100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

A/C Study guide HVAC TCAT Exam 2025/2026 Questions With Completed & Verified Solutions.

Rating
-
Sold
-
Pages
9
Grade
A+
Uploaded on
14-02-2025
Written in
2024/2025

A/C Study guide HVAC TCAT Exam 2025/2026 Questions With Completed & Verified Solutions.

Institution
AC-HPAT
Course
AC-HPAT









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
AC-HPAT
Course
AC-HPAT

Document information

Uploaded on
February 14, 2025
Number of pages
9
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

A/C Study guide HVAC TCAT

_____ can be used for leak detection and is safe with all refrigerants - ANS Soap/bubble
solution
\10lbs of refrigerant pass through a water cooled condenser and gives up 20 BTU's of
heat per lb. At the same time, 10lb of water passes through with an entering temperature
of 80 degrees Fahrenheit the temperature of the water leaving the condenser is - ANS 100
Degrees Fahrenheit
\a clear sight glass could indicate
A)all liquid refrigerant
B)no refrigerant
C)either A or B
D) neither A nor B - ANS C)either A or B
\a compound pressure gauge measures - ANS pressure and vacuum
\a compressor that has a broken valve cause these symptoms
A)high suction pressure and low discharge pressure
B)high suction pressure and high discharge pressure
C)low suction pressure and low discharge pressure
D)low suction pressure and high discharge pressure - ANS A)high suction pressure and
low discharge pressure
\a condenser that is used in low ambient temperature conditions must have a method of
maintain a workable head pressure. This can be accomplished by
A)fan cycling
B)air shutters or dampers
C)condenser flooding
D)any of the above - ANS D)all of the above
\a customer calls on the first hot day in the spring and complains of no cooling. Upon
inspection your find that the sight glass indicates a full charge, the liquid line is hot, and
the unit is cycling on the motor internal overloads. this could be caused by
A)an overcharge of refrigerant
B)a dirty condenser
C)an inoperative condenser fan
D)any of the above - ANS D)any of the above
\a customer complains that their air conditioning system is running constantly, but not
cooling enough. the suction line is very cold and the compressor is sweating

TECH A says this could be caused by low refrigerant charge and needs to be leak tested
and repaired.

TECH B says that these symptoms could indicate restricted return air flow or a dirty
evaporator. Whos correct?

, A)tech a
B)tech b
C)both
D)neither - ANS B)tech B
\a customer reports that their residential split system had a compressor replaced last
week by another service company. now the unit is not cooling properly. when you arrive
and inspect the unit, you find that the condensing unit, you find that the liquid line is
sweating where it leaves the drier. this is most likely the result of - ANS debris from the
burned out compressor has a clogged the drier
\a decrease in superheat causes the thermostatic expansion valve to
A)open
B)close
C)fail
D)none of the above - ANS B)close
\a dirty evaporator in an air conditioning system will cause these symptoms
A)high suction pressure and low discharge pressure
B)high suction pressure and high discharge pressure
C)low suction pressure and low discharge pressure
D)low suction pressure and high discharge pressure - ANS C)low suction pressure and
low discharge pressure
\a faulty condenser fan motor on an air conditioning system will cause these symptoms
A)high suction pressure and low discharge pressure
B)high suction pressure and high discharge pressure
C)low suction pressure and low discharge pressure
D)low suction pressure and high discharge pressure - ANS B)high suction pressure and
high discharge pressure
\a hermetic system that is low on charge is indicated by
A)a partially frosted evaporator
B)low head pressure
C)low suction pressure
D)all of the above - ANS D)all of the above
\a liquid line filter-drier should be placed - ANS between the condenser and the metering
device
\a liquid receiver is used - ANS to store liquid refrigerant
\a liquid-to-suction heat exchanger is often used to - ANS increase sub-cooling
\a low pressure cut-off switch is used to - ANS establish a minimum operating pressure
in the evaporator
\a low refrigerant charge in the air conditioning system will cause these symptoms
A)high suction pressure and low discharge pressure
B)high suction pressure and high discharge pressure
C)low suction pressure and low discharge pressure
D)low suction pressure and high discharge pressure - ANS C)low suction pressure and
low discharge pressure
\a low-side float metering device is used; - ANS on a flooded evaporator

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LEWIS12 Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
23
Member since
1 year
Number of followers
1
Documents
1013
Last sold
5 days ago

3.3

3 reviews

5
1
4
0
3
1
2
1
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions