Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 39 pages
Exam (elaborations)

OIL BURNER LICENSE (MASSACHUSETTS) EXAM QUESTIONS AND CORRECT ANSWERSGRADE A+

Document preview thumbnail
Preview 4 out of 39 pages

OIL BURNER LICENSE (MASSACHUSETTS) EXAM QUESTIONS AND CORRECT ANSWERS GRADE A+

Content preview

HOSMERIT



OIL BURNER LICENSE


(MASSACHUSETTS) EXAM QUESTIONS AND
CORRECT ANSWERSGRADE A+


The fan limit control on a warm air unit is used to: - ✔✔✔Correct Answer > -Shut off the burner
at a predeterminedtemperature
-Start the blower at a predetermined temperature
-Stop the blower at a predetermined temperature


In all residential oil heating systems, the high limit control mustbe: - ✔✔✔ Correct Answer >
Line voltage and wired in series with the primary control


Low voltage thermostats are more widely used van line voltage thermostats because: - ✔✔✔
Correct Answer > They are moresensitive to ambient temperature



When a thermostat appears to be out of calibration, before recalibration it is important to first: -
✔✔✔ Correct Answer > -Be sure the thermostat is level
-Check to see that the hole behind the thermostat is sealed offproperly
-Be sure that the thermostat is acclimated to the roomtemperature




The primary control must be capable of: - ✔✔✔ CorrectAnswer > -Reacting to the absence
of flame
-Controlling the ignition and motor
-Locking out on safety in the event of flame failure

,When an interrupted ignition stack mounted primary is energized call - ✔✔✔ Correct Answer >
The motor and ignitionrelays pull in together



When using a remote mounted heat sensing primary control,the flame detector is often referred to
as: - ✔✔✔ Correct Answer > Pyrostat


Because of the cad cell eye's limited sensing range, it can only be used effectively to: - ✔✔✔
Correct Answer > Monitor an oilflame


It has been established that of steam is sufficient to operate any residential one-pipe steam
system. - ✔✔✔ Correct Answer > 2 psi




When installing a replacement steam boiler, it is important to: -✔✔✔ Correct Answer > Follow
the manufacturers pipinginstruction


In the early 1900's the was invented to prevent water from leaving the steam boiler should a return
line spring a leak.- ✔✔✔ Correct Answer > Hartford Loop

One of the reasons a radiator on a two pipe system fails to heatmay be: - ✔✔✔ Correct Answer
> A faulty thermostat trap

A steam pigtail should always be installed between the pressuretrol and the boiler to: - ✔✔✔
Correct Answer > Placea water seal between the boiler and the pressuretrol

In a one-pipe system, the minimum distance between the water level and the bottom of the
lowest steam carrying pipeis: - ✔✔✔ Correct Answer > 28 inches

To prevent scalding temperatures at the domestic water fixtures when using a tankless coil, it is
important to install a: -✔✔✔ Correct Answer > Tempering valve

A typical residential zone valve for a hot water heating systemnormally operates on: - ✔✔✔
Correct Answer > 24 volts

In most residential hot water heating systems, the design temperature difference between the
supply and return wateris: - ✔✔✔ Correct Answer > 20° F

,To properly size a zone circulator, you must know the following:- ✔✔✔ Correct Answer > The
gpm and feet of head of thepiping


The is used to prevent gravity circulation through the system when the boiler maintains
temperature. - ✔✔✔ CorrectAnswer > Flow control valve




Tribulations in the tubes of a fire tube boiler: - ✔✔✔ CorrectAnswer > Increase efficiency


In a forced warm air system, the return air duct size should never be less than of the supply
air duct size. - ✔✔✔Correct Answer > 80 percent


On a cold day, the burner is cycling on and off the flame is sufficient but the complaint of
insufficient heat may be caused by: - ✔✔✔ Correct Answer > Faulty or improperly set high
limit




Short cycling of the burner can be caused by: - ✔✔✔ CorrectAnswer > -The heat anticipator not
set properly
-High limit set too low
-Oversized equipment


The proper location for the vacuum gauge when testing a fuel unit and supply line is: - ✔✔✔
Correct Answer > A suction port

One reason oil would drop from the nozzle after the burner shuts down is: - ✔✔✔ Correct
Answer > A faulty fuel unit cut-off



On a burner that has been properly set up and adjusted, yet will experience an occasional hard
start or puff back, the problem may be: - ✔✔✔ Correct Answer > Low voltage input to the
transformer

, Off-cycle heat losses include: - ✔✔✔ Correct Answer > -Chimney draft
-Jacket loss


By replacing an old style burner with a new retention head burner, off-cycle losses are reduced
because: - ✔✔✔ CorrectAnswer > It restricts the draft induced airflow through the burner.


A simple, effective, yet inexpensive way to increase on-cycle system efficiency is to: - ✔✔✔
Correct Answer > Match thenozzle to the heating load


The are important for both on and off cycle efficiency ina fire tube boiler. - ✔✔✔ Correct
Answer > Combustion chambers




Before lowering the temperature of a hot water boiler, consideration must be given to the: - ✔✔✔
Correct Answer >Design of the heating system


The boiler or furnace is not the only source of heat loss. The heating system can lose heat
through: - ✔✔✔ Correct Answer >
-Uninsulated steam pipe
-Uninsulated hot water pipe
-Uninsulated warm air ducts



A condition often overlooked on a call involving odors is: -
✔✔✔ Correct Answer > Insufficient air in the boiler room

One method of removing oil and dirt from a newly installed steam boiler is to: - ✔✔✔ Correct
Answer > Skim the boilerthrough a nipple at the water level after a few days


If a cad cell is "seeing" light when the thermostat is connectedto the T-T terminals calls for heat:
- ✔✔✔ Correct Answer > The primary control will not energize

Document information

Uploaded on
November 27, 2024
Number of pages
39
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$15.19

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lectpearl
4.3
(6)
Sold
53
Followers
19
Items
1544
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions