EEG BOARD PREP 2025 QUESTIONS AND ANSWERS 100% PASS The EEG amplifier is designed so that when input 1 is more negative than input 2, the deflection will be - UPWARD Common Mode Rejection - the characteristic of an amplifier that rejects external interference WHICH OF THE FOLLOWING IS MOST ATTENUATED BY A LOW FREQUENCY FILTER OF 1HZ - 0.1 HZ TIME CONSTANT IS DEFINED AS THE TIME REQUIRED TO... - FOR THE DEFLECTION TO FALL (DECAY) TO 67% OF THE PEAK DEFLECTION An EEG record has 3/sec spike & wave discharges. Both the spike and the slow wave have voltages of 100uV. If this discharge is recorded with a LFF of 5Hz and a sensitivity of 10uV/mm, what would be the deflection of the spike and the wave? a. spike 10mm & wave 6mm b. spike 6mm & wave 10mm c. spike 10mm & wave 10mm 2Katelyn Whitman, All Rights Reserved © 2025 d. spike 6mm & wave 6mm - SPIKE 10MM, WAVE 6MM A HIGH FREQUENCY SETTING OF 35HZ WOULD ATTENUATE 50HZ MUSCLE ACTIVITY BY APPROXIMATELY WHAT PERCENTAGE? - 40% ACCORDING TO ACNS GUIDELINES, RECORDING CLINICAL EEG ON DIGITAL MEDIA REQUIRES MONITORS TO HAVE WHAT - BETWEEN 25 AND 35MM/SECOND HORIZONTAL SCALING AND A MINIMUM OF 100 DATA POINTS/SECOND TO ACCURATELY DISPLAY EEG ON THE MONITOR SCREEN IN A RECORD WITH 10HZ ALPHA ACTIVITY. WHEN THE DISPLAY EPOCH IS CHANGED FROM 10 SECONDS PER DISPLAY SCREEN TO 20 SECONDS PER DISPLAY SCREEN, THE FREQUENCY OF THE ACITIVTY WILL BE WHAT? - 10HZ GUIDELINES FOR RECORDING DIGITAL EEG ARE WRITTEN BY WHO? - THE AMERICAN CLINICAL NEUROPHYSIOLOGY SOCIETY (ACNS) THE TERM RAM MEANS WHAT - TEMPORARY MEMORY STORAGE THAT IS CRITICAL TO RAPID COMPUTER OPERATIONS THE ELECTRODE SITE THAT IS LOCATED 1CM ABOVE, ONE THIRD THE DISTANCE OUT FROM THE LEFT EXTERNAL AUDITORY MEATUS TOWARDS THE LEFT OUTER CANTHUS IS CALLED WHAT - T1 OR F9 3Katelyn Whitman, All Rights Reserved © 2025 Due to a central scalp lesion, C4 has to be relocated 4mm anteriorly. The technologist should: a. relocate C3 4mm anteriorly b. make no other placement changes c. relocate P3 4mm anteriorly d. relocate all electrodes in the right parasagittal plane 4mm anteriorly - A. RELOCATE C3 4MM ANTERIORLY IN A REFERENTIAL MONTAGE, HOW IS THE ORIGIN OF THE POTENTIAL DETERMINED? - AMPLITUDE WHEN RECORDING FOR ECI, INTERELECTRODE IMPEDANCES SHOULD BE AT LEAST____ OHMS, BUT LESS THAN _____ OHMS. - 100----10,000 WHEN RECORDING FOR ECI, IT IS RECOMMENDED THAT

Show more Read less
Institution
EEG
Course
EEG










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EEG
Course
EEG

Document information

Uploaded on
January 18, 2025
Number of pages
26
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EEG BOARD PREP 2025 QUESTIONS
AND ANSWERS 100% PASS

The EEG amplifier is designed so that when input 1 is more negative than input 2, the

deflection will be - ✔✔UPWARD


Common Mode Rejection - ✔✔the characteristic of an amplifier that rejects external

interference


WHICH OF THE FOLLOWING IS MOST ATTENUATED BY A LOW FREQUENCY

FILTER OF 1HZ - ✔✔0.1 HZ


TIME CONSTANT IS DEFINED AS THE TIME REQUIRED TO... - ✔✔FOR THE

DEFLECTION TO FALL (DECAY) TO 67% OF THE PEAK DEFLECTION


An EEG record has 3/sec spike & wave discharges. Both the spike and the slow wave

have voltages of 100uV. If this discharge is recorded with a LFF of 5Hz and a sensitivity

of 10uV/mm, what would be the deflection of the spike and the wave?


a. spike 10mm & wave 6mm


b. spike 6mm & wave 10mm


c. spike 10mm & wave 10mm



Katelyn Whitman, All Rights Reserved © 2025 1

,d. spike 6mm & wave 6mm - ✔✔SPIKE 10MM, WAVE 6MM


A HIGH FREQUENCY SETTING OF 35HZ WOULD ATTENUATE 50HZ MUSCLE

ACTIVITY BY APPROXIMATELY WHAT PERCENTAGE? - ✔✔40%


ACCORDING TO ACNS GUIDELINES, RECORDING CLINICAL EEG ON DIGITAL

MEDIA REQUIRES MONITORS TO HAVE WHAT - ✔✔BETWEEN 25 AND

35MM/SECOND HORIZONTAL SCALING AND A MINIMUM OF 100 DATA

POINTS/SECOND TO ACCURATELY DISPLAY EEG ON THE MONITOR SCREEN


IN A RECORD WITH 10HZ ALPHA ACTIVITY. WHEN THE DISPLAY EPOCH IS

CHANGED FROM 10 SECONDS PER DISPLAY SCREEN TO 20 SECONDS PER

DISPLAY SCREEN, THE FREQUENCY OF THE ACITIVTY WILL BE WHAT? -

✔✔10HZ


GUIDELINES FOR RECORDING DIGITAL EEG ARE WRITTEN BY WHO? - ✔✔THE

AMERICAN CLINICAL NEUROPHYSIOLOGY SOCIETY (ACNS)


THE TERM RAM MEANS WHAT - ✔✔TEMPORARY MEMORY STORAGE THAT IS

CRITICAL TO RAPID COMPUTER OPERATIONS


THE ELECTRODE SITE THAT IS LOCATED 1CM ABOVE, ONE THIRD THE

DISTANCE OUT FROM THE LEFT EXTERNAL AUDITORY MEATUS TOWARDS

THE LEFT OUTER CANTHUS IS CALLED WHAT - ✔✔T1 OR F9




Katelyn Whitman, All Rights Reserved © 2025 2

, Due to a central scalp lesion, C4 has to be relocated 4mm anteriorly. The technologist

should:


a. relocate C3 4mm anteriorly


b. make no other placement changes


c. relocate P3 4mm anteriorly


d. relocate all electrodes in the right parasagittal plane 4mm anteriorly - ✔✔A.

RELOCATE C3 4MM ANTERIORLY


IN A REFERENTIAL MONTAGE, HOW IS THE ORIGIN OF THE POTENTIAL

DETERMINED? - ✔✔AMPLITUDE


WHEN RECORDING FOR ECI, INTERELECTRODE IMPEDANCES SHOULD BE AT

LEAST____ OHMS, BUT LESS THAN _____ OHMS. - ✔✔100----10,000


WHEN RECORDING FOR ECI, IT IS RECOMMENDED THAT THE SENSITIVITY BE

_____ uV/MM AND THE LOW FILTER SHOULD NOT BE HIGHER THAN ____HZ.

FOR AT LEAST____MINS OF RECORDING. - ✔✔2uV, 1.0HZ, 30 MINS


THE TRACTS CONNECTING THE RIGHT AND LEFT HEMISPHERES ARE CALLED

WHAT? - ✔✔CORPUS CALLOSUM


THE CENTRAL SULCUS (FISSURE OF ROLANDO) DEMARCATES WHAT? -

✔✔FRONTAL AND PARIETAL LOBES




Katelyn Whitman, All Rights Reserved © 2025 3

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1094
Member since
2 year
Number of followers
482
Documents
33057
Last sold
22 hours ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

238 reviews

5
95
4
38
3
54
2
20
1
31

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions