Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

URR Abdomen Physics & Clinical Questions And Answers Latest Updates

Rating
-
Sold
-
Pages
16
Grade
A+
Uploaded on
16-09-2024
Written in
2024/2025

Color Doppler demonstrates (x2) - average velocity & direction of flow Which artifacts will be seen with needles? (x3) - - Propagation speed artifact - Reverberation AKA resonance artifact - Bayonet artifact What happens if you decrease the color threshold? - reduce the color displayed - color threshold AKA priority - increase threshold if you don't see enough color If the entire image is too bright, what do you do first? - decrease the output power reverberation artifact due to gas production AKA _______ artifact - resonance artifact lower frame rate = increased/degraded temporal resolution - degraded temporal resolution For renal artery doppler evaluation, the angle should be _____. For intraparenchymal arteries, the angle should be _____. - - main RA = 60 - intraparenchymal = 20 Increasing _____ will most improve the ability to properly trace the contour of Doppler waveform. - Sweep speed A simple cyst could have artifactual debris in it in case of (x2) - - short distance from the transducer - volume averagingA contrast agent that consists of a cellulose suspension can better visualize which organ? - pancreatic tail Which artifact occurs when sampling vessels adjacent to a highly reflective structure like a bone? - Cross talk - mirror image of the waveform on the other side of the baseline Harmonic imaging increase (x3) and decrease (x3) - Increase - spatial resolution - contrast resolution - signal to noise ratio Decrease - reverberation - beam aberration - side lobes If you have trapezoidal field of view on linear array, which resolution are you degrading? - lateral resolution - Trapezoidal = 台形 - wider beams = less lateral resolution The number of lines of information used to create the color displayed on the image is called - Packet size - increase packet size = increase color display Sample angle controls the amount of color fill in a vessel evaluated with color Doppler. T/F - True - angle DOES matter to color fillingFile type for PACS system - DICOM = Digital Imaging & Communications in Medicine Name of transducer; order of the term in the name - 1. Shape of the transducer comes first 2. phased/sequential comes second e.g. - sector phased array - linear sequential array The bayonet artifact is - a type of propagation speed error, the tip of the needle appears curved When you are scanning MSK, you see this artifact; if the transducer is not parallel to the _____, it falsely appears hyperechoic/hypoechoic. - Anisotropy - scanning tendon - appears falsely hypoechoic (hypo=abnormal) - rock the transducer to make it parallel to the tendon How do you reduce the clutter/flash on a color Doppler image? - Decrease color priority/threshold In case of contrast live ultrasound, the mechanical index should be ______. Then turn on _____, and focal zone should be placed at ______ - - Mechanical Index = low (1.0) → prevent cavitation of microbubbles - turn on harmonics - focal zone at the area of interest Specular reflection occurs with - a large smooth structure = diaphragm - echogenic appearanceWhich vessel do you need to use angle correction during Doppler evaluation if you are evaluating a liver transplant? - Hepatic arteries & portal veins ______ adjusts the dynamic range AKA number of shades of gray on the image; when it decrease, dynamic range will get smaller = more black and white image. - Compression - Compression↓ = Dynamic↓ = shades of gray↓ = more black and white If you overestimate the angle between the beam and the blood flow, what happen to the velocity? - overestimate velocity - more angle = less cosine = more velocity - Shift = 2x f(TX) x V(blood) x cosθ

Show more Read less
Institution
URR Abdomen Physics & Clinical
Course
URR Abdomen Physics & Clinical

Content preview

URR Abdomen Physics & Clinical
Color Doppler demonstrates (x2) - average velocity & direction of flow



Which artifacts will be seen with needles? (x3) - - Propagation speed artifact

- Reverberation AKA resonance artifact

- Bayonet artifact



What happens if you decrease the color threshold? - reduce the color displayed

- color threshold AKA priority

- increase threshold if you don't see enough color



If the entire image is too bright, what do you do first? - decrease the output power

reverberation artifact due to gas production AKA _______ artifact - resonance artifact



lower frame rate = increased/degraded temporal resolution - degraded temporal resolution



For renal artery doppler evaluation, the angle should be _____. For intraparenchymal arteries, the angle
should be _____. - - main RA = <60

- intraparenchymal = <20



Increasing _____ will most improve the ability to properly trace the contour of Doppler waveform. -
Sweep speed



A simple cyst could have artifactual debris in it in case of (x2) - - short distance from the
transducer

- volume averaging

,A contrast agent that consists of a cellulose suspension can better visualize which organ? -
pancreatic tail



Which artifact occurs when sampling vessels adjacent to a highly reflective structure like a bone? -
Cross talk

- mirror image of the waveform on the other side of the baseline




Harmonic imaging increase (x3) and decrease (x3) - Increase

- spatial resolution

- contrast resolution

- signal to noise ratio



Decrease

- reverberation

- beam aberration

- side lobes



If you have trapezoidal field of view on linear array, which resolution are you degrading? - lateral
resolution

- Trapezoidal = 台形

- wider beams = less lateral resolution



The number of lines of information used to create the color displayed on the image is called -
Packet size

- increase packet size = increase color display



Sample angle controls the amount of color fill in a vessel evaluated with color Doppler. T/F - True

- angle DOES matter to color filling

, File type for PACS system - DICOM = Digital Imaging & Communications in Medicine



Name of transducer; order of the term in the name - 1. Shape of the transducer comes first

2. phased/sequential comes second



e.g.

- sector phased array

- linear sequential array



The bayonet artifact is - a type of propagation speed error, the tip of the needle appears curved



When you are scanning MSK, you see this artifact; if the transducer is not parallel to the _____, it falsely
appears hyperechoic/hypoechoic. - Anisotropy

- scanning tendon

- appears falsely hypoechoic (hypo=abnormal)

- rock the transducer to make it parallel to the tendon



How do you reduce the clutter/flash on a color Doppler image? - Decrease color
priority/threshold



In case of contrast live ultrasound, the mechanical index should be ______. Then turn on _____, and
focal zone should be placed at ______ - - Mechanical Index = low (<1.0) → prevent cavitation of
microbubbles

- turn on harmonics

- focal zone at the area of interest



Specular reflection occurs with - a large smooth structure = diaphragm

- echogenic appearance

Written for

Institution
URR Abdomen Physics & Clinical
Course
URR Abdomen Physics & Clinical

Document information

Uploaded on
September 16, 2024
Number of pages
16
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$8.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Thumbnail
Package deal
URR EXAM BUNDLE GRADED A+
-
9 2024
$ 75.61 More info

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ACADEMICMATERIALS City University New York
View profile
Follow You need to be logged in order to follow users or courses
Sold
614
Member since
2 year
Number of followers
185
Documents
10570
Last sold
1 week ago

4.0

99 reviews

5
54
4
13
3
21
2
3
1
8

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions