Questions and Answers
1. The inspector is not required to determine
u u u u u u u
of any system or component.: -Years of age
u u u u u u u
-Life expectancy u
-Make model u
2. Horizontal waste pipe should slope inch per foot: 1/4" per foot if < 3 inch pipe.
u u u u u u u u u u u u u u u
1/8" per foot if > or = to 3 inch pipe
u u u u u u u u u u
3. Drip screed: Also called weep screed.
u u u u u
Used at the base/bottom of stucco walls to release moisture.
u u u u u u u u u
4. Pressure Vacuum Breaker (PVB): Used for Backflow Prevention.
u u u u u u u
Lawn Irrigation systems: installed vertically 6 to 12 inches above highest outlet/emit-
u u u u u u u u u u u
uter and before the irrigation system valves.
u u u u u u
5. Lintel: L shaped steel installed to support brick veneer above openings such as windows
u u u u u u u u u u u u u u
and doors. u
Should bear on 6 inches or greater of the supporting veneer. Rusted lintels
u u u u u u u u u u u u u
may expand and cause cracks around openings.
u u u u u u
6. Guardrail for decks and patios: A deck 30" above grade requires a guardrail. Required if
u u u u u u u u u u u u u u u
deck is > or = to 30 inches above grade.
u u u u u u u u u
Balusters and openings should not exceed 4 inches in diameter. Rail height
u u u u u u u u u u u u
must be > or = to 36 inches from deck.
u u u u u u u u u
7. Minimum overlap on vertically installed fiber cement siding: 1 1/4 inches overlap, a
u u u u u u u u u u u u
nd blind nailing recommended
u u u
8. Distance required between wall cladding and roof covering materials?: 1" to 2" (1 inch m
u u u u u u u u u u u u u u
inimum, some local code is 2") u u u u u
9. What is the concern with a Double sided key lock deadbolt: All means of egress (esc
u u u u u u u u u u u u u u u
ape), must be operable from the inside without special knowledge or tools. A keyed lock i
u u u u u u u u u u u u u u u
s a danger.
u u
10. Fiberglass shingle roof that is 5 years old is losing granular and cupping. Attic insulati
u u u u u u u u u u u u u u
1u/u82
,on and venting is adequate. What is the most reasonable expla-
u u u u u u u u u u
nation?: Improper installation. Sealing strip or nailing was not done properly.
u u u u u u u u u u u
11. What is the last part to fail in a slate roof system?: The slate itself. Flashings eventually
u u u u u u u u u u u u u u u u u
wear out, but long before the slate.
u u u u u u
12. Metal roof has minor rust in spots.What is the corrective action?: Removing the rust, pri
u u u u u u u u u u u u u u u
ming and painting.
u u
13. What type of flashing is found on a gable edge?: Rake edge or edge flashing. A gable Edge
u u u u u u u u u u u u u u u u u
is called a rake.
u u u u
14. Which construction framing provides fire blocking?: a platform-framed structure
u u u u u u u u
2u/u82
,15. The Bottom chords of trusses were cut to fit other construction. What is the recom
u u u u u u u u u u u u u u
mendation?: Recommend a structural engineer . u u u u u
16. What purpose does a barometric damper serve?: To control the draft
u u u u u u u u u u
17. Water is dripping from discharge piping coming from a hydronic heating system. Wh
u u u u u u u u u u u u
at is most likely the cause?: A leak
u u u u u u u
18. Masonry Chimney is required to be u u u u u u
inches from wood framing in the attic?: 2"
u u u u u u u
19. When new insulation is placed directly over old in the attic, what is the correct way t
u u u u u u u u u u u u u u u u
o place / handle Kraft paper on new insulation?: Score or remove the vapor paper
u u u u u u u u u u u u u u
20. What two structural components would be tied together with hurricane ties?: Trus
u u u u u u u u u u u
s/rafter to the top of walls
u u u u u
21. What type of piping is used for a pool circulation system?: Schedule 40 PVC
u u u u u u u u u u u u u
22. Does the main water supply shutoff have to be above grade, below grade, or accessib
u u u u u u u u u u u u u u
le?: Accessible ?
u u
23. Distance between interior electrical receptacles?: 12'
u u u u u
24. A wood burning furnace should be how far away from combustibles: 18"
u u u u u u u u u u u
25. Dishwasher drain line is installed where in reference to the trap?: Above
u u u u u u u u u u u
26. stairs, staircase tread depth: Tread depth should be a minimum of 10 inches. 11 inches
u u u u u u u u u u u u u u u
if there is no nosing.
u u u u
The difference between any two riser heights, treads or nosing in a flight of stairs should be no
u u u u u u u u u u u u u u u u u
more than 3/8ths of an inch
u u u u u
27. Staircase Nosing projection: Nosing should project between 3/4th inch and 1 1/4th inch
u u u u u u u u u u u u
The difference between any two riser heights, treads or nosing in a flight of stairs should be no
u u u u u u u u u u u u u u u u u
more than 3/8ths of an inch
u u u u u
28. Staircase Riser height: Riser height should be 7 3/4th inches maximum The differenc
u u u u u u u u u u u u
e between any two riser heights, treads or nosing in a flight of stairs should be no more tha
u u u u u u u u u u u u u u u u u u
n 3/8ths of an inch
u u u u
29. Stair stringers and width: Stairs wider than 36 inches should have at least three strin
u u u u u u u u u u u u u u
gers
30. Spiral staircase: Tread depth should be a minimum of 7 1/2 inches, measured 12 inches
u u u u u u u u u u u u u u
ufrom the narrow side.
u u u
3u/u82
, Riser height should be 9 1/2 inches maximum. Minimum widt
u u u u u u u u u
h is 26 inches at / below the handrail
u u u u u u u u
31. Hearth size requirements for greater than and smaller than 6 square feet: 6' opening -
u u u u u u u u u u u u u u
16" in front and 8" sides
u u u u u u
4u/u82