URR mock exam 1 SPI Questions And Answers Rated A+

Rating
-
Sold
-
Pages
26
Grade
A+
Uploaded on
16-09-2024
Written in
2024/2025

The doppler shift is 5000 Hz. The pulse repetition frequency is 9000 Hz. Which of the following is true? A. peak pressure gradient is 36mmHg B. range ambiguity will occur C. aliasing will occur D. the peak velocity is equal to 2 m/s - ️️C. aliasing will occur When evaluating a suspected arterial stenosis, a doppler angel of ____ degrees will produce the most accurate flow velocity. A. 0 B. 30 C. 60 D. 90 - ️️A. 0 Spatial resolution is: A. the minimum reflector separation required to produce separate echos. B. highest with linear phased arrays. C. the weakest reflected signal the transducer can receive D. another term for slice thickness resolution - ️️A. the minumum reflector separation required to produce echos Which of the following Doppler angles would lead to the most significant error in estimation of the flow velocity? A. 25 B. 45 C. 65 D. 80 - ️️D. 80 which of the following necessary machine setting with performing a contrast evolution of the heart? A. harmonic imaging off B. mechincal index set to 0.3 or lower C. mechanical index set to 1.0 or greater D. Low PRF color Doppler setting - ️️B. mechanical index set to 0.3 or lower How many pulses are needed per scan line in order to generate a single frame of color Doppler? A. 6 B. 1 C. 16 D. 3 - ️️D. 3The rectus abdominis muscles are associated with ____, while the diaphragm is associated with ______. A. shadowing, enhancement B. comet tail, ring down C. refractive shadowing, lobe artifact D. refraction artifact, mirror image artifact - ️️D. refraction artifact, mirror image artifact ____ is defined as specific area or location where Doppler shift info is being obtained. A. spectral broadening B. nyquist limit C. sample volume D. spectral window - ️️C. sample volume Increasing the angle of electronic steering causes _____ production of lobe artifact. A. increased B. decreased C. no change D. limited - ️️A. increased Put the following media in order from lowest to highest according to their acoustic impedance: Bone Air Liver Blood - ️️Air, blood, liver, bone Even and odd harmonic frequencies are created by: A. alternating current to different piezoelectric elements in the transducer array B. non-linear sound wave propagation C. variable timing of the firing of the piezoelectric elements D. turbulent flow in the blood vessel - ️️B. non-linear sound wave propagation what type of transducer array has the fewest numbers of elements? A. linear phased array B. annular array C. curvilinear sequential array D. mechanical transducer - ️️B. annular array ______ artifact is caused by refraction and results in subtle image degradation. A. comet tail B. scatter C. misregistration D. multipath - ️️D. multipathWhich of the following will improve lateral resolution at all depths on the image? A. dynamic transmit focusing B. dynamic receive focusing C. decrease probe frequency D. use >3 focal zones - ️️B. dynamic receive focusing which of the following units is used to describe beam intensity? A. dB/cm/MHz B. dB C. mW/cm 2 D. mW - ️️C. mW/cm 2 which of the following parameters cannot be evaluated by the AIUM test object? A. depth calibration B. distance calibration C. gray scale D. azimuthal resolution - ️️C. gray scale

Show more Read less
Institution
URR Mock SPI
Course
URR mock SPI










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
URR mock SPI
Course
URR mock SPI

Document information

Uploaded on
September 16, 2024
Number of pages
26
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Content preview

URR mock exam 1 SPI
The doppler shift is 5000 Hz. The pulse repetition frequency is 9000 Hz. Which of the
following is true?
A. peak pressure gradient is 36mmHg
B. range ambiguity will occur
C. aliasing will occur
D. the peak velocity is equal to 2 m/s - ✔️✔️C. aliasing will occur

When evaluating a suspected arterial stenosis, a doppler angel of ____ degrees will
produce the most accurate flow velocity.
A. 0
B. 30
C. 60
D. 90 - ✔️✔️A. 0

Spatial resolution is:
A. the minimum reflector separation required to produce separate echos.
B. highest with linear phased arrays.
C. the weakest reflected signal the transducer can receive
D. another term for slice thickness resolution - ✔️✔️A. the minumum reflector
separation required to produce echos

Which of the following Doppler angles would lead to the most significant error in
estimation of the flow velocity?
A. 25
B. 45
C. 65
D. 80 - ✔️✔️D. 80

which of the following necessary machine setting with performing a contrast evolution of
the heart?
A. harmonic imaging off
B. mechincal index set to 0.3 or lower
C. mechanical index set to 1.0 or greater
D. Low PRF color Doppler setting - ✔️✔️B. mechanical index set to 0.3 or lower

How many pulses are needed per scan line in order to generate a single frame of color
Doppler?
A. 6
B. 1
C. 16
D. 3 - ✔️✔️D. 3

,The rectus abdominis muscles are associated with ____, while the diaphragm is
associated with ______.
A. shadowing, enhancement
B. comet tail, ring down
C. refractive shadowing, lobe artifact
D. refraction artifact, mirror image artifact - ✔️✔️D. refraction artifact, mirror image
artifact

____ is defined as specific area or location where Doppler shift info is being obtained.
A. spectral broadening
B. nyquist limit
C. sample volume
D. spectral window - ✔️✔️C. sample volume


Increasing the angle of electronic steering causes _____ production of lobe artifact.
A. increased
B. decreased
C. no change
D. limited - ✔️✔️A. increased

Put the following media in order from lowest to highest according to their acoustic
impedance:
Bone
Air
Liver
Blood - ✔️✔️Air, blood, liver, bone

Even and odd harmonic frequencies are created by:
A. alternating current to different piezoelectric elements in the transducer array
B. non-linear sound wave propagation
C. variable timing of the firing of the piezoelectric elements
D. turbulent flow in the blood vessel - ✔️✔️B. non-linear sound wave propagation

what type of transducer array has the fewest numbers of elements?
A. linear phased array
B. annular array
C. curvilinear sequential array
D. mechanical transducer - ✔️✔️B. annular array

______ artifact is caused by refraction and results in subtle image degradation.
A. comet tail
B. scatter
C. misregistration
D. multipath - ✔️✔️D. multipath

, Which of the following will improve lateral resolution at all depths on the image?
A. dynamic transmit focusing
B. dynamic receive focusing
C. decrease probe frequency
D. use >3 focal zones - ✔️✔️B. dynamic receive focusing

which of the following units is used to describe beam intensity?
A. dB/cm/MHz
B. dB
C. mW/cm 2
D. mW - ✔️✔️C. mW/cm 2

which of the following parameters cannot be evaluated by the AIUM test object?
A. depth calibration
B. distance calibration
C. gray scale
D. azimuthal resolution - ✔️✔️C. gray scale


which of the following system adjustments would increase the size of the spectral
window?
A. decreasing rejection
B. changing from a 2mm to 4mm sample size
C. changing from a 4mm to 2mm sample size
D. tortuous vessel - ✔️✔️C. changing from a 4mm to 2mm sample size

In read magnification, image size and _____ increases. In write magnification, image
size and ____ increases.
A. pixel size, number of pixels
B. number of pixels, pixel size
C. reflection amplitude, transmitted amplitude
D. frame rate, time of frame production - ✔️✔️A. pixel size, number of pixels

If the lines per frame increases and the depth remains the same, what other system
parameter must change for sound wave production?
A. propagation speed of the sound produced
B. signal to noise ratio
C. frequency
D. PRF - ✔️✔️D. PRF

How can you adjust elevation focus to a more superficial location in a 1D array
transducer?
A. scan the breast from a later approach
B. use a stand off pad
C. change the short axis focus setting on the console

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
ACADEMICMATERIALS City University New York
View profile
Follow You need to be logged in order to follow users or courses
Sold
562
Member since
2 year
Number of followers
186
Documents
10590
Last sold
3 days ago

4.1

95 reviews

5
53
4
11
3
21
2
3
1
7

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions