Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Texas Irrigation Technician Exam question and answers

Rating
-
Sold
-
Pages
6
Grade
A+
Uploaded on
17-10-2024
Written in
2024/2025

Texas Irrigation Technician Exam question and answers Backflow preventionA mechanical means to prevent a backflow A backflow deviceAny approved device that prevents an undesireable reversal of flow of water 1 column foot of water.443 psi (pretty close to 5 ft. 1 psirequires a column of water 2.31 feet tall (or 3 ft.) (or 27.75 in.) max flowrate for 1/2 in pipe (to stay below 5 fps)5 gpm max flowrate for 3/4 in pipe (to stay below 5 fps)10 gpm max flowrate for 1 in pipe (to stay below 5 fps)15 gpm max flowrate 1 1/4 in. pipe (to stay below 5 fps)25 gpm max flowrate for 1 1/2 in pipe (to stay below 5 fps)35 gpm Key requirement for RPZ backflowminimum of 12" above grade Key requirement for Double Check backflow (DCVA)If installed below grade, Test cocks must be plugged with non-ferrous (non-magnetic) material Key requirements for PVB and SVBMust be 12" above highest head, valve, pipe, fitting, or fixture Key requirements for Air GapThe recieving pipe must be 1" wider or 2 times

Show more Read less
Institution
Texas Irrigation
Course
Texas Irrigation

Content preview

Texas Irrigation Technician Exam
question and answers
Backflow prevention✔✔A mechanical means to prevent a backflow

A backflow device✔✔Any approved device that prevents an undesireable reversal of
flow of water

1 column foot of water✔✔.443 psi (pretty close to 5 ft.

1 psi✔✔requires a column of water 2.31 feet tall (or 3 ft.) (or 27.75 in.)

max flowrate for 1/2 in pipe (to stay below 5 fps)✔✔5 gpm

max flowrate for 3/4 in pipe (to stay below 5 fps)✔✔10 gpm

max flowrate for 1 in pipe (to stay below 5 fps)✔✔15 gpm

max flowrate 1 1/4 in. pipe (to stay below 5 fps)✔✔25 gpm

max flowrate for 1 1/2 in pipe (to stay below 5 fps)✔✔35 gpm

Key requirement for RPZ backflow✔✔minimum of 12" above grade

Key requirement for Double Check backflow (DCVA)✔✔If installed below grade, Test
cocks must be plugged with non-ferrous (non-magnetic) material

Key requirements for PVB and SVB✔✔Must be 12" above highest head, valve, pipe,
fitting, or fixture

Key requirements for Air Gap✔✔The recieving pipe must be 1" wider or 2 times
bigger than the discharge pipe

zone flow✔✔how many gallons go through a zone

Backflow Prevention Assembly✔✔Any assembly used to prevent backflow into a
potable water system. The type of assembly used is based on the existing or
potential degree of health hazard and backflow condition.

booster pump✔✔increases operating pressure

Bushing✔✔The method of adapting a fitting to either a larger or smaller size.

, Check Valve✔✔A valve that allows flow in one direction but Who composes the
Irrigator Council?✔✔6 Irrigators, 3 Public members, all from the same state

What is the purpose of the Irrigator Council?✔✔Provide advice on matters
concerning irrigation

Possible consequence of installing a system w/o a license?✔✔Being charged with a
Class C misdemeanor

Absorption Rate✔✔How fast a rate at which the soil will accept water

Actual Head Pressure✔✔The operating pressure measured at the base of a
sprinkler head

How to CALCULATE Actual head pressure?✔✔subtract all pressure losses from
static pressure

air gap✔✔A complete physical separation between the free flowing discharge end of
a potable water supply pipeline and an open or non-pressure recieveing vessel

Application Rate✔✔Rate that a head applies water to the area it's spraying

What term is Application rate synonymous with?✔✔Precipitation Rate

Arc✔✔The surface area of the landscape that the head will provide water (half, full,
90, 25)

as-built plans✔✔A corrected or redrawn plan, showing location of all major
components of a system

A.W.W.A.✔✔American Water Works Association

Backflow✔✔The UNDESIREABLE reverse flow of water in a piping system

Back pressure✔✔Condition that can happen due to elevation pumps, pressure

Back siphonage✔✔backflow due to a sub atomic pressure (break in city main, fire
hydrant being used

prevents flow in the opposite direction.

Completion of irrigation system✔✔All standards are met and the irrigator is satisfied

Class Pipe✔✔Class = How many pounds of pressure it can withstand before the
pipe bursts

Written for

Institution
Texas Irrigation
Course
Texas Irrigation

Document information

Uploaded on
October 17, 2024
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$8.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
ExamZen

Get to know the seller

Seller avatar
ExamZen Liberty University
View profile
Follow You need to be logged in order to follow users or courses
Sold
16
Member since
1 year
Number of followers
3
Documents
539
Last sold
1 month ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions