A suction line accumulator should be used in a residential heating pump only when recommended by the manufacturer if: a. Long refrigerant lines increase system charge over recommended maximum charge b. added oil dilution is required to maintain proper lubrication c. the system has low vapor line pressure drop and accumulator is added to improve efficiency d. the system does not include a high pressure switch or time delay - ANSWERA. Long refrigerant lines increase system charge over recommended maximum charge What three things happen when a heat pump is cycled into its defrost mode? a. reversing valve switches to the heating mode, and the outdoor fan is shut off and auxiliary heat is energized b. reversing valve switches to the cooling mode, crankcase heat is de-energized and auxiliary heat is energized c. reversing valves switches to the cooling mode, the outdoor fan is shut off and auxiliary heat is energized sing valves switches to the heating mode, the outdoor fan is shut off and auxiliary heat is de-energized - ANSWERc. reversing valves switches to the cooling mode, the outdoor fan is shut off and auxiliary heat is energized Which of the following is a benefit in using an electronic air cleaner?

Show more Read less
Institution
NATE P
Course
NATE P

Content preview

NATE Practice Exam CORRECT 100%
A suction line accumulator should be used in a residential heating pump only when recommended by
the manufacturer if:



a. Long refrigerant lines increase system charge over recommended maximum charge



b. added oil dilution is required to maintain proper lubrication



c. the system has low vapor line pressure drop and accumulator is added to improve efficiency



d. the system does not include a high pressure switch or time delay - ANSWERA. Long refrigerant
lines increase system charge over recommended maximum charge



What three things happen when a heat pump is cycled into its defrost mode?



a. reversing valve switches to the heating mode, and the outdoor fan is shut off and auxiliary heat is
energized



b. reversing valve switches to the cooling

mode, crankcase heat is de-energized and

auxiliary heat is energized



c. reversing valves switches to the cooling mode, the outdoor fan is shut off and auxiliary heat is
energized



d.reversing valves switches to the heating mode, the outdoor fan is shut off and auxiliary heat is de-
energized - ANSWERc. reversing valves switches to the cooling mode, the outdoor fan is shut off and
auxiliary heat is energized



Which of the following is a benefit in using an electronic air cleaner?



a. the ozone level is decreased

,b. all odors are removed



c. the air cleaner will not require cleaning



d. indoor air quality (IAQ) is improved - ANSWERd. indoor air quality (IAQ) is improved



A technician has the following conditions while checking a packaged heat pump in cooling.

*The unit has a piston type metering device on both the indoor and outdoor coils

*Outdoor temperature 75 degrees F

*Superheat 55 degrees F

What is the diagnosis and corrective action?



a. the unit is low on charge refrigerant needs to be added



b. the unit is operating properly and no further repair is needed



c. the unit is overcharged and charge needs to be recovered



d. there is a problem with airflow over the indoor coil and the filter needs to be changed or the
blower repaired - ANSWERa. the unit is low on charge refrigerant needs to be added



A Capacitor Start-Capacitor Run ( CSCR) motor has an open run capacitor. Will it start?



a. It may start, but it draws a higher than normal running current.



b. No, it would be unable to start without the run capacitor.



c. It can only start if the voltage is higher.



d. Yes, it will start, but it will run backwards. - ANSWERa. It may start, but it draws a higher than
normal running current.

,Why does the outdoor fan on a heat pump stop during defrost? - ANSWERa. minimize defrost time



b. decrease high side pressure



c. reduce compressor noise



d. increase defrost time



A heat pump operates normally in first stage heating. The first and second stage bulb appear to be
calling

compressor continues to run, but the auxiliary electric heat does not come on. Which of the
following

be included as a likely source of the problem?



a. the indoor blower is defective



b. the second stage heating circuit is open



c. the outdoor thermostat is closed



d. the thermostat anticipator is out of adjustment - ANSWERb. the second stage heating circuit is
open



What effect would insufficient voltage or current have on a solenoid valve?



a. the valve will remain half open



b. the valve will vibrate or chatter



c. it causes flash gas formation

, d. the valve will operate normally - ANSWERb. the valve will vibrate or chatter



Why is operating sound a consideration in the location of a condensing unit?



a. sound levels and system efficiency are closely related



b. excessive noise could be disruptive to the customer



c. condensing the unit sound is amplified by shrubbery



d. condensing sound is eliminated by shrubbery - ANSWERb. excessive noise could be disruptive to
the customer



With R-22 condensing pressure of 246 psig and a liquid line temperature of 108 degrees F what is the
sub-cooling?



a. 24 degrees F



b. 8 degrees F



c. 36 degrees F



d. 16 degrees F - ANSWERb. 8 degrees F



When using a double (dual) element time-delay fuse with a 20 amp motor, the maximum fuse size
should be:



a. 20 amps



b. 60 amps



c. 30 amps

Written for

Institution
NATE P
Course
NATE P

Document information

Uploaded on
November 6, 2024
Number of pages
36
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$14.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
NATE AC EXAM BUNDLE 2024!!
-
11 2024
$ 157.39 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ClassRep2 Strayer University
View profile
Follow You need to be logged in order to follow users or courses
Sold
68
Member since
3 year
Number of followers
46
Documents
2177
Last sold
5 days ago

2.1

7 reviews

5
1
4
1
3
0
2
1
1
4

Trending documents

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions