A phase converter with a 56 ampere full-load single phase input nameplate rating, that supplies variable loads shall have an input conductor ampacity of __ amperes. Phase Converters 455.6(A)(1) - ANSWER70 The grounded conductor of a 277/480 volt 3 phase wye service shall be run to and bonded to each ____ AC systems, grounding connections 250.24(C) - ANSWERservice disconnecting means Parralleled, ungrounded 480 volt 3 phase 3 wire delta service conductors shall contain parallel equipment bonding jumpers based on the size of the ____ in each raceway. Jumpers, bonding, Service equipment 250.102(C)(2) - ANSWERservice entrance conductors Luminaires that use a metal halide lamp other than a PAR lamp shall be provided with: Ballasts, electric discharge lamps, Protection in recessed HID fixtures 410.130(F)(5) - ANSWERa containment barrier that encloses the lamp The maximum standard overcurrent device rating for 3 parallel runs of 75 degrees C rated, 350 kcmil THHW copper conductors in three parallel runs of EMT is _ amperes. Ampacity tables Table 310.15(B)(16), 240.4(C), 240.6 - ANSWER800 Liquidtight flexible metal conduit with listed fittings shall be permitted in:

Show more Read less
Institution
Journeyman Wireman Electrical
Course
Journeyman Wireman Electrical









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Journeyman Wireman Electrical
Course
Journeyman Wireman Electrical

Document information

Uploaded on
October 18, 2024
Number of pages
5
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Journeyman Wireman Electrical Test
Study Guide NEC - Larry Bobo
Workbook Exam 100% Correct!!

A phase converter with a 56 ampere full-load single phase input nameplate rating, that supplies
variable loads shall have an input conductor ampacity of __ amperes.



Phase Converters

455.6(A)(1) - ANSWER70



The grounded conductor of a 277/480 volt 3 phase wye service shall be run to and bonded to each
____



AC systems, grounding connections

250.24(C) - ANSWERservice disconnecting means



Parralleled, ungrounded 480 volt 3 phase 3 wire delta service conductors shall contain parallel
equipment bonding jumpers based on the size of the ____ in each raceway.

Jumpers, bonding, Service equipment

250.102(C)(2) - ANSWERservice entrance conductors



Luminaires that use a metal halide lamp other than a PAR lamp shall be provided with:



Ballasts, electric discharge lamps, Protection in recessed HID fixtures

410.130(F)(5) - ANSWERa containment barrier that encloses the lamp



The maximum standard overcurrent device rating for 3 parallel runs of 75 degrees C rated, 350 kcmil
THHW copper conductors in three parallel runs of EMT is _ amperes.

Ampacity tables

Table 310.15(B)(16), 240.4(C), 240.6 - ANSWER800

, Liquidtight flexible metal conduit with listed fittings shall be permitted in:

Class I Locations,

501.10(B)(2)(4), 501.30(B)(2) - ANSWERClass 1, Division 1 locations in lengths less than 6 ft with an
equipment bonding jumper



At an outdoor motor fuel dispensing facility, the area up to 18 inches above grade and within 20 feet
from the edge of a LPG dispenser shall be classified as:



Motor fuel dispensing facilities, Class I locations, Table 514.3(B)(1), Electrical equipment classified
areas,

514.3(B)(2), Table 514(B)(2) - ANSWERClass 1, Division 2



In other spaces used for envirnmental air handling purposes other than ducts or plenums, such as
the space above a suspended ceiling, which of the wiring methods is NOT allowed?



Cable trays, Plenums

300.22(C)(1) - ANSWERLiquidtight Flexible Metal Conduit




In non-residential use, what is the maximum overcurrent protection ampere rating for 2 AWG RHW
aluminum conductors with an ambient temperature of 88 degrees F?



Ampacity Tables

Table 310.15(B)(16) - ANSWER90



Panelboards shall have overcurrent protection of 200 amperes or less where equipped with snap
switches rated at _ amperes or less.



AC-DC general use snap switches, Panelboards, use in OR Switches, Panelboards, use in

408.36(A) - ANSWER30



If no overcurrent protection is provided on the secondary of a 480-volt, 3 phase, 5KVA transformer,
what is the maximum ampere primary overcurrent protection allowed?

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01 Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
277
Member since
2 year
Number of followers
106
Documents
14036
Last sold
5 hours ago
PAPERSMASTER01

On this page you will find documents , package deals, flashcards offered by seller PAPERSMASTER01.With our documents on your side you"ll be well equipped to tackle you exams and achieve the grades you need.

3.9

71 reviews

5
22
4
33
3
9
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions