessment of the quality of the peripheral curves (blends of a rigid
contact lens) is achieved by the use of the-
a. profile analyzer
b. shadow graph
c. keratometer
d. burton light - ACCURATE ANSWERS✔✔ a. profile analyzer


Contact lens power should be specified in-
a. back vertex power
b. sphero-cylinder power
c. power in situ
d. posterier apical radius - ACCURATE ANSWERS✔✔ a. back vertex
power


The slit-lamp illumination that gives an overall view of the cornea but
limits detail is-
a. sclerotic scatter
b. diffuse

,c. specular reflection
d. oscilatory - ACCURATE ANSWERS✔✔ b. diffuse


When a keratometric miers reflected off a soft contact lens are only clear
when the wearer blinks, the lens fit is too-
a. small
b. large
c. steep
d. flat - ACCURATE ANSWERS✔✔ c. steep


Transient keratometric mier distortion is usually due to-
a. pre-ocular tear film abnormalities
b. prolonged rigid lens wear
c. prolonged soft lens wear
d. irregular corneal astigmatism - ACCURATE ANSWERS✔✔ a. pre-
ocular tear film abnormalities


Epithelial edema which manifests itself clinically as central corneal
haze, is verified by the slit lamp using sclerotic scatter illumination.
What specific technique does the examiner use to see this condition?
a. the naked eye and an angle between the slit lamp beam and the eye of
90˚
b. the blue cobalt filter of the slit lamp and an angle of about 45˚

,c. the green filter of the slit lamp with high magnification
d. high magnification and an angle between the beam and scope of 180˚
- ACCURATE ANSWERS✔✔ a. the naked eye and an angle between
the slit lamp beam and the eye of 90˚


With a rigid contact lens in place a flourescein pattern shows a narrow
bend horizontally wih a concentration of flourescein inferiorly and
superiorly under the lens. Which one of the following type of
astigmatism is represented by this pattern?
a. lenticular astigmatism
b. residual astigmatism
c. against the rule astigmatism
d. with the rule astigmatism - ACCURATE ANSWERS✔✔ d. with the
rule astigmatism


Refractive Rx -3.00 -1.00 x 170
K's 42.00 @ 170/43.00 @ 80
Given the above Rx and K's he following diagnostic toric soft lens was
used:
B.C. 8.8
Power -3.00 -1.00 x 180
During dianostic evalutation, the above lens rotated 10 clockwise. The
lens ordered should have an axis of:
a. 10

, b. 180
c. 170
d. 160 - ACCURATE ANSWERS✔✔ b. 180


Given the same circumstances from the above question, once the
correctly ordered lens has been dispensed, the rotational marks should
settle at _______.
a. 6 o clock
b. 10 clockwise rotation
c. 10 counter clockwise rotation
d. none of the above - ACCURATE ANSWERS✔✔ b. 10 clockwise
rotation


An instrument that allows simultaneous verification of lens diameter,
optic zone width, and peripheral curve width is:
a. measuring magnifier
b. ophthalmometer
c. profile analyzer
d. radiuscope - ACCURATE ANSWERS✔✔ a. measuring magnifier
(the book says d. radiuscope)


The instrument used for magnification of the edge of a rigid CL is a
_______.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EXAMLINKS West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
57
Member since
1 year
Number of followers
6
Documents
3397
Last sold
4 days ago
ECONOMICS|NURSING|BIOLOGY |BUSINESS |LAW EXAMS |STUDY NOTESLATEST AND UPDATED .

On this page, you find all documents, package deals, and flashcards offered by seller EXAMLINKS.

3.1

17 reviews

5
4
4
4
3
3
2
2
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions