S-12 CITYWIDE SPRINKLER SYSTEMSQuestionsand Verified Answers 100%CorrectGrade A Spring 2024/20251. THE IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINEQUALIFICATIONS. - answersOWNER 2. RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FORAMIN. OF__________ YEARS. - answers3 3. THE BUILDING OWNER SHALL ASSIGN A(N) TOCOMPLY WITHREQUIREMENTS. - answersIMPAIRMENT COORDINATOR 4. REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN FLOOR(S) ARE CONSIDERED PLANNED REMOVAL FROM SERVICE. - answers1 5. SHUTDOWNS AFFECTING MORE THAN FLOOR(S) ARE CONSIDEREDUNPLANNED OUT OF SERVICE CONDITIONS. - answers1 6. NOTIFICATIONTOFDNY IS NOT REQUIRED, PROVIDED SYSTEM IS RETURNED TOSERVICEWITHIN HOURS. - answers8 7. FOR UNPLANNED REMOVAL FROM SERVICE, THE COF HOLDER SHALL IMMEDIATELYREPORT CONDITION TO THE AND THE FIRE DEPT. - answersOWNEROFTHE BUILDING 8. IF A MINOR DEFECT IS OBSERVED, IT SHALL BE CORRECTED WITHIN DAYSORIT WILL BE CONSIDERED AN IMPAIRMENT. - answers30 9. WHAT DOES "OOS" STAND FOR? - answersOUTOF SERVICE ONLYSTUDENTS 2024/2025 ALL THE BEST ONLYSTUDENTS 2 10. OOS SYSTEMS SHALL BE IDENTIFIED BY PLACING AT FIRE DEPT. CONNECTIONS, SYS. CONTROL VALVES, AND FIRE COMMAND CENTER - answersTAGS 11. A SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL VALVE ANDANY SECTIONAL VALVES. - answersMASTER FIRE SUPPRESSION PIPING CONTRACTOR12. SHALL BE POSTED ON THE TAG INDICATING BOTH STATIC AND FLOWPRESSURES BEFORE AND AFTER. - answersDRAIN TEST RESULTS 13. GREEN TAGS INDICATE THAT . - answersNOIMPAIRMENT WAS FOUND14. GREEN TAGS WILL BE PLACED ON THE . - answersMAIN CONTROL VALVE15. SYSTEMS PARTIALLY OR FULLY OUT OF SERVICE SHALL HAVE A TAGPLACED ON THE MAIN CONTROL VALVE. - answersRED 16. A DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATETHESYSTEMIS FULLY OUT OF SERVICE. - answersWHITE 17. A DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATETHESYSTEM IS PARTIALLY OUT OF SERVICE. - answersBLUE 18. THE IMPAIRMENT COORDINATOR WILL NOTIFY THE CARRIER, CENTRAL STATION AND OCCUPANTS. - answersINSURANCE 19. PRIOR TO RETURNING A SYS. TO SERVICE, THE SHALL ENSURE THAT NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. - answersIMPAIRMENT COORDINATOR 20. GLYCERIN NOT GREATER THAN PERCENTOR GLYCOL NOT GREATHER THANPERCENT SHALL BE USED TO PROTECT FROM FREEZING. - answers50, 40 ONLYSTUDENTS 2024/2025 ALL THE BEST ONLYSTUDENTS 3 21. THE COF NUMBER AND SIGNATURE OF COF HOLDER SHALL BE POSTED NEAR THE . - answersMAIN CONTROL VALVE 22. SHALL BE READILY AVAILABLE TOANY REPRESENTATIVEOF THE FIRE DEPT. THESE ARE TO BE MAINTAINED ON SITE FOR 3 YEARS. - answersRECORDS 23. FAILURE TO MAKE INSPECTIONS MAY RESULT IN OF THE COF ANDCOURTPROCEEDINGS. - answersREVOCATION 24. THE COF HOLDER MAY INSPECT, TEST, AND PERFORM ROUTINE MX IF THEY HOLDTHEFOLLOWING CERTS: - answersREFRIGERATIONOPERATING ENGINEER,HIGHPRESSUREOPERATING ENGINEER, AND NYS HIGH PRESSURE OPERATING ENGINEER. 25. A CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE STANDPIPE ANDSPRINKLER SYSTEMS. - answersMASTER FIRE SUPPRESSION PIPINGCONTRACTOR(MFSPC) 26. A MASTER PLUMBER (MP) WITH COF IS LIMITED TORESIDENTIAL OCCUPANCIES WITHSPRINKLER HEADS OR LESS. - answers30 27. ABOUT PERCENT OF FIRES ARE EXTINGUISHED OR CONTROLLED WHENSPRINKLERS ARE INSTALLED. - answers96 28. WET PIPE SYSTEMS HAVE WATER AT A MINIMUM TEMP. OF TOPREVENT THESYSTEM FROM FREEZING. - answers40 FAHRENHEIT 29. VALVES ARE NOLONGER PERMITTED TOBE INSTALLED. - answersCOLDWEATHER 30. SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM CANNOT BE HEATEDTOPREVENT FREEZING. - answersDRY PIPE ONLYSTUDENTS 2024/2025 ALL THE BEST ONLYSTUDENTS 4 31. THE DROP IN CAUSES A SPECIAL DRY PIPE VALVE TO OPEN. - answersAIRPRESSURE 32. IN BUILDINGS WHERE LIFE HAZARD IS HIGH (SCHOOLS, HOSPITALS) THE ALARMIS TRANSMITTED DIRECTLY TO THE . - answersFIRE DEPARTMENT 33. DRY PIPE VALVES ARE OF A DESIGN. - answersCLAPPER

Content preview

ONLYSTUDENTS 2024/2025 ALL THE BEST




S-12 CITYWIDE SPRINKLER SYSTEMS Questions
and Verified Answers 100% Correct
Grade A Spring 2024/2025
1. THE IS RESPONSIBLE TO MAINTAIN SPRINKLER SYS. AND TO DETERMINE
QUALIFICATIONS. - answers>OWNER



2. RECORDS OF ALL INSPECTIONS AND MX SHALL BE MAINTAINED ON PREMISES FOR A
MIN. OF__________ YEARS. - answers>3



3. THE BUILDING OWNER SHALL ASSIGN A(N) TO COMPLY WITH
REQUIREMENTS. - answers>IMPAIRMENT COORDINATOR



4. REGULAR MX AND MINOR REPAIRS NOT AFFECTING MORE THAN FLOOR(S)
ARE CONSIDERED PLANNED REMOVAL FROM SERVICE. - answers>1



5. SHUTDOWNS AFFECTING MORE THAN FLOOR(S) ARE CONSIDERED
UNPLANNED OUT OF SERVICE CONDITIONS. - answers>1



6. NOTIFICATION TO FDNY IS NOT REQUIRED, PROVIDED SYSTEM IS RETURNED TO SERVICE
WITHIN HOURS. - answers>8



7. FOR UNPLANNED REMOVAL FROM SERVICE, THE COF HOLDER SHALL IMMEDIATELY
REPORT CONDITION TO THE AND THE FIRE DEPT. - answers>OWNER OF
THE BUILDING



8. IF A MINOR DEFECT IS OBSERVED, IT SHALL BE CORRECTED WITHIN DAYS OR
IT WILL BE CONSIDERED AN IMPAIRMENT. - answers>30



9. WHAT DOES "OOS" STAND FOR? - answers>OUT OF SERVICE




ONLYSTUDENTS 1

,ONLYSTUDENTS 2024/2025 ALL THE BEST



10. OOS SYSTEMS SHALL BE IDENTIFIED BY PLACING AT FIRE DEPT. CONNECTIONS,
SYS. CONTROL VALVES, AND FIRE COMMAND CENTER - answers>TAGS



11. A SHALL BE REQUIRED TO POST TAGS AT MAIN CONTROL VALVE AND ANY
SECTIONAL VALVES. - answers>MASTER FIRE SUPPRESSION PIPING CONTRACTOR



12. SHALL BE POSTED ON THE TAG INDICATING BOTH STATIC AND FLOW
PRESSURES BEFORE AND AFTER. - answers>DRAIN TEST RESULTS



13. GREEN TAGS INDICATE THAT . - answers>NO IMPAIRMENT WAS FOUND



14. GREEN TAGS WILL BE PLACED ON THE . - answers>MAIN CONTROL VALVE



15. SYSTEMS PARTIALLY OR FULLY OUT OF SERVICE SHALL HAVE A TAG
PLACED ON THE MAIN CONTROL VALVE. - answers>RED



16. A DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATE THE
SYSTEMIS FULLY OUT OF SERVICE. - answers>WHITE



17. A DISC OF 8-9 INCHES SHALL BE PLACED ON CONNECTIONS TO INDICATE THE
SYSTEM IS PARTIALLY OUT OF SERVICE. - answers>BLUE



18. THE IMPAIRMENT COORDINATOR WILL NOTIFY THE CARRIER, CENTRAL
STATION AND OCCUPANTS. - answers>INSURANCE



19. PRIOR TO RETURNING A SYS. TO SERVICE, THE SHALL ENSURE THAT
NECESSARY TESTS AND INSPECTIONS ARE CONDUCTED. - answers>IMPAIRMENT
COORDINATOR



20. GLYCERIN NOT GREATER THAN PERCENT OR GLYCOL NOT GREATHER THAN
PERCENT SHALL BE USED TO PROTECT FROM FREEZING. - answers>50, 40




ONLYSTUDENTS 2

, ONLYSTUDENTS 2024/2025 ALL THE BEST



21. THE COF NUMBER AND SIGNATURE OF COF HOLDER SHALL BE POSTED NEAR THE
. - answers>MAIN CONTROL VALVE



22. SHALL BE READILY AVAILABLE TO ANY REPRESENTATIVE OF THE FIRE DEPT.
THESE ARE TO BE MAINTAINED ON SITE FOR 3 YEARS. - answers>RECORDS



23. FAILURE TO MAKE INSPECTIONS MAY RESULT IN OF THE COF AND COURT
PROCEEDINGS. - answers>REVOCATION



24. THE COF HOLDER MAY INSPECT, TEST, AND PERFORM ROUTINE MX IF THEY HOLD THE
FOLLOWING CERTS: - answers>REFRIGERATION OPERATING ENGINEER, HIGH PRESSURE
OPERATING ENGINEER, AND NYS HIGH PRESSURE OPERATING ENGINEER.



25. A CAN INSPECT, MAINTAIN, TEST, AND REPAIR ALL FIRE STANDPIPE AND
SPRINKLER SYSTEMS. - answers>MASTER FIRE SUPPRESSION PIPING CONTRACTOR
(MFSPC)



26. A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL OCCUPANCIES WITH
SPRINKLER HEADS OR LESS. - answers>30



27. ABOUT PERCENT OF FIRES ARE EXTINGUISHED OR CONTROLLED WHEN
SPRINKLERS ARE INSTALLED. - answers>96



28. WET PIPE SYSTEMS HAVE WATER AT A MINIMUM TEMP. OF TO PREVENT THE
SYSTEM FROM FREEZING. - answers>40 FAHRENHEIT



29. VALVES ARE NO LONGER PERMITTED TO BE INSTALLED. - answers>COLD
WEATHER



30. SYSTEMS ARE INSTALLED WHERE A WET PIPE SYSTEM CANNOT BE HEATED TO
PREVENT FREEZING. - answers>DRY PIPE




ONLYSTUDENTS 3

Document information

Uploaded on
November 22, 2024
Number of pages
21
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Onlystudents
3.9
(19)
Sold
111
Followers
86
Items
1355
Last sold
2 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions