Nicet level 1 Study Guide questions with correct answers When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level (NFPA 72, Table 14.4.3.2 17 (j) (4) - Answer-rises or falls over 3 inches If combination audible/visible appliances are installed the location of the installed appliance shall be determined by the requirements of _______. (Nfpa 72 18.4.8.1) - Answer-the visible appliance What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT? (Nec Annex C tables) - Answer-26 Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their equivalent resistance? - Answer-150 ohms A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat detector has been selected that is listed for a 50' maximum spacing between detectors. According to NFPA 72 how many detectors will be needed to protect this room? EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED FIRST PUBLISH SEPTEMBER 2024 Page 2/20 200 / 50 x 150 / 50 = - Answer-12 According to NFPA 72 the minimum number of restorable fixed temperature spot type heat detectors that must be tested during each annual test is? (NFPA 72 14.4.4.5.1) - Answer-Two detectors or more on each initiating device circuit According to NFPA 72 how many spot type heat detectors are required for a space that is 80' long and 55 floor wide with a smooth 10' ceiling? the detector is listed for a maximum space between detectors of 30' - Answer-6 What color code requirement for a spot type heat detector rated at 200゚F - Answer-White (NFPA 72, Table 17.6.2.1) Unless otherwise recommended by the manufacturers published instructions single and multiple stations smoke alarms installed in one and 2 family dwellings shall be replaced every - Answer-10 years from the day-of manufacture. (NFPA 72, 14.4.7.1) Fire alarm cables are permitted to be strapped to conduit to su

Show more Read less
Institution
Nicet
Course
Nicet










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Nicet
Course
Nicet

Document information

Uploaded on
October 6, 2024
Number of pages
20
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024




Nicet level 1 Study Guide questions with
correct answers

When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water

level _____________from the required level




(NFPA 72, Table 14.4.3.2 17 (j) (4) - Answer✔✔-rises or falls over 3 inches


If combination audible/visible appliances are installed the location of the installed appliance shall be

determined by the requirements of _______.




(Nfpa 72 18.4.8.1) - Answer✔✔-the visible appliance


What is the maximum number of 12 gauge THHN wires that can be installed in 1" EMT?




(Nec Annex C tables) - Answer✔✔-26


Two resistors are connected in parallel. R1 = 300 Ohms, R2 = 300 Ohms. What is their equivalent

resistance? - Answer✔✔-150 ohms


A Room is 200' long and 150' wide and the 8' high ceiling is smooth and flat. A spot type heat detector

has been selected that is listed for a 50' maximum spacing between detectors. According to NFPA 72

how many detectors will be needed to protect this room?

Page 1/20

,EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024




x = - Answer✔✔-12


According to NFPA 72 the minimum number of restorable fixed temperature spot type heat detectors

that must be tested during each annual test is?




(NFPA 72 14.4.4.5.1) - Answer✔✔-Two detectors or more on each initiating device circuit


According to NFPA 72 how many spot type heat detectors are required for a space that is 80' long and 55

floor wide with a smooth 10' ceiling? the detector is listed for a maximum space between detectors of

30' - Answer✔✔-6


What color code requirement for a spot type heat detector rated at 200゚F - Answer✔✔-White (NFPA 72,

Table 17.6.2.1)


Unless otherwise recommended by the manufacturers published instructions single and multiple

stations smoke alarms installed in one and 2 family dwellings shall be replaced every - Answer✔✔-10

years from the day-of manufacture. (NFPA 72, 14.4.7.1)


Fire alarm cables are permitted to be strapped to conduit to support the cable - Answer✔✔-False (NEC

760.143)


Where non power limited wiring is installed exposed it must be mechanically protected within_____of

the finished floor - Answer✔✔-7' ft


Fire-Warning equipment to be installed in residential occupancies shall produce the audible emergency

evacuation signal described in - Answer✔✔-ANSI S3.41

Page 2/20

, EMILLYCHARLOTTE 2024/2025 ACADEMIC YAER ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISH SEPTEMBER 2024


According to NFPA 72, visible notification appliance for non-sleeping areas must be mounted between

___ and ___ inches above the finished floor - Answer✔✔-80 & 96


If system impairment occurs, the owner must be notified ___ within ___ - Answer✔✔-in writing & within

24 hours


A 20 X 20' ft room with a 20'ft high ceiling requires at a minimum a ___ ceiling mounted strobe -

Answer✔✔-30 candela


According to NFPA 72, a 40 x 40'ft room or area with a 10'ft ceiling is best covered by a ___ cd visible

notification appliance, centered on one wall. - Answer✔✔-60


Conductors returning to the fire alarm control panel (FACP) from the last field device on the circuit might

indicate a _____ circuit - Answer✔✔-Class A


Secondary power supplies for an emergency voice/alarm communication fire alarm system shall be

capable of operating for minimum of ___ of standby followed by ___ of alarm. - Answer✔✔-24 hrs & 15

mins


The fire alarm system primary power branch circuit disconnecting means must be ___ in color. -

Answer✔✔-Red


The secondary power supply for protected premises shall automatically provide power within ___

seconds when primary power fails. - Answer✔✔-10 seconds


Under which of the following conditions shall spot-type smoke detectors NOT be installed? - Answer✔✔-

When the temperature is over 100*F


Who is responsible for maintaining Personal Protective Equipment? - Answer✔✔-YOU, the employee

Page 3/20

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
EmillyCharlotte Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
94
Member since
1 year
Number of followers
4
Documents
11951
Last sold
2 days ago
ALL-MAJOR.

On this page, you find all documents, package deals, and flashcards offered by seller Emilly Charlotte.

3.6

20 reviews

5
7
4
6
3
2
2
2
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions