Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 12 pages
Exam (elaborations)

NICET FIRE ALARM LEVEL 1 LATEST EXAM WITH COMPLETE 50 QUESTIONS AND CORRECT SOLUTIONS

Document preview thumbnail
Preview 2 out of 12 pages

NICET FIRE ALARM LEVEL 1 LATEST EXAM WITH COMPLETE 50 QUESTIONS AND CORRECT SOLUTIONS

Content preview

NICET FIRE ALARM LEVEL 1 LATEST EXAM WITH
COMPLETE 50 QUESTIONS AND CORRECT
SOLUTIONS



QUESTION: At minimum, when working near power lines with voltage of 600 volts and lower,
an aerial lift operator shall maintain which distance from the lines? - 10 feet



QUESTION: The use of unprotected EMT shall be permitted under which conditions? - when in
direct contact with the earth



QUESTION: According to NFPA 70, what is the maximum unsupported length of 1/2-inch
flexible metallic conduit where flexibility is required after installation? - 4 1/2 feet



QUESTION: What is the maximum bend (in degrees) permitted in a conduit run between outlet
boxes? - 360 Degrees



QUESTION: If the primary power is disconnected and the fire alarm system goes into an alarm
condition, what is the minimum acceptable time for secondary power to operate the voice
evacuation systems? - 15 minutes



QUESTION: A riser room temperature switch should activate when the temperature falls below
which level? - 40 degrees F



QUESTION: According to NFPA 72, what is the maximum sound pressure level permitted in a
space with notification appliances? - 110 dBA

, QUESTION: What is the minimum interval for testing a single-station smoke detector in
multifamily units? - Annually



QUESTION: Where should a technician install a detector in relation to beam that is less than 12
inches deep and less that 8 feet in center? - At the bottom of the beam



QUESTON: When a device is inaccessible due to excessive height, such as an atrium, what it the
maximum interval for testing? - 18 months



QUESTION: When installing a wall-mounted fire telephone appliance to the public, what is the
acceptable maximum mounting height from the floor? - 66 inches



QUESTION: Elevator lobby smoke detectors shall be mounted within a maximum of which
distance from the center-line of the door? - 21 feet



QUESTION: An existing fire alarm cable in a drop ceiling will be spliced. which one of the
following splice locations will comply with NFPA 70? - secured inside a listed box or enclosure



QUESTION: Which function shall be tested for each newly installed smoke detector? - smoke
entry?



QUESTION: An 180 foot long corridor is 10 feet wide, with a smooth 10 foot ceiling,
interrupted by 4-inch beams spaced every 10 feet. How many heat detectors with a listed 30 foot
spacing are required? - 6 heat detectors



QUESTION: At which height must cables be physically protected when being installed within an
exposed ceiling? - 7 feet

Document information

Uploaded on
November 5, 2024
Number of pages
12
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$10.99

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Sold
2
Followers
0
Items
89
Last sold
11 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions