Graded A +
Class 1 Product - ANSWER>>General Electronics Product - includes products where
the major requirement is function of the completed assembly.
Class 2 Product - ANSWER>>Dedicated Service Electronic Product - Continued
performance and extended life required. Uninterrupted service is desired but not
required.
Class 3 Product - ANSWER>>High Performance Electrical Product - Continued high
performance or performance-on-demand is critical. Equipment downtime cannot be
tolerated. Equipment might be used for life-support or other critical systems.
Who as the ultimate responsibility for identifying the class to which the assembly is
evaluated? - ANSWER>>The Customer.
Shall - ANSWER>>Invokes a requirement for manufacturers of all classes or product,
and failure to comply with the requirement is a noncompliance to this standard.
Order of Precedence in event of conflict 1 - ANSWER>>1. Procurement as agreed and
documented between customer and supplier.
Order of Precedence in event of conflict 2 - ANSWER>>Master drawing or master ass.
drawing reflecting the customer's detailed requirements.
Order of Precedence in event of conflict 3 - ANSWER>>IPC-1-610 when invoked by the
customer or contract.
, If documents other than IPC-A-610 are cited, the order of precedence shall be defined
in the _ - ANSWER>>Procurement documents
Target Condition - ANSWER>>A condition that is close to perfect, but is not always
achievable and may not be necessary to ensure the reliability of the assembly.
Acceptable Condition - ANSWER>>A condition that, while not necessarily perfect, will
maintain integrity and reliability of the assembly
Defect Condition - ANSWER>>The form, fit or function of the assembly is inadequate for
use in its end use environment.
A defect for Class 1... - ANSWER>>automatically implies a defect for Class 2 and 3. A
defect for Class 2 implies a defect for Class 3.
Disposition - ANSWER>>The determination of how defects should be treated. These
include rework, use as is, scrap, and repair.
Who dispositions defect conditions? - ANSWER>>The manufacturer, based on design,
service and customer requirements.
Process Indicator Conditions - ANSWER>>A condition (not a defect) that does not affect
the form, fit or function of a product.
Process indicators should be... - ANSWER>>monitored as part of the process control
system
Is disposition of individual process indicators required? - ANSWER>>No, and affected
products should be used as-is.