Mass oil burner / NFPA 31 & NORA Exam Questions and Answers 100% Pass Cast iron fittings can be used in heating fuel systems? - False Tank vent shall terminate - Within 12 feet of the fill and visible from the fill Tanks exceeding 330 gallons must have - Top supply connection Fuel return piping from an appliance shall - Enter the top of the tank Oil appliances burning used oil shall only be installed - In commercial or industrial occupancies Technician must be present for filling of new oil tank - False A common tank vent pipe shall be - One pipe size larger than the largest individual vent pipe connected to it If oil supply piping is not visible for inspection you must - Pressure or vacuum test the line Installation instructions for the care and operation of the appliance must be posted - True Oil burning appliances shall have - Limit control for pressure in steam, temperature in water boiler, and temperature in furnace Above ground tank installed inside must be pitched - Torwards the supply at a pitch of 1/4 inch per foot Outdoor tanks must be located - Five feet from property line for 275g or smaller, ten feet for more than 275 but not exceeding 660g. Must be on concrete slab 2 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE A chimney connector shall maintain a pitch or rise of - 1/4 inch per foot Minimal gauge thickness for steel flue pipe connectors less than nine inches in diameter - 26 gauge Oil fired water heater must be equipped with water temp, pressure, and vacuum relief device - True Tank vent piping shall be - Pitched forward tank, terminate two feet minimum from building openings, corrosion resistant weatherproof cap Direct vent systems shall terminate - 4 feet horizontally from a building opening Fuel can be transferred from tank to appliance by pressurizing the tank - False Fusible link safety shutoff valves shall be located - Within six inches of the filter between the tank and filter Before installation of new oil burner you are required to - Inspect the combustion chamber A crankcase oil burner can be installed in any location where a standard oil burner was located - False Can tanks be installed in garages - Yes, if protected from vehicle impacts by barriers Teflon tape can be used on oil lines - False The trial for ignition period for oil burners less than 20 GPM is? - 15 seconds Fusible switches shall operate at a temp of - 165F A masonry chimney needs a metal liner - False Any valves used on oil burner installation must be a - Fusible valve What form is used to pull an oil burner permit - Form 1 What size pipe is used to cross connect tank outlet piping - 1/2 inch 3 | P a g e Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE What is an oil safety valve required - On existing installations when a burner, boiler, furnace or tank is replaced When must you install a draft regulator - When not exempted by the manufacturer As of January 1 2014, max safety timing for an oil burner safety switch must be no more than - 15 seconds What type of boiler must be equipped with low water cut off - Water boilers over 400,000 BTU, all steam boiler What device must be equipped with air proving switch - A draft inducer New burner controls must be - Interrupted ignition Hot water boilers need low water cut off if over - 500,000 BTU How far must continuous concrete slab extend beyond tank perimeter - 8 inches Can I use any form other than form 1 or form 1A - No, only form 1 and 1A are approved by state fire Marshall What must I do if I have a oil tank larger than 10,000 gallons - You must apply for, and obtain both a permit and license from the local town or city for the use of the tank What license are acceptable for installing an oil burner or oil tank - M.G.L c. 148, & 10D, and applicable provisions of St. 1964, C. 680 allows for only the holder of certific

Show more Read less
Institution
Oil Burners
Course
Oil Burners










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Oil Burners
Course
Oil Burners

Document information

Uploaded on
December 23, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

1|Page




Mass oil burner / NFPA 31 & NORA Exam
Questions and Answers 100% Pass

Cast iron fittings can be used in heating fuel systems? - ✔✔False


Tank vent shall terminate - ✔✔Within 12 feet of the fill and visible from the fill


Tanks exceeding 330 gallons must have - ✔✔Top supply connection


Fuel return piping from an appliance shall - ✔✔Enter the top of the tank


Oil appliances burning used oil shall only be installed - ✔✔In commercial or industrial occupancies


Technician must be present for filling of new oil tank - ✔✔False


A common tank vent pipe shall be - ✔✔One pipe size larger than the largest individual vent pipe

connected to it


If oil supply piping is not visible for inspection you must - ✔✔Pressure or vacuum test the line


Installation instructions for the care and operation of the appliance must be posted - ✔✔True


Oil burning appliances shall have - ✔✔Limit control for pressure in steam, temperature in water boiler,

and temperature in furnace


Above ground tank installed inside must be pitched - ✔✔Torwards the supply at a pitch of 1/4 inch per

foot


Outdoor tanks must be located - ✔✔Five feet from property line for 275g or smaller, ten feet for more

than 275 but not exceeding 660g. Must be on concrete slab




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

,2|Page


A chimney connector shall maintain a pitch or rise of - ✔✔1/4 inch per foot


Minimal gauge thickness for steel flue pipe connectors less than nine inches in diameter - ✔✔26 gauge


Oil fired water heater must be equipped with water temp, pressure, and vacuum relief device - ✔✔True


Tank vent piping shall be - ✔✔Pitched forward tank, terminate two feet minimum from building

openings, corrosion resistant weatherproof cap


Direct vent systems shall terminate - ✔✔4 feet horizontally from a building opening


Fuel can be transferred from tank to appliance by pressurizing the tank - ✔✔False


Fusible link safety shutoff valves shall be located - ✔✔Within six inches of the filter between the tank and

filter


Before installation of new oil burner you are required to - ✔✔Inspect the combustion chamber


A crankcase oil burner can be installed in any location where a standard oil burner was located - ✔✔False


Can tanks be installed in garages - ✔✔Yes, if protected from vehicle impacts by barriers


Teflon tape can be used on oil lines - ✔✔False


The trial for ignition period for oil burners less than 20 GPM is? - ✔✔15 seconds


Fusible switches shall operate at a temp of - ✔✔165F


A masonry chimney needs a metal liner - ✔✔False


Any valves used on oil burner installation must be a - ✔✔Fusible valve


What form is used to pull an oil burner permit - ✔✔Form 1


What size pipe is used to cross connect tank outlet piping - ✔✔1/2 inch




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

, 3|Page


What is an oil safety valve required - ✔✔On existing installations when a burner, boiler, furnace or tank

is replaced


When must you install a draft regulator - ✔✔When not exempted by the manufacturer


As of January 1 2014, max safety timing for an oil burner safety switch must be no more than - ✔✔15

seconds


What type of boiler must be equipped with low water cut off - ✔✔Water boilers over 400,000 BTU, all

steam boiler


What device must be equipped with air proving switch - ✔✔A draft inducer


New burner controls must be - ✔✔Interrupted ignition


Hot water boilers need low water cut off if over - ✔✔500,000 BTU


How far must continuous concrete slab extend beyond tank perimeter - ✔✔8 inches


Can I use any form other than form 1 or form 1A - ✔✔No, only form 1 and 1A are approved by state fire

Marshall


What must I do if I have a oil tank larger than 10,000 gallons - ✔✔You must apply for, and obtain both a

permit and license from the local town or city for the use of the tank


What license are acceptable for installing an oil burner or oil tank - ✔✔M.G.L c. 148, & 10D, and

applicable provisions of St. 1964, C. 680 allows for only the holder of certificate of competency to install

oil burner equipment and sign form 1A


Do I need to pull a permit when replacing an oil line or installing an osv - ✔✔Yes. Any alteration of oil

burner install requires a permit be pulled under CMR 1.00 using form 1 only




Created by Katelyn Whitman © 2025, All Rights Reserved. 100% PASS GUARANTEE

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
KatelynWhitman West Virginia University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1088
Member since
2 year
Number of followers
482
Documents
33020
Last sold
12 hours ago
Golden Quill Emporium Store

Get Yourself Well-Researched Study Materials to Ace Your Online& Actual Exam Tests with Confidence. STUDY LIKE A PRO WITH A WELL FORMATTED Q&A MATERIALS.

3.6

236 reviews

5
95
4
38
3
54
2
20
1
29

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions