Where conduits enter a floor-standing switchboard or panelboard at the bottom, the conduits including their end fittings, shall not rise more than _____ above the bottom of the enclosure. a) 6 inches b) 4 inches c) 2 inches d) 3 inches - ANSWERD: 3 inches Ref: 408.5 When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be connected _____. a)on the line side of the service disconnect overcurrent device b) on the load side of the service disconnect overcurrent device c) on the meter housing d) at the final overcurrent device - ANSWERB: on the load side of the service disconnect overcurrent device Ref: 285.24(A) A detached garage supplied from a dwelling with a three-wire feeder of size 4/0 AWG aluminum USE cable with a 200-ampere rated circuit breaker for overcurrent protection requires a MINIMUM size copper grounding electrode to a concrete encased electrode of _____ AWG. a) 8 b) 6 c) 4 d) 2 - ANSWERC: 4

Show more Read less
Institution
Journeyman Electrician
Course
Journeyman Electrician









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Journeyman Electrician
Course
Journeyman Electrician

Document information

Uploaded on
October 18, 2024
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Journeyman Electrician #4 Exam 100%
Correct!!

Where conduits enter a floor-standing switchboard or panelboard at the bottom, the conduits
including their end fittings, shall not rise more than _____ above the bottom of the enclosure.



a) 6 inches

b) 4 inches

c) 2 inches

d) 3 inches - ANSWERD: 3 inches

Ref: 408.5



When installed on the service of a building or structure, a type 2 SPD (TVSS) shall be connected
_____.



a)on the line side of the service disconnect overcurrent device

b) on the load side of the service disconnect overcurrent device

c) on the meter housing

d) at the final overcurrent device - ANSWERB: on the load side of the service disconnect overcurrent
device

Ref: 285.24(A)



A detached garage supplied from a dwelling with a three-wire feeder of size 4/0 AWG aluminum USE
cable with a 200-ampere rated circuit breaker for overcurrent protection requires a MINIMUM size
copper grounding electrode to a concrete encased electrode of _____ AWG.



a) 8

b) 6

c) 4

d) 2 - ANSWERC: 4

Ref: 250.52(A)(3)

, When a raceway is run from the interior to the exterior of a building, the raceway shall _____.



a) be rigid metal conduit (RMC)

b) be rigid polyvinyl chloride conduit (PVC)

c) be sealed with an approved material

d) have an explosion-proof seal - ANSWERC: be sealed with an approved material

Ref: 300.7(A)



A disconnecting means shall be provided on the supply side of all fuses in circuits having a voltage of
at LEAST _____ volts to ground.



a) 120

b) 250

c) 150

d) 277 - ANSWERC: 150

Ref: 240.40



Ref: 501.15(A)(1)



Surface-mounted incandescent luminaires installed on the wall above the door or on the ceiling of a
clothes closet shall have a clearance of at LEAST ____ between the luminaire and the nearest point
of storage.



a) 6 inches

b) 8 inches

c) 18 inches

d) 12 inches - ANSWERD: 12 inches

Ref: 410.16(C)(1)



The NEC considers the area around the fuel dispensing pumps at a service station to be a hazardous
location. This area extends a height of 18 inches above grade, and up to a distance from the
enclosure of the dispensing pump of _____.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01 Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
277
Member since
2 year
Number of followers
106
Documents
14036
Last sold
5 hours ago
PAPERSMASTER01

On this page you will find documents , package deals, flashcards offered by seller PAPERSMASTER01.With our documents on your side you"ll be well equipped to tackle you exams and achieve the grades you need.

3.9

71 reviews

5
22
4
33
3
9
2
3
1
4

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions