Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 2 out of 8 pages
Exam (elaborations)

NFPA 25 2024 NICET Lvl 1 Test / Revised Questions and Answers / Sure A+

Document preview thumbnail
Preview 2 out of 8 pages

A ___ drain is located beyond a sectional control valve that drains only a portion of the system - Sectional; 3.3.10.2 A building has three different types of sprinklers how many sprinkler wrenches are required to be kept on premises - 3; 5.2.1.4(2) A class one standpipe system is a system that provides ___ hose connections to water supply used by fire departments - 2 1/2 inch; 13.3.43.1 A permanently, marked informational sign shall be placed at the ___ supplying the antifreeze loop, dry system, pre-action system, or auxiliary systems control valve - System control riser; 4.1.9.1 A test of a closed piping system and it's appurtenances consisting of subjecting the piping to an increased internal pressure for a specified duration to verify system. Integrity and system leakage rates is defined as? - Hydrostatic test; 3.3.20 A test of a closed piping system and its attached appurte

Content preview

NFPA 25 M1L1-3 Midterm Exam /
Revised Questions and Answers / Sure
A+
___ is the most universal agent used for fire control and extinguishment. - Water



A "critical deficiency" is a deficiency that may have a(n) ___ effect on the ability of the fire protection
system to function as intended in a fire event. - Not serious or immediate



A code tells the user ___ something must be done. - what and when



A compartment is best described by which of the following statements? - Not A confined space or
A space with no means of egress



A fire protection system that is designed to protect physical assets or the structure is designed to be ___
when compared to a system designed for life safety. - more robust



A higher level of oxygen supports an increased oxidation process and results in a(n) ___ rate of burning.
- increased



A missing control valve sign is an example of a(n) ___ on a water-based fire protection system. -
non-critical deficiency



Any abnormality observed during inspection or testing must be reported promptly to the ___. -
owner



Automatic and manual water-based systems are never used together. - False



Carbon Dioxide at a concentration of ___ percent can result in a loss of consciousness in just a few
minutes. - Not ten

, Class A fires are expected to deliver similar amounts of heat release and burning rates. - True only
if the type of combustible and quantities are the same between fires.



Control mode sprinkler systems are designed for final extinguishment of the fire to be done ___. -
manually



Deluge sprinkler systems must have a detection system as a part of the design. - True



Fire is best described as a ___ that requires a fuel source, sufficient oxygen, and heat. -
exothermic chemical reaction



Fires are classified to assist in determining the most efficient ___ for controlling, suppressing, or
extinguishing the fire. - agent



Foam systems are typically only used with which of the following class fires? - Not Classes A and K
or class A



Heat of combustion is the amount of ___ that is stored in a quantity of material. - heat



Ignition occurs when sufficient ___ are liberated from the surface of a material to be within an ignitable
range. - combustible vapors



Inspection, testing, and maintenance activities must be conducted in accordance with ___ safety
regulations. - applicable



It is critical that a contractor who performs inspections and tests have a(n) ___ with the owner regarding
the scope of the services to be provided. - contract



Most fire sprinkler systems are designed to ___ a fire. - Not contain or suppress/ extinguish or
contain

Document information

Uploaded on
September 17, 2024
Number of pages
8
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
$8.49

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Lucindajohns
5.0
(2)
Sold
14
Followers
8
Items
2248
Last sold
3 months ago


Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions