InternationalResidentialCodeMasterSetExamQuestions& Answers. IRC Permit not required for a one story detached accessory structure ( Tool Shed ) provided the floor area des not exceed - Correct Answer 120 Sq feet IRC Permit not required for retaining walls that are not over ? feet in height unless supporting a surcharge - Correct Answer 4 Feet IRC Final inspection shall be made after permitted work is ___ and prior to ___ - Correct Answer Complete Occupancy IRC Building permit or copy shall be kept on site of work untill ? of the project - Correct Answer Completion IRC A wall supporting any vertical load in addition to its own weight is a ___ wall - Correct Answer Load Bearing

Content preview

International Residential Code Master Set Exam Questions &
Answers.
IRC
Permit not required for a one story detached accessory structure ( Tool Shed ) provided the
floor area des not exceed - Correct Answer 120 Sq feet

IRC
Permit not required for retaining walls that are not over ? feet in height unless supporting a
surcharge - Correct Answer 4 Feet

IRC
Final inspection shall be made after permitted work is ___ and prior to ___ - Correct
Answer Complete

Occupancy

IRC
Building permit or copy shall be kept on site of work untill ? of the project - Correct Answer
Completion

IRC
A wall supporting any vertical load in addition to its own weight is a ___ wall - Correct
Answer Load Bearing Wall

IRC
Hot water is water at a temperture greater than or equal to ___ - Correct Answer 110
Degree F

IRC
Signifies access that requires the removal of an access panel or similar removable
obstruction - Correct Answer Accessabile

IRC
On stairways the maximum riser height shall be - Correct Answer 7 3/4 Inch

IRC
Stairways shall not be less than ___ inches in clear width at all pionts above the permitted
handrail height and below the required headroom height - Correct Answer 36 Inches

IRC
A Minimum ___ x ___ foot landing shall be provided:

1) At the top and bottom of ramps
2) Where the doors open onto ramps

,3) Where ramps change direction - Correct Answer 3 feet x 3 feet

IRC
Every landing will have a minimum dimension of ___ inches measured in durection of
travel - Correct Answer 36 Inches

IRC
There shall be a floor or ___ at the top and bottom of each stairway - Correct Answer
Landing

IRC
Where openings are provided as a means of escape and rescue they shall have a sill
height of not more than ___ inches above floor - Correct Answer 44 Inches

IRC
Garage shall be seperated from the residence and its attic area by not less than ___ inch
gypsum board or equivalent applied to the garage side - Correct Answer 1/2 Inch

IRC
Openings from a private garage directly into a room used for sleeping purposes shall ___
be permitted - Correct Answer Not

IRC
Glazing in swinging doors ( except jalousies ) shall be considered a ___ location - Correct
Answer Hazardous

IRC
Showers and bathtubs with installed shower heads shall be finished with a nonabsorbent
surface , that shall extend to a height of not less than ? feet above the floor - Correct
Answer 6 Feet

IRC
Each dwelling unit shall be provided with a kitchen area and every kitchen area shall be
provided with a ___ - Correct Answer Sink

IRC
Every dwelling unit shall be provided with a :
Water closet
Lavatory
Bathtud or shower - Correct Answer True

IRC
Dwelling units shall be provided with heating facilities capable of maintaining a minimum
room temperture of ___ - Correct Answer 68 Degree F

IRC

, Bathrooms shall be provided with aggregate glazing area in windows of not less than ___
sq feet , one half of which must be openable - Correct Answer 3 Sq Feet

IRC
Minimum openable area to the outdoors shall be ___ % of the floor being ventilated -
Correct Answer 4 %

IRC
Exterior walls with a fire seperation distance less than ___ feet shall have not less than one
hour fire resistive rating with exposure from both sides - Correct Answer 5 Feet

IRC
In areas subject to decay damage , naturally durable wood or wood that is preservative
treated shall be used - Correct Answer True

IRC
Dwelling units in two-family dwellings shall be seperated from each other by wall and/or
floor assemblies of not less than ___ hour fire rating - Correct Answer 1 Hour

IRC
Required smoke alarms shall recieve there primary power from the building wiring , and
when primary power is interupted , shall recieve power from a ___ - Correct Answer
Battery

IRC
Smoke alarms shall be required in the following locations :

* In each sleeping room
* Adjacent to each bedroom
* On each story of the dwelling - Correct Answer True

IRC
Required guards on stairways and porches shall be constructed to not allow passage of a
___ inch diameter sphere - Correct Answer 4 Inches

IRC
Minimum headroom in all parts of the stairway shall not be less than _____ Feet , ______
Inches - Correct Answer 6 Feet - 8 Inches

IRC
On stairways the greater riser height within any flight of stairs shall not exceed the smallest
by more than ___ inch - Correct Answer 3/8 Inch

IRC
On stairways the greater tread depth within any flight of stairs shall not exceed the smallest
by more than ___ inch - Correct Answer 3/8 Inch

Document information

Uploaded on
January 28, 2025
Number of pages
19
Written in
2024/2025
Type
Exam (elaborations)
Contains
Unknown
$18.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Pronurse
3.4
(34)
Sold
159
Followers
141
Items
8225
Last sold
1 week ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions