Inspection, testing, servicing, and other maintenance of sprinkler systems must be - ANSWERSpersonally supervised and be performed in accordance with NFPA (National Fire Protection Association) #25 2011 edition. Automatic and non-automatic sprinkler systems shall be inspected, tested and maintained as required by NFPA #25 2011 edition by - ANSWERScompetent person holding a S-12 Certificate of Fitness and employed or contracted by the owner How long must maintenance records be kept? - ANSWERSMinimum 3 years If there are 300 sprinkler heads or less how many spares must be kept on premises - ANSWERSAt least 6 How often do sprinkler connections need a hydrostatic pressure test? - ANSWERS5 years Who maintains the records of inspections, tests, servicing, and other items of maintenance? - ANSWERSImpairment coordinator Who assigns the impairment coordinator - ANSWERSBuilding owner Under what conditions should the fire department be notified regarding a system that is out of service? - ANSWERS- out of service on more than 1 floor of a building or - the repair cannot be completed in less than 8 hours or -there are one or more fire protection services out of order at the same time When the Cof holder observes a minor defect, he shall report the condition to the ____ ____ and if it is not corrected within ____ days it shall be deemed an ____ and reported in _____ to the ____ ____. - ANSWERSBuilding owner, 30, impairment, writing, FD

Show more Read less
Institution
S12 Sprinkler
Course
S12 Sprinkler










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
S12 Sprinkler
Course
S12 Sprinkler

Document information

Uploaded on
November 5, 2024
Number of pages
18
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

S12 Sprinkler Test 100% Verified!!

Inspection, testing, servicing, and other maintenance of sprinkler systems must be - ANSWERSpersonally
supervised and be performed in accordance with NFPA (National Fire Protection Association) #25 2011
edition.



Automatic and non-automatic sprinkler systems shall be inspected, tested and maintained as required by
NFPA #25 2011 edition by - ANSWERScompetent person holding a S-12 Certificate of Fitness and
employed or contracted by the owner



How long must maintenance records be kept? - ANSWERSMinimum 3 years



If there are 300 sprinkler heads or less how many spares must be kept on premises - ANSWERSAt least 6



How often do sprinkler connections need a hydrostatic pressure test? - ANSWERS5 years



Who maintains the records of inspections, tests, servicing, and other items of maintenance? -
ANSWERSImpairment coordinator



Who assigns the impairment coordinator - ANSWERSBuilding owner



Under what conditions should the fire department be notified regarding a system that is out of service? -
ANSWERS- out of service on more than 1 floor of a building or

- the repair cannot be completed in less than 8 hours or

-there are one or more fire protection services out of order at the same time



When the Cof holder observes a minor defect, he shall report the condition to the ____ ____ and if it is
not corrected within ____ days it shall be deemed an ____ and reported in _____ to the ____ ____. -
ANSWERSBuilding owner, 30, impairment, writing, FD

,Systems that are out of service, both planned and unplanned shall be identified by placing a tag on the
following locations: - ANSWERS- FD connections

- system control valves

- fire command center

- or clear visible location in lobby ofbuilding



Who is required to post tags at the main control valve? - ANSWERS- master fire suppression contractor
(class a or b)

-master plumber



Where would a green tag be placed? - ANSWERSMain control valve



If a system is fully out of service, what color and where should tags be placed? - ANSWERS- white disc on
all affected fire department connections

- red disc on main control valve



If a system is particularly out of service, what color and where should tags be placed? - ANSWERS-Blue
disc on all affected fire department connections

- red disc on main control valve



What should the red tag on the main control valve include? - ANSWERS- sprinkler company name

- date of removal from service

- anticipated working date



What should the tags indicate? - ANSWERS- area affected

- brief description of condition

-occupancy classification

- COF #

- est. time system will be operational

, What color are tags if no impairment is found? - ANSWERSGreen




Who are the ONLY people permitted to place a tag on a underground service main, water storage tank,
control valve, fire department connection, or booster pumps? - ANSWERSFDNY, owner, MFSPC or Master
plumber



Approved nonfreezing solutions include glycerin not greater than---- and glycon greater than ---- non
freezing solution - ANSWERS48%/38%



What is a riser card - ANSWERSAn approved card baring the dates of inspection, COF #, and signature of
COF holder.



Where should the riser card be placed? - ANSWERSOh the premesis near the main water supply control
valve




A MASTER PLUMBER (MP) WITH COF IS LIMITED TO RESIDENTIAL OCCUPANCIES WITH _________
SPRINKLER HEADS OR LESS. - ANSWERS30



Alarm Notification Appliance - ANSWERSA fire alarm system component, such as a bell, horn, speaker,
light, text display or vibration device that issues an audible, tactile, and/or visual alert



Alarm signal - ANSWERSA signal indicating an emergency requiring immediate action, such as a signal
indicative of fire.



Antifreeze Sprinkler System - ANSWERSA wet pipe sprinkler system employing automatic sprinklers that
are attached to a piping system that contains an antifreeze solution and is connected to a water supply.
The antifreeze solution is discharged, followed by water, immediately upon operation of sprinklers
opened by heat from a fire.



AUTOMATIC BALL DRIP DEVICES SHALL BE INSTALLED IN THE _________ POSITION. - ANSWERShorizontal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01 Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
277
Member since
2 year
Number of followers
106
Documents
14015
Last sold
1 day ago
PAPERSMASTER01

On this page you will find documents , package deals, flashcards offered by seller PAPERSMASTER01.With our documents on your side you"ll be well equipped to tackle you exams and achieve the grades you need.

3.9

71 reviews

5
22
4
33
3
9
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions