100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits

Rating
-
Sold
-
Pages
3
Grade
A+
Uploaded on
07-11-2024
Written in
2024/2025

Electrical Level 3 Module 1 Load Calculations and Branch Feeder Circuits

Institution
Electrical Level 3 Module 1 Load Calculations And
Course
Electrical Level 3 Module 1 Load Calculations and








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Electrical Level 3 Module 1 Load Calculations and
Course
Electrical Level 3 Module 1 Load Calculations and

Document information

Uploaded on
November 7, 2024
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ELECTRICAL LEVEL 3 MODULE 1 LOAD
CALCULATIONS AND BRANCH FEEDER
CIRCUITS COMPLETE DETAILED CASE
STUDY
kAccording to the NEC®, the ampacity of branch circuit conductors must be derated when there are
more than how many current-carrying conductors in a raceway? - 3



Air conditioning overcurrent protective devices can never exceed what percentage of the motor-rated
load current or the branch circuit selection current (whichever is greater)? - 225%



Conductors must be derated when installed in conduit - on or above rooftops



Continuous loads are calculated at what percentage of the maximum current rating of the overcurrent
device? - 80%



For a given load and length, the branch circuit voltage drop should not exceed - 3%



For resistance welders, the rating for the overcurrent protection device should not exceed what
percentage of the primary current rating of the welder? - 300%



Show window lighting is calculated at 200VA per linear foot plus - 125%



The allowable ampacity for eleven No. 12 THHN copper conductors in a cable must be adjusted by - 50%



The load for 10' of multi-outlet assembly used to supply several loads simultaneously is - 1,800VA



The maximum size dual-element fuse for a 40hp, 3Ø, 460V motor with a Design Letter D is - 100A

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
nursestuvate NURSING
View profile
Follow You need to be logged in order to follow users or courses
Sold
128
Member since
1 year
Number of followers
11
Documents
6772
Last sold
3 weeks ago
COMPLETE VICTORY

OUR MATERIALS REFLECT THE LATEST EXAM FORMATS & CONTENT WITH DETAILED EXPLANATION TO HELP YOU GRASP CHALLENGING CONCEPTS ... TEST YOUR KNOWLEDGE WITH OUR PRACTICE EXAMS DESIGNED TO SIMULATE THE REAL TEST EXPERIENCE ... I ASSURE GOOD GRADE IF YOU USE MY WORK...

3.5

15 reviews

5
7
4
1
3
2
2
2
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions