ESCO Exam Questions and Answers 100% Pass When recovering refrigerant from a medium-pressure system with more than 200 lbs. of refrigerant, recover to a level of; - 15" Hg Refrigerant should be recovered from the condenser outlet if the condenser is; - Below the receiver A new split system should be checked for leaks by; - pressurizing the system with a few ounces of system refrigerant and an inert gas. Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or greater when the annualized leak rate reaches _____ or more. - 30% Refrigerants CFC-12, HCFC-22, and HFC-134a are all classified as Type _______ substances. - A1 A high-pressure appliance containing less than 200 lbs. of an HCFC or HFC refrigerant must be evacuated (recovered) to a level of; - 0 inches of vacuum 2100% Pass Guarantee Emilly Charlotte, All Rights Reserved © 2025 When using a recovery unit on a system containing 100 lbs. of R-410A it must be evacuated to; - 0 inches of Mercury A refrigerant sensor which will sound an alarm and automatically start a ventilation system in occupied equipment rooms falls under ASHRAE Standard; - 15 When an appliance containing 50 pounds or more of a regulated refrigerant leaks refrigerant at an annual rate of 125% or more, what must be included on the leak inspections records? - Initial verification, verification tests and records of recovered refrigerant from equipment. Unless plans are made to replace a system with a leak rate that exceeds the maximum leak rate, repairs must be made within; - 30 days If a leaking appliance with a regulated refrigerant is not going to b

Show more Read less
Institution
ESCO
Course
ESCO









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ESCO
Course
ESCO

Document information

Uploaded on
March 2, 2025
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ESCO Exam Questions and Answers
100% Pass


When recovering refrigerant from a medium-pressure system with more than 200 lbs.

of refrigerant, recover to a level of; - ✔✔15" Hg


Refrigerant should be recovered from the condenser outlet if the condenser is; -

✔✔Below the receiver


A new split system should be checked for leaks by; - ✔✔pressurizing the system with a

few ounces of system refrigerant and an inert gas.


Leaks must be repaired on industrial process and refrigeration units with a 50-pound

charge or greater when the annualized leak rate reaches _____ or more. - ✔✔30%


Refrigerants CFC-12, HCFC-22, and HFC-134a are all classified as Type _______

substances. - ✔✔A1


A high-pressure appliance containing less than 200 lbs. of an HCFC or HFC refrigerant

must be evacuated (recovered) to a level of; - ✔✔0 inches of vacuum




100% Pass Guarantee Emilly Charlotte, All Rights Reserved © 2025 1

, When using a recovery unit on a system containing 100 lbs. of R-410A it must be

evacuated to; - ✔✔0 inches of Mercury


A refrigerant sensor which will sound an alarm and automatically start a ventilation

system in occupied equipment rooms falls under ASHRAE Standard; - ✔✔15


When an appliance containing 50 pounds or more of a regulated refrigerant leaks

refrigerant at an annual rate of 125% or more, what must be included on the leak

inspections records? - ✔✔Initial verification, verification tests and records of recovered

refrigerant from equipment.


Unless plans are made to replace a system with a leak rate that exceeds the maximum

leak rate, repairs must be made within; - ✔✔30 days


If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be;

- ✔✔retrofitted or retired within 12 months.


A high-pressure appliance containing less than 200 lbs. of an HCFC or HFC refrigerant

must be evacuated (recovered) to a level of; - ✔✔0 inches of vacuum


A high-pressure appliance containing 210 lbs. of R-407C refrigerant must be evacuated

(recovered) to a level of; - ✔✔10 inches of vacuum


Which of the following refrigerants is classified as a very high-pressure refrigerant? -

✔✔R-744




100% Pass Guarantee Emilly Charlotte, All Rights Reserved © 2025 2

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EmillyCharlotte Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
94
Member since
1 year
Number of followers
4
Documents
11951
Last sold
4 days ago
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.6

20 reviews

5
7
4
6
3
2
2
2
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions