100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

ARDMS SPI STUDY GUIDE QUESTIONS & ANSWERS SCORED A+

Rating
-
Sold
-
Pages
16
Grade
A+
Uploaded on
29-10-2024
Written in
2024/2025

Spatial Pulse Length is directly proportional to - ️️the Number of Cycles in the Pulse and the Wavelength (Directly Proportional means that increased SPL will increase both the number of cycles in the pulse and the wavelength if increased). Spatial pulse length is inversely proportional to - ️️Frequency (MHz) (Inversely Proportional means that increased SPL will lower frequency. This is because axial resolution is better with lower frequency) In soft tissue, if the frequency of a wave is increased the Propagation Speed (PS) will... - ️️Remain the Same because stiffness and density affect Propagation Speed. What is the audible range? - ️️20-20,000Hz >20,000Hz=Ultrasound Frequency is measured in - ️️Hertz (Hz) is Cycles per Second Not affected by sonographer Increase Frequency; Decrease Depth A period is the length of time it takes for - ️️one complete wavelength to pass a fixed point PRP is determined by - ️️Transmit time and receive time. Period is measured in - ️️Time (μs) When the sonographer changes the imaging depth what parameters are changed? - ️️PRP, PRF, Duty Factor What is duty factor? - ️️The percentage or fraction of time that the system is transmitting a pulse (Time Sound is ON or ON-Time).Propagation Speed in SOFT TISSUE - ️️1.54 mm/μs (1540 m/sec) Unit of measurement for Pulse Duration, Duty Factor, PRP, and Period - ️️Time, (μs) Pulse duration is determined by - ️️Sound Source Only

Show more Read less
Institution
ARDMS SPI
Course
ARDMS SPI










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
ARDMS SPI
Course
ARDMS SPI

Document information

Uploaded on
October 29, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ARDMS SPI STUDY GUIDE
Spatial Pulse Length is directly proportional to - ✔️✔️the Number of Cycles in the
Pulse
and
the Wavelength

(Directly Proportional means that increased SPL will increase both the number of cycles
in the pulse and the wavelength if increased).


Spatial pulse length is inversely proportional to - ✔️✔️Frequency (MHz)

(Inversely Proportional means that increased SPL will lower frequency. This is because
axial resolution is better with lower frequency)

In soft tissue, if the frequency of a wave is increased the Propagation Speed (PS) will...
- ✔️✔️Remain the Same because stiffness and density affect Propagation Speed.

What is the audible range? - ✔️✔️20-20,000Hz

>20,000Hz=Ultrasound

Frequency is measured in - ✔️✔️Hertz (Hz)
is
Cycles per Second

Not affected by sonographer

Increase Frequency; Decrease Depth

A period is the length of time it takes for - ✔️✔️one complete wavelength to pass a
fixed point

PRP is determined by - ✔️✔️Transmit time and receive time.

Period is measured in - ✔️✔️Time (μs)

When the sonographer changes the imaging depth what parameters are changed? -
✔️✔️PRP, PRF, Duty Factor

What is duty factor? - ✔️✔️The percentage or fraction of time that the system is
transmitting a pulse (Time Sound is ON or ON-Time).

,Propagation Speed in SOFT TISSUE - ✔️✔️1.54 mm/μs
(1540 m/sec)

Unit of measurement for Pulse Duration, Duty Factor, PRP, and Period - ✔️✔️Time,
(μs)

Pulse duration is determined by - ✔️✔️Sound Source Only

Pulse Duration is controlled by - ✔️✔️the ultrasound system and transducer

Pulse Duration Formula - ✔️✔️pulse duration (μs) = # cycles in pulse/frequency(MHz)

PD= Number of cycles in Pulse/ Frequency(Hz)

Spatial Pulse Length (SPL) (measurement) - ✔️✔️The distance that a pulse occupies
in space from the start to the end of a pulse.
(mm)

Typical values for spatial pulse length in soft tissue. - ✔️✔️0.1 to 1.0 mm

Spatial pulse length is determined by - ✔️✔️sound source and medium


Pulse Duration (PD) - ✔️✔️The actual time from the start of a pulse to the end of that
pulse; a single transmit, talking, or "on" time.
Time the pulse is on typically measured in (ms).

Pulse Length - ✔️✔️The distance of the pulse start to end or the
duration or length of a single pulse
Pulse Length is typically measured in (mm).

the ability of an object to resist compression and relates to the hardness of a medium? -
✔️✔️Stiffness.

Think:
↑ Stiffness ↑ Speed
↓ Density ↑ Speed

An increase in pulse repetition frequency would lead to: - ✔️✔️Increasing pulse
repetition frequency, increases duty factor.

↑ PRF ↑ Duty Factor

, Which of the following would have the highest propagation speed? - ✔️✔️Bone has the
highest propagation speed, at 2000-4000 m/s.

What has the lowest propagation speed? - ✔️✔️air technically has the lowest
propagation speed at 300 m/s

Which has the Slowest Propagation Speed?
Water
Soft Tissue
Bone
Lung tissue - ✔️✔️Lung Tissue

As imaging depth increases, the pulse repetition frequency (PRF) must: -
✔️✔️Decrease

As imaging depth increase, pulse repeition freqency (PRF) decreases.

↑ Imaging Depth ↓ PRF

What describes the amount of refraction that occurs at an interface? - ✔️✔️Snell's law

Refraction: the redirection of the transmitted sound beam

Snell's law describes the angle of transmission at an interface based on the angle of
incidence and the propagation speeds of the two media.

Pressure is typically expressed in: - ✔️✔️Pascals (Pa)

The typical range of frequency for diagnostic ultrasound imaging is - ✔️✔️1-20 Mhz is
the typical range of frequency for diagnostic ultrasound imaging.

The attentuation coefficient in soft tissue is equal to: - ✔️✔️Attentuation Coeffcient =
1/2 (one half of the frequency in soft tissue)

The attentuation coeffcient (in dB/cm) is the rate at which sound is attentuated per unit
depth.

Micro is denoted as: - ✔️✔️Micro is denoted as millionth (µ)

What is described as the distance over which one cycle occurs? - ✔️✔️Wavelength is
distance over which one cycle occurs, or the distance from the beginning of one cycle to
the end of the same cycle.

Remember, it asks for distance over which one cycle occurs.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
PatrickKaylian Delaware State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
1806
Member since
2 year
Number of followers
1043
Documents
22113
Last sold
7 hours ago

3.8

316 reviews

5
147
4
60
3
54
2
15
1
40

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions