California Fluoroscopy Test Questions
and Answers- 100% pass
An image intensifiers photocathode causes ___ to be given off in direct proportion to the
intensity of the fluorescent light:
a. remnant radiation
b. electrons
c. x-rays
d. light photons - Answer✔✔-electrons
What fluoroscopic television system device decodes the video signal into a visible image?
a. Vidicon camera
b. Camera control unit
c. Television monitor
d. Electron gun - Answer✔✔-Television Monitor
Which of the following materials are used in the construction of a fluoroscopic tabletop?
1. Lead
2. Aluminum
Page 1/107
,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024
3. Bakelite
4. Carbon fiber - Answer✔✔-2, 3, and 4
Geometric factors in the shape of the image intensification tube
b. Focal-film-distance (FFD)
c. Object-to-image distance (OID)
d. Minification gain - Answer✔✔-...
If the entrance skin dose is measured from the surface of the tabletop, the x-ray source is
located:
a. either over or under the table
b. under the table
c. over the table
d. not enough information provided - Answer✔✔-b. Under the table
The mottle level of an image can be adjusted by:
1. changing mA
2. changing kVp
3. changing the exposure factors
4. increasing the number of available x-ray photons - Answer✔✔-All of the above
Page 2/107
,EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024
During a fluoroscopic exam, the main source of scattered radiation is produced from:
a. the patient
b. x-ray source
c. table top
d. leakage radiation - Answer✔✔-the patient
Excessive lighting in the fluoroscopy room:
a. Helps to perceive a dim image as brighter
b. Helps to properly adjust the overall luminance of the TV image
c. Enhances visualization of a black and white TV image
d. May result in increasing the technical operating factors - Answer✔✔-May result in increasing
the technical operating factors
Suitable gonad shields must be used:
a. Whenever gonads are within the useful x-raybeam
b. When shielding of gonads does not interfere with the diagnosis
c. On all potentially procreative patients
d. At all times - Answer✔✔-When shielding of gonads does not interfere with the diagnosis
Which of the following are true concerning cine film?
Page 3/107
, EMILLECT 2024/2025 ACADEMIC YEAR ©2024 EMILLECT. ALL RIGHTS RESERVED FIRST PUBLISH OCTOBER, 2024
1. Available film sizes are: 70 mm, 100 mm, and 110 mm
2. The larger the film size the better the image quality
3. Nearly all cine-fluorography exams involve studies of the GI system
4. Delivers approximately the same dose as routine photospot image recording - Answer✔✔-2
only
The exposure rate at the tabletop may not exceed five rads per minute except:
1. when using the ABC on large patients
2. during magnification mode
3. where higher exposure rates are allowed - Answer✔✔-b. 1, 2 and 3 only
Images produced with photo spot film cameras ___ spot films taken with conventional
cassettes.
1. use a higher mA than
2. require about 1/2 to 1/3 the dose of
3. exhibit superior image quality compared to - Answer✔✔-require about 1/2 to 1/3 the dose
The ability of an imaging system to differentiate small objects that are closely spaced as
separate objects is referred to as:
a. Differentiation
b. Resolution
Page 4/107