If an appliance cannot be converted to another fuel ex. propane to natural gas, it must be a ___ appliance - ANSWER"Dedicated" Appliance The "10ft-2ft-3ft" rule is a reference to what? - ANSWERIt means that chimneys must be 3ft above the highest point of where it passes through, while still being 2ft higher than any portion of roof within 10ft How many feet must a type B or L vent terminate, at minimum, above the highest connected appliance draft hood or flue collar? - ANSWER5 feet A gas vent (B or L) must terminate atleast ___ft above a forced air inlet located within ___ft - ANSWERA gas vent (B or L) must terminate at least 3ft above a forced air inlet located within 10ft Two ways CSST or copper tubing can be installed inside hollow walls or partitions if it is concealed? - ANSWER1) Installed in single runs that are not rigidly secured 2) With steel striker barrier, minimum 16 gauge*, barrier extends 4" *1.3mm or .0508" thick What is the minimum pressure for a pressure test? - ANSWER1 1/2 times max working pressure, never less than 3 psi What is the minimum duration for a pressure test? - ANSWER10 minutes What is the chemical formula of propane? - ANSWERC3H8 What is the specific gravity of liquid propane? - ANSWER.504 What is the specific gravity of vapor propane? - ANSWER1.50 What is the boiling point of propane? - ANSWER-44 F

Show more Read less
Institution
PROPANE AND NATURAL GAS
Course
PROPANE AND NATURAL GAS

Content preview

PROPANE AND NATURAL GAS EXAM
QUESTIONS & ANSWERS(RATED A+)
If an appliance cannot be converted to another fuel ex. propane to natural gas, it
must be a ___ appliance - ANSWER"Dedicated" Appliance

The "10ft-2ft-3ft" rule is a reference to what? - ANSWERIt means that chimneys
must be 3ft above the highest point of where it passes through, while still being 2ft
higher than any portion of roof within 10ft

How many feet must a type B or L vent terminate, at minimum, above the highest
connected appliance draft hood or flue collar? - ANSWER5 feet

A gas vent (B or L) must terminate atleast ___ft above a forced air inlet located
within ___ft - ANSWERA gas vent (B or L) must terminate at least 3ft above a forced
air inlet located within 10ft

Two ways CSST or copper tubing can be installed inside hollow walls or partitions if
it is concealed? - ANSWER1) Installed in single runs that are not rigidly secured

2) With steel striker barrier, minimum 16 gauge*, barrier extends 4"

*1.3mm or .0508" thick

What is the minimum pressure for a pressure test? - ANSWER1 1/2 times max
working pressure, never less than 3 psi

What is the minimum duration for a pressure test? - ANSWER10 minutes

What is the chemical formula of propane? - ANSWERC3H8

What is the specific gravity of liquid propane? - ANSWER.504

What is the specific gravity of vapor propane? - ANSWER1.50

What is the boiling point of propane? - ANSWER-44 F

What is the ignition temperature of propane? - ANSWER920 F

What is the upper flammability limit of propane? - ANSWER9.60%

What is the lower flammability limit of propane? - ANSWER2.15%

What is the combustion ratio of propane? - ANSWER24 to 1

How many BTU per cubic foot of propane vapor? - ANSWER2488 btu

,How many BTU per gallon of propane? - ANSWER91,502 btu

What is the chemical formula of natural gas? - ANSWERCH4

What is the specific gravity of liquid natural gas? - ANSWER.30

What is the specific gravity of natural gas vapor? - ANSWER.60

What is the boiling point of natural gas? - ANSWER-260 F

What is the ignition temperature of natural gas? - ANSWER1,150 F

What is the upper limit of natural gas? - ANSWER14%

What is the lower limit of natural gas? - ANSWER4%

What is the ideal combustion ratio natural gas? - ANSWER10 to 1

How many BTU per cubic foot of natural gas? - ANSWER1000 btu

What is a furnace plenum? - ANSWERA chamber constructed of duct work attached
to inlet or outlet of furnace with one or more ducts connected to it

A drip (leg) is placed where and to collect what? - ANSWERA drip (leg) is placed at
the lowest point of system piping, in order to collect condensate (which can then be
removed), should not be placed where condensate could freeze

*Also at outlet of meter in some cases

Which device would turn on or off an appliance's gas supply in response to changes
in pressure, temperature, or liquid level? - ANSWERA limit control

Condensate separates from flue gas due to either a reduction of ___ or an increase
in ___ - ANSWERCondensate is created either through a reduction of temperature
or an increase in pressure

What is the difference between a type 1 and type 2 clothes dryer? - ANSWERA type
1 dryer is for family living

A type 2 dryer is for business/public

What is a BTU? - ANSWERBritish Thermal Unit, quantity of heat needed to raise 1
pound of water 1 degree fahrenheit

What are the maximum temperature and pressure in a low pressure water boiler? -
ANSWERA low pressure water boiler has a maximum water temperature of 250 F
and pressure of 160 psi

What are the maximum pressure in a low pressure steam boiler? - ANSWER15 psi

, Two characteristics of a Category IV Vented Appliance? - ANSWER1) Positive
Pressure

2) Excessive Condensate

Two characteristics of a Category III Vented Appliance? - ANSWER1) Positive
Pressure

2) AVOIDS Excessive Condensate

Two characteristics of a Category I Vented Appliance? - ANSWER1) NON Positive
Pressure

2) AVOIDS Excessive Condensate

What is the difference between accessible and readily accessible? -
ANSWERAccessible requires removal of panel WHILE readily accessible means no
panel

Where must a sediment trap be installed, what is it made of, and what is the
minimum length? - ANSWERA sediment trap is located downstream of an appliance
shut off,

it is made of a capped nipple off a tee,

at a minimum length of 3 inches

If the height of a passageway is less than 6 feet tall, the distance from passageway
to appliance is maximum... - ANSWER20 feet

What is the minimum amount of cover for an underground piping system? And what
is an exception? - ANSWERThe minimum amount of cover is 12 inches

An exception is if there is a likely possibility of external damage, 18 inches is the
minimum cover

Why can't a 4 inch draft hood be reduced to a 3 inch vent? - ANSWERBecause in
order to reduce vent size, the draft hood must be more than 4 inches

If a draft hood outlet or flue collar is 12 inches or more, what is the maximum number
of sizes a vent can be reduced? - ANSWER2 sizes

If a draft hood outlet or flue collar is 12 inches or less, what is the maximum number
of sizes a vent can be reduced? - ANSWER1 size

What is the maximum BTU for an unvented room heater in a bathroom? -
ANSWER6,000 btu

What is the maximum BTU for an unvented room heater in a bedroom? -
ANSWER10,000 btu

Written for

Institution
PROPANE AND NATURAL GAS
Course
PROPANE AND NATURAL GAS

Document information

Uploaded on
February 19, 2025
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$17.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersbyjol West Virginia
View profile
Follow You need to be logged in order to follow users or courses
Sold
446
Member since
3 year
Number of followers
254
Documents
14151
Last sold
6 days ago

3.7

78 reviews

5
29
4
20
3
18
2
2
1
9

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions