NICET Level I Exam/106
Questions and answers /A+
Scores
Fire Alarm Code? - -NFPA 72
-National Electric Code? - -NFPA 70
-AHJ? - -Authority Having Jurisdiction
-Disconnecting means for fire alarm power shall be what color? - -Red
-If a combination audible visible appliance is installed, the location of the
installed appliance shall be determined by the requirements of... - -The
visible appliance
-Two resistors are connected in parallel. Resister one measures 300 ohms
and resistor two measures 300 ohms. What is their equivalent resistance? - -
150 ohms
-Fire warning equipment to be installed in residential occupancies shall
produce the audible emergency evacuation signal described in... - -ANSI
S3.41
-The minimum number of restorable fixed temperature spot type heat
detectors that must be tested during each annual test is... - -Two detectors
or more on each initiating devices circuit
-What is the color code requirement for a spot type heat detector rated at
200°F? - -White
-Unless otherwise recommended by the manufacturer's published
instructions, single and multiple station smoke alarms installed in one and
two family dwellings shall be replaced every... - -10 years from the date of
manufacture
-When testing a water level supervisory switch serving a pressure tank, a
signal shall indicate if the water level has changed from the required level
by... - -Rising or falling 3 inches
-Fire alarm cables are permitted to be strapped to conduit to support the
cable. - -False
, -Where non-powered limited wiring is installed exposed, it must be
mechanically protected within how many feet of the finished floor? - -7 feet
-According to NFPA 72 visible notification appliances for non-sleeping areas
must be mounted between — and — inches above the finished floor? - -80 &
96
-If system impairment occurs, the owner must be notified — and within —? -
-In writing & 24 hours
-Conductors returning to the fire alarm control panel from the last field
device on the circuit might indicate what type of circuit? - -Class A
-Secondary power supplies for an EVAC fire alarm system shall be capable of
operating for a minimum of — of standby followed by — of alarm. - -24 hours
and 15 minutes
-The secondary power supply for protected premises shall automatically
provide power within how many seconds when the primary power fails? - -10
seconds
-When the temperature exceeds how many degrees Fahrenheit should spot
type smoke detectors not be installed? - -Above 100°F
-Who is responsible for maintaining personal protective equipment? - -The
employee
-What does GFCI stand for? - -Ground fault circuit interrupter
-After initial installation, a fixed temperature non-restorable spot type heat
detector shall be tested after how many years? - -15
-Heat detectors should be selected to operate at least how many degrees
Fahrenheit above the maximum expected ambient temperature at the
ceiling of the protected space? - -20°F
-According to NFPA 72, testing records of the fire alarm system shall be kept
until the next test and... - -Every one year after
-Who is responsible for storing and maintaining test records for the fire
alarm system? - -Owner of the system
-Household fire alarm system smoke detectors shall be tested by a
technician how regularly? - -Annually
Questions and answers /A+
Scores
Fire Alarm Code? - -NFPA 72
-National Electric Code? - -NFPA 70
-AHJ? - -Authority Having Jurisdiction
-Disconnecting means for fire alarm power shall be what color? - -Red
-If a combination audible visible appliance is installed, the location of the
installed appliance shall be determined by the requirements of... - -The
visible appliance
-Two resistors are connected in parallel. Resister one measures 300 ohms
and resistor two measures 300 ohms. What is their equivalent resistance? - -
150 ohms
-Fire warning equipment to be installed in residential occupancies shall
produce the audible emergency evacuation signal described in... - -ANSI
S3.41
-The minimum number of restorable fixed temperature spot type heat
detectors that must be tested during each annual test is... - -Two detectors
or more on each initiating devices circuit
-What is the color code requirement for a spot type heat detector rated at
200°F? - -White
-Unless otherwise recommended by the manufacturer's published
instructions, single and multiple station smoke alarms installed in one and
two family dwellings shall be replaced every... - -10 years from the date of
manufacture
-When testing a water level supervisory switch serving a pressure tank, a
signal shall indicate if the water level has changed from the required level
by... - -Rising or falling 3 inches
-Fire alarm cables are permitted to be strapped to conduit to support the
cable. - -False
, -Where non-powered limited wiring is installed exposed, it must be
mechanically protected within how many feet of the finished floor? - -7 feet
-According to NFPA 72 visible notification appliances for non-sleeping areas
must be mounted between — and — inches above the finished floor? - -80 &
96
-If system impairment occurs, the owner must be notified — and within —? -
-In writing & 24 hours
-Conductors returning to the fire alarm control panel from the last field
device on the circuit might indicate what type of circuit? - -Class A
-Secondary power supplies for an EVAC fire alarm system shall be capable of
operating for a minimum of — of standby followed by — of alarm. - -24 hours
and 15 minutes
-The secondary power supply for protected premises shall automatically
provide power within how many seconds when the primary power fails? - -10
seconds
-When the temperature exceeds how many degrees Fahrenheit should spot
type smoke detectors not be installed? - -Above 100°F
-Who is responsible for maintaining personal protective equipment? - -The
employee
-What does GFCI stand for? - -Ground fault circuit interrupter
-After initial installation, a fixed temperature non-restorable spot type heat
detector shall be tested after how many years? - -15
-Heat detectors should be selected to operate at least how many degrees
Fahrenheit above the maximum expected ambient temperature at the
ceiling of the protected space? - -20°F
-According to NFPA 72, testing records of the fire alarm system shall be kept
until the next test and... - -Every one year after
-Who is responsible for storing and maintaining test records for the fire
alarm system? - -Owner of the system
-Household fire alarm system smoke detectors shall be tested by a
technician how regularly? - -Annually