The purpose of a draft hood/draft diverter is_______? A) To prevent drafts from entering the burner compartment that comes from the power cent hoods. B) To prevent the combustion chamber from overheating, and allowing air to come down the vent pipe into the room. C) To allow the flue to control the amount of secondary air drawn in instead of the vent pipe, and to prevent air from coming back down the vent into the combustion chamber D) To allow the vent pipe to control the amount of secondary air drawn into the combustion chamber as designed by its height above the hood. -Correct Answer C The two primary functions of the flue are____? A) The remove combustion byproducts and heat from the equipment B) To create a draft to pull in secondary air and remove the byproducts form the combustion chamber C) To create a draft to keep the burners cool and remove byproducts from the cooking area D) To remove the excessive heat to keep the burners, and cooking surface from overheating -Correct Answer B To solve unusual venting problems like negative pressure, high winds, long vents, the installe should use_____? A) A larger size vent pipe B) Vent outlets C) Vent top turbines D) A draft hood -Correct Answer D What is a bypass flame? A) The smallest flame that will keep the burners lit after the gas thermostat has reached the temperature set point B) A flame that is 3/8" tall after the thermostat shuts off C) A flame left on the burner to keep the pilot form going out D) A flame to a special part of the burner after the main burner goes off -Correct Answer A The primary purpose of a vent on a regulator is to: A) Vent leaking gas B) Allow diaphragm movement C) Allow high pressure D) Monitor flow -Correct Answer B A properly burning infrared ceramic burner will look______? A) Blue B) Bright reddish orange C) Dull red D) Blue with a tint of orange -Correct Answer B Vent lines are required on regulators above 1" and must be vented: A) A pilot flame B) An open flame within 2 feet C) A working flue or exhaust system D) The outside atmosphere, above the snow line -Correct Answer D What is the proper flame current for an ignition module? A) Always 3 or more microamps B) Always ¼ or more microamps C) It depends on the module manufacturer D) Always 2 or more microamps -Correct Answer C Primary air is the air______? A) That surrounds the burner B) That enters the burner though the venture C) Is the air that is vented through the exhaust system D) That must always have a pressure greater than the incoming gas pressure -Correct Answer B Every time a gas fired convection oven shuts off the gas flow to the burners there is a loud pop. The oven is rated for and using LP gas. The noise is called_____, and can be reduced by____ the burner air shutters more. A) Extinction pop, opening B) Delayed ignition, closing C) Delayed ignition, opening D) Extinction pop and by closing -Correct Answer D If a leak develops in an LP gas line, where is the gas likely to go? A) Out the exhaust system B) To the lowest level in the room C) Up to the ceiling area D) Out of the kitchen under the door -Correct Answer B

Content preview

Gas CFESA


Gas CFESA Practice Test Study Questions
with Answers Top Graded 2025
The purpose of a draft hood/draft diverter is_______?
A) To prevent drafts from entering the burner compartment that comes from the power
cent
hoods.
B) To prevent the combustion chamber from overheating, and allowing air to come
down the
vent pipe into the room.
C) To allow the flue to control the amount of secondary air drawn in instead of the vent
pipe,
and to prevent air from coming back down the vent into the combustion chamber
D) To allow the vent pipe to control the amount of secondary air drawn into the
combustion
chamber as designed by its height above the hood. -Correct Answer ✔C

The two primary functions of the flue are____?
A) The remove combustion byproducts and heat from the equipment
B) To create a draft to pull in secondary air and remove the byproducts form the
combustion
chamber
C) To create a draft to keep the burners cool and remove byproducts from the cooking
area
D) To remove the excessive heat to keep the burners, and cooking surface from
overheating -Correct Answer ✔B

To solve unusual venting problems like negative pressure, high winds, long vents, the
installe
should use_____?
A) A larger size vent pipe
B) Vent outlets
C) Vent top turbines
D) A draft hood -Correct Answer ✔D

What is a bypass flame?
A) The smallest flame that will keep the burners lit after the gas thermostat has reached
the
temperature set point
B) A flame that is 3/8" tall after the thermostat shuts off
C) A flame left on the burner to keep the pilot form going out
D) A flame to a special part of the burner after the main burner goes off -Correct Answer
✔A


1|Page

,Gas CFESA

The primary purpose of a vent on a regulator is to:
A) Vent leaking gas
B) Allow diaphragm movement
C) Allow high pressure
D) Monitor flow -Correct Answer ✔B

A properly burning infrared ceramic burner will look______?
A) Blue
B) Bright reddish orange
C) Dull red
D) Blue with a tint of orange -Correct Answer ✔B

Vent lines are required on regulators above 1" and must be vented:
A) A pilot flame
B) An open flame within 2 feet
C) A working flue or exhaust system
D) The outside atmosphere, above the snow line -Correct Answer ✔D

What is the proper flame current for an ignition module?
A) Always 3 or more microamps
B) Always ¼ or more microamps
C) It depends on the module manufacturer
D) Always 2 or more microamps -Correct Answer ✔C

Primary air is the air______?
A) That surrounds the burner
B) That enters the burner though the venture
C) Is the air that is vented through the exhaust system
D) That must always have a pressure greater than the incoming gas pressure -Correct
Answer ✔B

Every time a gas fired convection oven shuts off the gas flow to the burners there is a
loud pop.
The oven is rated for and using LP gas. The noise is called_____, and can be reduced
by____ the
burner air shutters more.
A) Extinction pop, opening
B) Delayed ignition, closing
C) Delayed ignition, opening
D) Extinction pop and by closing -Correct Answer ✔D

If a leak develops in an LP gas line, where is the gas likely to go?
A) Out the exhaust system
B) To the lowest level in the room
C) Up to the ceiling area

2|Page

, Gas CFESA


D) Out of the kitchen under the door -Correct Answer ✔B

The approximate amount of BTU's produced by burning one cubic foot of natural gas is?
A) 10,000
B) 2500
C) 750
D) 1000 -Correct Answer ✔D

The normal operating pressure of LP gas is_____?
A) 10-15 psi
B) 3-7 psi
C) 10-11 in WC"
D) 3-7 in WC" -Correct Answer ✔C

The normal operating pressure of a typical natural gas type burner is approximately:
A) 15-25 psi
B) 3-4 psi
C) 10-11 in WC"
D) 3.5-7 in WC" -Correct Answer ✔D

Make up air is:
A) The air that enters the venture of the burner
B) The air that mixes with the gas at the burner ports
C) The air that enters the room from the outside
D) The air that is taken out through the vent -Correct Answer ✔C

LP gas, at the appliance, is_______?
A) Heavier than air
B) Light yellow
C) Lighter than air
D) Odorless -Correct Answer ✔A

Ideally to burn one cubic foot of LP gas approximately______ cubic feet of air is
required.
A) 100
B) 24
C) 10
D) 44 -Correct Answer ✔B

Natural gas coming out of a gas line piped into a building is:
A) Heavier than air
B) Light yellow
C) Lighter than air
D) Odorless -Correct Answer ✔C


3|Page

Document information

Uploaded on
February 18, 2025
Number of pages
20
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PossibleA
3.9
(149)
Sold
1063
Followers
651
Items
13881
Last sold
10 hours ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions