This type of water heater ventilation system uses the natural upward movement of airflow to filter exhaust gases up and out of the home. correct answers atmospheric ventilation system The shutoff valve for a gas water heater's supply line may not be more than _____ feet from the water heater. correct answers 6 Water heaters must be installed in a location that has a level working space that is at least _____ inches long and _____ inches wide. correct answers 30, 30 Water heaters that use a gas fuel source may not be located in a room with _____ machinery. correct answers air-handling Chimney Cap correct answers mounted above the crown, preventing water, birds, small animals, and debris from getting inside the chimney while allowing smoke and gas to escape. Chimney Crown correct answers the top level of the chimney, with a sloped surface directing much of the water away from the chimney Spark arrestor correct answers mesh covering that stops sparks and embers from leaving the chimney. Irrigation systems conserve water by the use ___ ____ or ___ ___ sensors (SMS). correct answers rain sensors, soil moisture What 2 components are in a zone for a sprinkler system? correct answers valve, sprinkler head What is a backflow preventor? correct answers Stops water contaminated from pesticides, fertilizers, or other chemicals from entering the home's supply of drinking water by allowing water to flow only one way What are 2 possible locations for the irrigation system's shut-off valve? correct answers below backflow preventor or underground, in line with water supply Four types of well pumps: correct answers shallow well jet, centrifugal, deep well jet, deep well submersible Pressure switch correct answers senses water pressure and turns the pump off and on and is normally mounted on piping at the water pressure tank. Two types of septic systems: correct answers conventional, alternative

Content preview

NHIE and AHIT Exam Questions || with 100% Verified
Solutions.
This type of water heater ventilation system uses the natural upward movement of airflow to
filter exhaust gases up and out of the home. correct answers atmospheric ventilation system

The shutoff valve for a gas water heater's supply line may not be more than _____ feet from the
water heater. correct answers 6

Water heaters must be installed in a location that has a level working space that is at least _____
inches long and _____ inches wide. correct answers 30, 30

Water heaters that use a gas fuel source may not be located in a room with _____ machinery.
correct answers air-handling

Chimney Cap correct answers mounted above the crown, preventing water, birds, small animals,
and debris from getting inside the chimney while allowing smoke and gas to escape.

Chimney Crown correct answers the top level of the chimney, with a sloped surface directing
much of the water away from the chimney

Spark arrestor correct answers mesh covering that stops sparks and embers from leaving the
chimney.

Irrigation systems conserve water by the use ___ ____ or ___ ___ sensors (SMS). correct
answers rain sensors, soil moisture

What 2 components are in a zone for a sprinkler system? correct answers valve, sprinkler head

What is a backflow preventor? correct answers Stops water contaminated from pesticides,
fertilizers, or other chemicals from entering the home's supply of drinking water by allowing
water to flow only one way

What are 2 possible locations for the irrigation system's shut-off valve? correct answers below
backflow preventor or underground, in line with water supply

Four types of well pumps: correct answers shallow well jet, centrifugal, deep well jet, deep well
submersible

Pressure switch correct answers senses water pressure and turns the pump off and on and is
normally mounted on piping at the water pressure tank.

Two types of septic systems: correct answers conventional, alternative

, In a conventional septic system, sludge and scum remain in the tank, and the liquid called ____
leaves the tank. correct answers effluent

A ___ ___ is a network of perforated pipes in trenches or beds of gravel. correct answers drain
field

For ranges, vent hood ducts must (3): ___, ___, and ___. correct answers terminate outside the
home, have a smooth interior surface and be constructed of (galvanized steel, stainless steel, or
copper), and be airtight

What 3 things can prevent cross connections at some equipment and fixtures: correct answers
anti-siphon devices, vacuum breakers, air gaps

S-traps can be converted to a vented P-trap through the use of an: correct answers air admittance
valve

This type of meter was installed in the last 20 years. They're usually compatible with 200 amp
service, although there are exceptions. correct answers Rectangular-base meters

UL stands for: correct answers Underwriters Laboratory

This type of meter was installed 50 or more years ago. They were originally rated for 60 amps.
Later generations of round-base meters were rated at 100 amps. correct answers Round-base
meters

This type of meter was installed 40 or more years ago. They were normally rated at 100 amps,
with later generations sometimes rated at 125 amps. correct answers Square-base meters

The ____ ____ are the wires coming into the home from the utility company's meter. They can
be copper, aluminum, or copper-clad aluminum. correct answers service conductors

Which two types of service conductors require the same gauge for a given amperage rating?
correct answers aluminum and copper-clad aluminum

True or False: An electrician should always be called to evaluate aluminum branch circuit
wiring. correct answers True

Grounded or Ungrounded: Until the 1960s most electrical receptacles were _____ . They only
had 2 slots in them for appliance plugs with two prongs. correct answers ungrounded

At three-pronged receptacles, when the ground wire is not connected to the receptacle ground
screw or there is no ground wire as in an older home, it is called an: correct answers open ground

Dimmer switches run _____ than standard switches. (Hotter or Colder) correct answers Hotter

Document information

Uploaded on
January 27, 2025
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$11.19

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SirAnton
3.7
(117)
Sold
788
Followers
438
Items
39564
Last sold
6 days ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions