100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

Chapter 8 – Radon Practice Questions and Answers | 100% Pass

Rating
-
Sold
-
Pages
6
Grade
A+
Uploaded on
16-09-2024
Written in
2024/2025

Chapter 8 – Radon Practice Questions and Answers | 100% Pass A client expresses concern because, during a 7-day charcoal canister short-term test, a brief thunderstorm passes over the home. Which of the following would be the MOST APPROPRIATE response to give this client? - Answer️️ -Since the measurement period is 7 days, the test will still be valid. A post-mitigation radon measurement device should be placed: - Answer️️ -in the same location as the pre-mitigation test device. According to EPA Measurement Protocols, a single radon test is acceptable for a real estate transaction under which of the following conditions? - Answer️️ -A 48-hour measurement with an active continuous monitor which can integrate and record a new result hourly or less. According to the simultaneous test option for real estate transactions, when one result is greater than 4 pCi/L and the other result is less than 4 pCi/L, a re-test is recommended if the: - Answer️️ -higher result is greater than twice the lower result. Follow-up measurements should always be taken: - Answer️️ -in the same location as the initial measurement. For passive (no pump) continuous monitors, the first 4 hours of data are discarded to allow: - Answer️️ -the instrument to reach equilibrium. ©SOPHIABENNETT EXAM SOLUTIONS_2024/2025 Tuesday, September 3, 2024 10:30 AM Page | 2 How close to one another must two charcoal detectors be placed if they are to be considered collocated test devices for real estate testing? - Answer️️ -4 inches In a real estate test, two activated charcoal canisters measured 1.5 pCi/L and 5.5 pCi/L after exposure for 48 hours at opposite ends of an occupied basement. The client should be informed that: - Answer️️ -When two collocated passive devices (4 inches apart) are on opposite sides of the 4.0 pCi/L guidance the results should not vary more than 2-fold. In this case one is above 4 and the other is below 4 AND 5.5 is more than two times the lower result of 1.5. Because of this wide variation the results are to be thrown out and the test repeated. The correct answer is: The two results are too far apart and

Show more Read less
Institution
Radon
Course
Radon









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Radon
Course
Radon

Document information

Uploaded on
September 16, 2024
Number of pages
6
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

©SOPHIABENNETT
EXAM_SOLUTIONS GUARANTEED SUCCESS 2024/2025 ACADEMIC YEAR




©SOPHIABENNETT 9/3/24 2024/2025

, ©SOPHIABENNETT EXAM SOLUTIONS_2024/2025 Tuesday, September 3, 2024 10:30 AM



Chapter 8 – Radon Practice Questions
and Answers | 100% Pass


A client expresses concern because, during a 7-day charcoal canister short-term test,

a brief thunderstorm passes over the home. Which of the following would be the MOST

APPROPRIATE response to give this client? - Answer✔️✔️-Since the measurement

period is 7 days, the test will still be valid.


A post-mitigation radon measurement device should be placed: - Answer✔️✔️-in the

same location as the pre-mitigation test device.

According to EPA Measurement Protocols, a single radon test is acceptable for a real

estate transaction under which of the following conditions? - Answer✔️✔️-A 48-hour

measurement with an active continuous monitor which can integrate and record a new

result hourly or less.

According to the simultaneous test option for real estate transactions, when one result is

greater than 4 pCi/L and the other result is less than 4 pCi/L, a re-test is recommended

if the: - Answer✔️✔️-higher result is greater than twice the lower result.

Follow-up measurements should always be taken: - Answer✔️✔️-in the same location as

the initial measurement.

For passive (no pump) continuous monitors, the first 4 hours of data are discarded to

allow: - Answer✔️✔️-the instrument to reach equilibrium.




Page | 1

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
SophiaBennett Howard Community College
View profile
Follow You need to be logged in order to follow users or courses
Sold
131
Member since
1 year
Number of followers
5
Documents
9104
Last sold
1 week ago
EXAM GAME-CHANGER

Exam Questions and Answers Section : Study Like a Pro, Study Smart, Study with Sophia.

3.7

26 reviews

5
10
4
5
3
7
2
1
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Frequently asked questions