Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 40 pages
Exam (elaborations)

Globus 201 Final Exam Questions and Essays with 100% Correct Answers

Document preview thumbnail
Preview 4 out of 40 pages

Globus 201 Final Exam Questions and Essays with 100% Correct Answers

Content preview

Globus 201 Final Exam Questions and Essays
with 100% Correct Answers
INDEPENDENCE MIS: The spacer should always be implanted as far posterior as possible so that
the positive stop on the Triple Barrel Anchor Guide contacts the vertebrae.
Select the correct response:
True

False - ✔️✔️False


INDEPENDENCE MIS: How can you ensure an anchor is correctly loaded into the Triple Barrel
Anchor Guide?
Select the correct response:
Lay instrument flat on the table
Use the laser marked anchor indicator as a guide to the anchor orientation
Use your thumb to secure the anchor in instrument
Confirm that a click was felt or heard
Confirm that anchors are fully seated

All of the above - ✔️✔️All of the above


INDEPENDENCE MIS: Each anchor is to be incrementally impacted one at a time, using
fluoroscopy to monitor the advancement of each anchor.
Select the correct response:
True

False - ✔️✔️True


INDEPENDENCE MIS: The Triple Barrel Anchor Guide will not disengage from the spacer. What
can you advice the surgeon to do?
Select the correct response:

,Confirm the Hex Driver is fully seated into the Threaded Rod hex hole
Rotate Hex Driver counterclockwise while simultaneously withdrawing the instrument, gently
rocking left/right as needed.

All of the above - ✔️✔️All of the above


INDEPENDENCE MIS: If an Anchor needs to be removed from the spacer once implanted, what
should you advise the surgeon before the removal?
Select the correct response:
Confirm that the set screw has been rotated to the open position
Confirm that the Freehand Inserter is attached to the spacer
Confirm that the Anchor Removal Tool is fully threaded into the Anchor

Both 1 and 3 - ✔️✔️Both 1 and 3


Which of the following sets do you need to do a MAGNIFY-S case?
Select the correct response:
9126.9101- MAGNIFY™-S Instrument Set
9126.9102- MAGNIFY™-S 25x31 Implant Set
9126.9103- MAGNIFY™-S 26x34 Implant Set
9126.9104- MAGNIFY™-S 29x39 Implant Set
925.905- ALIF Instrument Set
925.906- ALIF Trials
925.907- ALIF Bone Screws
925.901- Anterior Disc Prep I
925.902- Anterior Disc Prep II

All of the above - ✔️✔️All of the above


MAGNIFY-S: Select the inserter(s) that allow placement of screw(s) with inserter attached to
implant?

,Select the correct response(s):
Lateral Inserter
Offset Inserter

Midline Inserter - ✔️✔️Lateral inserter, offset inserter


MAGNIFY-S: When contracting the implant DO NOT use excess torque as implant integrity can
be compromised.
Select the correct response:
True

False - ✔️✔️True


MAGNIFY-S: How many revolutions of Torque Limiting Hex Driver will result in 1mm expansion?
Select the correct response:
1
2
0.5

1.5 - ✔️✔️1.5


MAGNIFY-S: Can you pack into bone screw holes?
Select the correct response:
No

Yes - ✔️✔️No


MAGNIFY-S: The midline inserter does not attach to implant if set screws are in ________
________.
Select the correct response:
Locked position

, Unlocked positon - ✔️✔️Locked


Which of the following is MONUMENT approved for?
Select the correct response:
MONUMENT is approved as a vertebral body replacement device
MONUMENT is approved for the thoracic spine
MONUMENT is approved as a stand-alone interbody fusion device
MONUMENT is approved as an interbody fusion device with supplemental fixation (i.e. pedicle
screws, facet fixation) from L2-S1 - ✔️✔️MONUMENT is approved as an interbody fusion device
with supplemental fixation (i.e. pedicle screws, facet fixation) from L2-S1


Which of the following is MONUMENT approved for?
Select the correct response:
Grade 1 spondylolisthesis
Grade 2 spondylolisthesis
Grade 3 spondylolisthesis
Grade 4 spondylolisthesis

Grade 5 spondylolisthesis - ✔️✔️Grade 1


How many millimeters of translation can MONUMENT achieve?
Select the correct response:
10mm
8mm
6mm

4mm - ✔️✔️8mm


MONUMENT®: One complete revolution of the Implant Reduction Driver is?
Select the correct response:

Document information

Uploaded on
October 3, 2024
Number of pages
40
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$14.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Examcheatcode
5.0
(1)
Sold
4
Followers
1
Items
1236
Last sold
1 year ago



Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions