100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Gas Heat esco exam Questions and Answers 100% Pass

Rating
-
Sold
-
Pages
12
Grade
A+
Uploaded on
02-03-2025
Written in
2024/2025

Gas Heat esco exam Questions and Answers 100% Pass A gas furnace to be installed in a garage. The national standards requires that the burners and ignition must be located ____ above the floor: - 18 inches A good description of how a bi-metal fan switch operates the blower motor on a gas furnace is: - Temperature on/ Temperature off Redundant gas valves used on gas furnaces will shut down if gas pressure exceeds: - 13.5 in W.C. (or 1/2 psi) This is the maximum pressure for gas valve operation Burning one cubic foot of Liquefied Petroleum gas completely will produce approximately ____ BTUs. - 2,000 - 2,500 LP gas has a specific gravity of ...? - 1.5 - 2.0 ( actual is 1.5 heavier than air which is 1.0) What is the purpose of a spoiler screw located on a burner, or adjustable-shutters? - to mix primary air and gas 2100% Pass Guarantee Emilly Charlotte, All Rights Reserved © 2025 Furnace limit switches are wired in series with the: - Gas valve A technician is using an extension ladder to work on roof top unit. The top of the ladder should extend _____ beyond the support point. - 3 feet A technician determines that a natural gas furnace has a defective heat exchanger. The technician should: - Inform the home owner and turn the gas off. A natural gas furnace usually requires _____ gas pressure AT the manifold and burners. What should the inlet pressure be to the manifold? - 3.5 in WC inlet- 5-7 in WC The vent system for a condensing furnace is classified as ___ by the National Field Gas Code. - Category IV (4) Type B vent pipe must be kept at least ____ from combustible materi

Show more Read less
Institution
ESCO
Course
ESCO









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ESCO
Course
ESCO

Document information

Uploaded on
March 2, 2025
Number of pages
12
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Gas Heat esco exam Questions and
Answers 100% Pass


A gas furnace to be installed in a garage. The national standards requires that the

burners and ignition must be located ____ above the floor: - ✔✔18 inches


A good description of how a bi-metal fan switch operates the blower motor on a gas

furnace is: - ✔✔Temperature on/ Temperature off


Redundant gas valves used on gas furnaces will shut down if gas pressure exceeds: -

✔✔13.5 in W.C. (or 1/2 psi)


This is the maximum pressure for gas valve operation


Burning one cubic foot of Liquefied Petroleum gas completely will produce

approximately ____ BTUs. - ✔✔2,000 - 2,500


LP gas has a specific gravity of ...? - ✔✔1.5 - 2.0 ( actual is 1.5 heavier than air which is

1.0)


What is the purpose of a spoiler screw located on a burner, or adjustable-shutters? -

✔✔to mix primary air and gas



100% Pass Guarantee Emilly Charlotte, All Rights Reserved © 2025 1

, Furnace limit switches are wired in series with the: - ✔✔Gas valve


A technician is using an extension ladder to work on roof top unit. The top of the ladder

should extend _____ beyond the support point. - ✔✔3 feet


A technician determines that a natural gas furnace has a defective heat exchanger. The

technician should: - ✔✔Inform the home owner and turn the gas off.


A natural gas furnace usually requires _____ gas pressure AT the manifold and burners.


What should the inlet pressure be to the manifold? - ✔✔3.5 in WC


inlet- 5-7 in WC


The vent system for a condensing furnace is classified as ___ by the National Field Gas

Code. - ✔✔Category IV (4)


Type B vent pipe must be kept at least ____ from combustible materials. - ✔✔one inch


Typical condensing furnaces have an AFUE rating of at least: - ✔✔90%


You have installed a Category IV two-pipe vent system that terminates through the roof

of the residence. The elbow for the combustion air intake, above the roof, should...? -

✔✔Point down


The reason heating thermostats have anticipators is to: - ✔✔reduce overshoot


The typical fluw gas temperature of a Category III furnace is: - ✔✔280 F - 300 F




100% Pass Guarantee Emilly Charlotte, All Rights Reserved © 2025 2

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EmillyCharlotte Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
94
Member since
1 year
Number of followers
4
Documents
11951
Last sold
4 days ago
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.6

20 reviews

5
7
4
6
3
2
2
2
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions