Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits 2025 SOLUTION AID GRADE A+
Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits 2025 SOLUTION AID GRADE A+ According to the NEC®, the ampacity of branch circuit conductors must be derated when there are more than how many current-carrying conductors in a raceway? 3 Air conditioning overcurrent protective devices can never exceed what percentage of the motor-rated load current or the branch circuit selection current (whichever is greater)? 225% Conductors must be derated when installed in conduit on or above rooftops Continuous loads are calculated at what percentage of the maximum current rating of the overcurrent device? 80% For a given load and length, the branch circuit voltage drop should not exceed 3% For resistance welders, the rating for the overcurrent protection device should not exceed what percentage of the primary current rating of the welder? 300% Show window lighting is calculated at 200VA per linear foot plus 125% The allowable ampacity for eleven No. 12 THHN copper conductors in a cable must be adjusted by 50% The load for 10' of multi-outlet assembly used to supply several loads simultaneously is 1,800VA The maximum size dual-element fuse for a 40hp, 3Ø, 460V motor with a Design Letter D is 100A What is the demand load for one household range with a nameplate rating of 11.75kW, 240V, 1Ø? 8kW What is the current-carrying capacity for No. 6 THWN aluminum conductors in conduit run through an ambient temperature of 38°C? 44 Amps What is the lighting load on a 120V circuit for six 100W incandescent lights and four fluorescent fixtures with a ballast rating of 1.5A, all operating continuously for 8 hours per day? 13.75A 13.75A What is the load center distance for a 208V, four-wire, three-phase branch circuit with fixed noncontinuous loads from the source of 60A at 45', 40A at 60', 30A at 75', and 25A at 100' 63.55' What is the load center length for a branch circuit consisting of noncontinuous loads of 125A at 80', 75A at 110', and 50A at 100'? 93' What is the load center length for a branch circuit with noncontinuous loads of 20A at 60' and 50A at 125'? 106.43' What is the load for 55' of show window using the linear foot method? 13,750VA What is the motor full-load current for a motor with a nameplate rating of 50hp, 460V, 3Ø? 65A What is the required circuit ampacity of a noncontinuous, single-phase load of 8.5kW at 277V?
Written for
- Institution
- Electrical Level 3 Module 1 Load Calculations and
- Course
- Electrical Level 3 Module 1 Load Calculations and
Document information
- Uploaded on
- January 27, 2025
- Number of pages
- 2
- Written in
- 2024/2025
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
electrical level 3 module 1 load calculations and
-
according to the nec the ampacity of branch circ
-
conductors must be derated when installed in condu
-
for a given load and length the branch circuit vo