SPRINKLER STUDY GUIDE All work performed on any component of a fire sprinkler system MUST be done by or under the supervision of a - Answer-G. Card holder Quarterly Inspections MUST be done by a - Answer-License holder or designee Service Tags SHALL be hung on the - Answer-OS&Y valve after work is completed The minimum number of heads in a box is - Answer-Six The maximum working pressure of a fire sprinkler system is - Answer-175psi A dry pipe valve and supply pipe SHALL be protected from - Answer-Freezing How much notice must be given to the AHJ before a test or inspection can be scheduled? - Answer-48 hours When a fire sprinkler system has more than 20 sprinkler heads a - Answer-Fire alarm is required A fire sprinkler system MUST take no longer than _______ for water to reach the most remote head - Answer-3 minutes What is the minimum residual pressure required for a light hazard fire sprinkler system? - Answer-15psi The air pressure over the anticipated trip pressure of a dry fire sprinkler system should not exceed - Answer-20psi The maximum length of lateral sway bracing on a cross main is - Answer-40 feet Pipe hangers SHALL be designed to hold the weight of the pipe filled with water plus - Answer-250lbs at the point of the hanger The all thread required to hang 5, 6 & 8 inch pipe is - Answer-1/2" Fire sprinkler system piping SHALL be tested at 200psi for - Answer-2 hours The water gauge SHALL be placed above and below the - Answer-Alarm check valve E.S.F.R (early suppression fast response) sprinkler heads are NOT allowed in - Answer-Dry systems Maintenance and inspection of fire sprinkler systems is found in - Answer-NFPA 25 T or F : NFPA 13 is for design, installation and water supply only - Answer-False Upright head frames MUST be installed ________ to branch lines - Answer-Vertical Maximum temperature of water inside a fire sprinkler pipe - Answer-120 Degrees A Contractor has ________ to deliver paperwork to the Owner after inspections - Answer-30 Days The State Fire Marshal gets the above ground and underground - Answer-Contractors Material Test Certificate (CMT) The maximum time allowed to pump up a dry sprinkler system is - Answer-30 minutes Torch cutting or welding in the field is - Answer-Not allowed Welding is _________ of joining Fire Sprinkler Pipe together - Answer-An approved means Type M. Copper _________ be bent - Answer-Cannot Distance between fire sprinkler heads is measured from - Answer-Center of head to center of head T or F: Every Fire Sprinkler System requires 2 water supplies - Answer-False All Fire Sprinkler Escutcheons ___________ for the head type - Answer-Must be Listed A company MUST give __________ to cancel an inspection - Answer-30 days notice When is it required to submit plans when remodeling an existing system? - Answer-Always The minimum number of sprinkler heads required to be monitored is - Answer-20 heads All sprinkler systems MUST be tested for - Answer-1 Hour at 50% above pressure The top of a Riser MUST be secured with a - Answer-4 way brace T or F: An auxiliary drain is Required where a change of direction prevents draining through the main drain - Answer-True Minimum distance between side wall fire sprinklers is - Answer-6 Feet Commercial cooking equipment spray nozzles MUST be replaced - Answer-Annually T or F:: The FDC is tied into the System Side of the riser alarm check - Answer-True The Minimum distan

Content preview

SPRINKLER STUDY GUIDE
All work performed on any component of a fire sprinkler system MUST be done by or
under the supervision of a - Answer-G. Card holder

Quarterly Inspections MUST be done by a - Answer-License holder or designee

Service Tags SHALL be hung on the - Answer-OS&Y valve after work is completed

The minimum number of heads in a box is - Answer-Six

The maximum working pressure of a fire sprinkler system is - Answer-175psi

A dry pipe valve and supply pipe SHALL be protected from - Answer-Freezing

How much notice must be given to the AHJ before a test or inspection can be
scheduled? - Answer-48 hours

When a fire sprinkler system has more than 20 sprinkler heads a - Answer-Fire
alarm is required

A fire sprinkler system MUST take no longer than _______ for water to reach the
most remote head - Answer-3 minutes

What is the minimum residual pressure required for a light hazard fire sprinkler
system? - Answer-15psi

The air pressure over the anticipated trip pressure of a dry fire sprinkler system
should not exceed - Answer-20psi

The maximum length of lateral sway bracing on a cross main is - Answer-40 feet

Pipe hangers SHALL be designed to hold the weight of the pipe filled with water plus
- Answer-250lbs at the point of the hanger

The all thread required to hang 5, 6 & 8 inch pipe is - Answer-1/2"

Fire sprinkler system piping SHALL be tested at 200psi for - Answer-2 hours

The water gauge SHALL be placed above and below the - Answer-Alarm check
valve

E.S.F.R (early suppression fast response) sprinkler heads are NOT allowed in -
Answer-Dry systems

Maintenance and inspection of fire sprinkler systems is found in - Answer-NFPA 25

T or F : NFPA 13 is for design, installation and water supply only - Answer-False

Document information

Uploaded on
January 19, 2025
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Freshy
3.6
(10)
Sold
62
Followers
4
Items
6986
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions