What device is used to prevent refrigerant migration to the compressor during
the off cycle? - ANSWER>>Crankcase Heater

What is the purpose of a suction line accumulator? - ANSWER>>Prevents liquid
refrigerant from entering the compressor

Electric resistance heaters operate more efficiently than a heat pump -
ANSWER>>False

What are the 4 basic types of heat pumps? - ANSWER>>Air-Air
Water-water
water-air
ground-air

A heat pump can provide both _____ and _____ by moving heat with refrigerant.
- ANSWER>>Heating and cooling

The electrical windings of a single phase compressor may be checked with an
ohmmeter, which of the following would provide the highest reading? -
ANSWER>>Run to start

When using the manifold gauge set the compound gauge must... -
ANSWER>>Never be connected to the high side of the system

Water to water heat pumps use less electricity than the other systems when they
are properly maintained - ANSWER>>False

Air to air systems are the most popular type of heat pump - ANSWER>>True

,A compressor has been off all winter, upon checking it you find it is warm. This is
most likely because... - ANSWER>>the crankcase heater is on

Auxiliary heat strips are used on heat pumps to aid the system when the outdoor
temp drops below the balance point. - ANSWER>>True

Solid state defrost is one of the most popular methods of defrost initiation and
termination. - ANSWER>>True

Absolute zero on the kelvin scale is... - ANSWER>>-459 degree Fahrenheit

What is used to bring heat from the source to the building? -
ANSWER>>Refrigerant

What device reverses refrigerant flow? - ANSWER>>Reversing valve

What type of heat pump is most efficient? - ANSWER>>Water to water

What are the 2 ways of rating heat pump efficiency? - ANSWER>>COP and SEER

What are the 2 most popular defrost control systems? - ANSWER>>Time/Temp
and solid state

The basic concept of a heat pump is to ____ the refrigerant flow from cooling and
heating modes. - ANSWER>>Reverse

During the off cycle, what does the compressor pump into? - ANSWER>>Outdoor
coil

During the heating cycle, which coil does the compressor pump refrigerant from?
- ANSWER>>Outdoor coil

, What is the last component in the system refrigerant enters before entering the
compressor? - ANSWER>>Suction line accumulator

What components direct the refrigerant around the flow control device(s) used
ion a heat pump? - ANSWER>>Check valve

What is the purpose of the defrost cycle on a heat pump system? -
ANSWER>>Remove frost build up

In the heat pump heating mode, a dirty filter can result in: - ANSWER>>Excessive
head pressure

In comparison to the ON cycles of conventional hot air heating equipment, the ON
cycles of the heat pump during the heating mode are: - ANSWER>>About the
same

Across a suction line drier, how much pressure drop dictates changing the drier -
ANSWER>>3 psig

Which of the following is likely to cause flooding of the evaporator coil on a
system that is using a capillary tube metering device - ANSWER>>An evaporator
with low air flow

In a refrigeration system, the presence of air is indicated by... - ANSWER>>High
head and normal suction pressures

Through what component(s) is the direction of refrigerant vapor flow reversed
when the cycle is reversed from heating and cooling in a heat pump installation? -
ANSWER>>The evaporator and condenser

What component must always be de-energized during the defrost cycle? -
ANSWER>>The outdoor fan

Document information

Uploaded on
January 22, 2025
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$18.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
5
Followers
0
Items
1316
Last sold
6 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions