True or false weld sizes, links, and location of Welds shall conform to the requirements of the
part B book of specifications - Answer✔true
According to the pressure piping clause, linear indications greater than 3/16 inch long are
unacceptable. true or false - Answer✔true
on a pipeline what is the aggregate length of incomplete Fusion or IF that is considered a defect
when the weld length is less than 12 inches - Answer✔when it exceeds 8% of the weld length
what is the abbreviation for cracks? - Answer✔C
A welder who qualifies on a butt weld with backing is qualified to a weld __________ -
Answer✔A weld that is going to be back gouged on the backside of the groove Weld and then
back welded.
A weld with a backing strip.
A weld with a backing weld with deposited first.
failure of any portion of a single test weldment for performance qualification constitutes failure
for - Answer✔welders use in the test
the welding procedure qualification record may be presented in which format? -
Answer✔tabular or written
a weld in a Groove weld in a butt joint that is transverse to the direction of computed tensile
stress in a statically loaded non tubular Connection in a structural steel application is allowed
how much visible porosity? - Answer✔none
what should an inspector do if it is noted that the welder taking the test is not exhibiting the
necessary skills? - Answer✔Terminate the test at any stage that they demonstrate in
competency