A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. a. Light b. Medium c. Heavy d. Extra Heavy - ANSWERc. Heavy From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in subsection (3), and individual other than an individual who is licensed under this article and ______________ working under the direction of a holder of an electrical contractors licence, shall not in any manner undertake to execute any electrical work". - ANSWER...And employed by and... A box with (2) 14/3 NM, one yoke, and a clamp requires a minimum or _____ cubic inches. a. 16 b. 18 c. 20 d. 22 - ANSWERc. 20 NM Cable in a 2x4x2.5 plastic box will not require a cable clamp if secured within _____ inches of the box. a. 8 b. 12 c. 16 d. 20 - ANSWERa. 8 A box with #10 AWG THHN will require a free space of _____inches. a. 2 b. 2.25 c. 2.5 d. 3 - ANSWERc. 2.5 (See Table 314.16 (B).) A mobile home with 100 amp service will require service conductors of ____ AWG.

Show more Read less
Institution
Electrical Journeyman
Course
Electrical Journeyman

Content preview

Electrical Journeyman Test 2024
Questions & Answers 100% Correct!!

A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty.

a. Light

b. Medium

c. Heavy

d. Extra Heavy - ANSWERc. Heavy



From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in subsection
(3), and individual other than an individual who is licensed under this article and ______________
working under the direction of a holder of an electrical contractors licence, shall not in any manner
undertake to execute any electrical work". - ANSWER...And employed by and...



A box with (2) 14/3 NM, one yoke, and a clamp requires a minimum or _____ cubic inches.

a. 16

b. 18

c. 20

d. 22 - ANSWERc. 20



NM Cable in a 2x4x2.5 plastic box will not require a cable clamp if secured within _____ inches of the
box.

a. 8

b. 12

c. 16

d. 20 - ANSWERa. 8



A box with #10 AWG THHN will require a free space of _____inches.

a. 2

b. 2.25

c. 2.5

,d. 3 - ANSWERc. 2.5 (See Table 314.16 (B).)



A mobile home with 100 amp service will require service conductors of ____ AWG.

a. #4

b. #3

c. #2

d. #1 - ANSWERa. #4 (See 550.33 (B) and 310.15 (B)(7).)



Permanently installed pool motors shall have a cord length of_____

a. 3ft

b. 6ft

c. 12ft

d. 20ft - ANSWERa. 3ft (See 680.21 (A)(3).)



The conductor feeding a wet-niche pool light will be _____

a. Electrical Metallic Conduit

b. Rigid conduit made of brass

c. Flexible metallic conduit

d. Something else..... - ANSWERb. Rigid conduit made of brass (See 680.23(B)(2) and (B)(2)(a).)



Which conductor is not allowed to be used as a service conductor?

a. USE

b. MC Cable

c. Underground Feeder

d. MI Cable - ANSWERc. Underground Feeder (See 338.12 (B)



What is the % conduit fill used in a nipple that does not exceed 24" - ANSWERA: 60% (see chapter 9
table 1 note (4).)



Car Wash Receptacle must be - ANSWERWR Weather Resistant (see 406.9 (B)(1).)

, Overhead Service conductor clearance for pedestrian walkway - ANSWER10' (see 230.24 (B)(1).)



Snap switch used for motor must not exceed - ANSWER80% of the amp rating of the switch (see
404.14 (A)(3).)



Max amperage of Edison based fuse - ANSWER30A (see 240.51 (A).)



What can you put on a small appliance circuit. - ANSWERReceptacles for a gas fired range, oven, or
countertop cooking unit (see 210.52 (B)(2) Exception 2)



Type of branch circuit needed for a furnace or other central heating equipment - ANSWERIndividual
Branch Circuit (see 422.12)

A service with (4) 4" PVC conduits with (4) 800KCMIL feeder in each will require a main bonding
jumper of what AWG?

a. 4/0

b. 1/0

c. 250 KCMIL

d. 500 KCMIL - ANSWERd. 500 KCMIL (See Table 250.102 (C)(1) and Chapter 9 Table 8



A conduit protecting the grounding electrode conductor shall be bonded to the ____ at both ends. -
ANSWERGrounding Electrode Conductor (See 250.66(E)(1).)



A grounding electrode encased in concrete shall be _____ft long and _____ in circumference.

a. 8ft, 5/8"

b. 12ft, 1⁄2"

c. 20ft, 1⁄2"

d. Something else... - ANSWERc. 20ft, 1⁄2" (See 250.52(A)(3).)



The required outlet for an in-ground pool shall be mounted _____

a. On the wall of a building 21 feet from waters edge

b. On a balcony 8 feet above water level

c. On a support 3 feet from waters edge

d. On a post 6'6" above grade level - ANSWERd. On a post 6'6" above grade level (See 680.22(A)(1).)

Written for

Institution
Electrical Journeyman
Course
Electrical Journeyman

Document information

Uploaded on
October 18, 2024
Number of pages
17
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$15.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
JOURNEYMAN ELECTRICIAN EXAM BUNDLE(FULL PACK)QUESTIONS & ANSWERS 100% ACCURATE
-
1 24 2024
$ 40.99 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
papersmaster01 Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
301
Member since
2 year
Number of followers
106
Documents
14704
Last sold
1 month ago
PAPERSMASTER01

On this page you will find documents , package deals, flashcards offered by seller PAPERSMASTER01.With our documents on your side you"ll be well equipped to tackle you exams and achieve the grades you need.

3.9

73 reviews

5
22
4
34
3
10
2
3
1
4

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions