Halons were completely phased out by ______ :
1994
1995
1987
2000 - ANS- 1994
Recovered refrigerant is stored in which of the following painted tank:
Gray with yellow top
Yellow with gray top
Yellow with blue top
Blue with yellow top - ANS- Gray with yellow top
If your recovery unit does not have a sub-cooling feature recovery rate will be _____ :
Recovery rate is independent
Slower
Faster - ANS- Slower
TXV valve maintaining the pressure difference between _____ and _____ of the system
Expansion valve, Evaporator
Condenser, Evaporator
Compressor, Condenser
,Evaporator, Compressor - ANS- Condenser, Evaporator
After recovering refrigerant from a sealed system, which of the following gas is used to
pressurize (for leak checking) or blow debris out of the system:
Hydrogen
Carbon dioxide
Oxygen
Nitrogen gas - ANS- Nitrogen gas
Which one of the following has highest Ozone Depletion Potential (ODP):
HCFC
All will have same ODP
CFC
HFC - ANS- CFC
The ____connects the evaporator to the compressor in a refrigerant system:
Suction Line
Evaporation Line
Discharge Line
Liquid Line - ANS- Suction Line
A violation of the Clean Air Act, including improper record keeping, is subject to a penalty of a
fine of up to _____ per day per violation:
$37,500
$40,000
$24,000
$35,000 - ANS- $37,500
At which of the following stage in refrigeration cycle does the refrigerant changes from
high-pressure vapor to a high-pressure liquid:
Evaporator
Condenser
Compressor
Expansion valve - ANS- Condenser
Which of the following is not most effective way to detect the general area of a small leaks:
fluorescent Indicator
Ultrasonic tester
All the options are correct
Electronic tester - ANS- fluorescent Indicator
During each vacuum decay test, it is observed that after creating the vacuum, the pressure of
the system increases to greater than 0 psig and stops at some point, Then:
,Leak could not be observed
Leak is observed but not refrigerant is trapped
None of the answers are correct
The refrigerant could be trapped in the system - ANS- The refrigerant could be trapped in
the system
Refrigerant cannot be called reclaimed unless it meets the ______ purity standard:
ARI-700
ARI-740
ARI-360
ARI-1024 - ANS- ARI-700
One chlorine atom in stratosphere can be able to destroy approximately _______ number of
ozone molecules:
100,000
10,000
1000
100 - ANS- 100,000
It is to be ensured that the refrigerant recovery cylinder is not filled to more than _____ of its
capacity
90 percent
60 percent
50 percent
80 percent - ANS- 80 percent
Only _____ refrigerant can be transferred or sold to another individual
Disposed
Reclaimed
Recovered
Recycled - ANS- Reclaimed
Lifetime of CFCs is believed to be in the range ______ :
Above 1000 years
5 to 10 years
100 to 500 years
20 to 100 years - ANS- 20 to 100 years
EPA has divided refrigerated appliances into _____ groups
Six
Three
Four
Five - ANS- Five
, Which of the following substance present in refrigerant appliance results in corrosion:
Can be either acidic and basic
Basic
Acidic - ANS- Acidic
A recovery cylinder can maximum store _____ number of refrigerants:
One
Three
Four
Two - ANS- one
A vacuum test could actually hide a leak:
False
True - ANS- True
Presence of which of the following element will reduce the stability of the ozone depletion
organic refrigerant compounds:
Hydrogen
Chlorine
Bromine
All options are correct - ANS- Hydrogen
The ______ connects the condenser to the expansion device:
Discharge line
Suction line
Liquid line
Expansion line - ANS- Liquid Line
_____ breaks down the CFCs and frees the chlorine ion at stratosphere:
Ultraviolet radiation
Gamma radiation
Infrared radiation
X-radiation - ANS- Ultraviolet Radiation
Refrigeration technicians who violate the Clean Air Act may:
Required to appear in federal court.
All the options are correct
Lose their EPA certification
Be fined - ANS- All the options are correct